• Title/Summary/Keyword: Limit of Detection

Search Result 2,421, Processing Time 0.046 seconds

Determination of the Levels of Bisphenol A Diglycidyl Ether (BADGE), Bisphenol F Diglycidyl Ether (BFDGE) and Their Reaction Products in Canned Foods Circulated at Korean Markets (캔 제품의 bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) 유도체 및 분해산물 분석법)

  • Kim, Hee-Yun;Lee, Jin-Sook;Cho, Min-Ja;Yang, Ji-Yeon;Baek, Ji-Yun;Cheong, So-Young;Choi, Sun-Hee;Kim, Young-Seon;Choi, Jae-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE) were obtained by a polymerization reaction of epichlorohydrin (ECH) with bisphenol A (BPA) or bisphenol F (BPF). These compounds are commonly used as monomers or additives such as a polymerization stabilizer and a hydrochloric acid scavenger of epoxy resin, polyvinyl chloride (PVC)-containing organosols and polyester lacquers, that are applied to the internal surface of most canned foods to impart chemical resistance. The unreacted BADGE, BFDGE and their reaction products migrating from epoxy resin, PVC-containing organosol and/or polyester lacquer-based food packaging materials into the foods have recently become an issue of great concern because of increased customer demand for safety. This study was conducted to develop a rapid and sensitive simultaneous analysis method based on HPLC/FLD and HPLC/APCI-mass and to evaluate the concentration of BADGE, BFDGE and their metabolites, BADGE $H_2O$, BADGE $2H_2O$, BADGE HCl, BADGE 2HCl, BADGE HCl $H_2O$, BFDGE $H_2O$, BFDGE $2H_2O$, BFDGE HCl, BFDGE 2HCl and BFDGE HCl $H_2O$ for 133 canned food samples. The method provided a linearity of 0.9997-0.9999, a limit of detection of $0.01-0.13\;{\mu}g/mL$, a limit of quantitation of $0.03-0.44\;{\mu}g/mL$ and a recovery (%) of 85.64-118.18. The number of samples containing BADGE, BFDGE or their metabolites were: 28/133 (21.1%), with levels of 0.400-0.888 mg/kg being observed for aqueous foods (19/133) and 0.093-0.506 mg/kg being observed for oily foods (9/133).

Rediscussion of the Architectural construction measure of the Sacheonwangsa Temple in Silla (신라사천왕사건축(新羅四天王寺建築)의 조영척도(造營尺度) 재론(再論))

  • Lee, Jeong-Min;Mizoguchi, Akinori
    • Journal of architectural history
    • /
    • v.28 no.5
    • /
    • pp.43-58
    • /
    • 2019
  • After the study of Fujishima Gaijiro(1930), although it is common to see that the Tang-ruler(唐尺) was used in the construction of the Silla Sacheonwangsa temple(679), the basis of the discrimination of the construction measure and the detection of the unit length is not actually sufficient since conventional research was done before the excavation. The study was based on archaeological results, which was secured through the excavation research(2006~2012) of the temple site in recent years, to determine the construction measure and try to detect the unit length. In the analysis of the measured value of the ruins, the numerical data were obtained through measurements on drawings of the ruins, the tendency of conversion measure's number appearing by dividing each unit length of the Goguryeo-ruler(高句麗尺) and Tang-ruler within a certain range was compared from the Wansu-je(完數制) viewpoint. The research results are summarized as follows : 1)As a result of the analysis of the distance between the site's center, the case that conversion Cheok's(尺) number is converged to the unit of Jang(丈) within the range of unit length expresses three times more in Tang-ruler, and it is confirmed that a simple multiple relationship based on the unit of Jang is established between conversion Cheok's number. 2)As a result of analysis of Bokan(梁間) of the each Corridor site and the measured value of the stonework ruins, it could be confirmed that appears overwhelmingly in the Tang-ruler when conversion Cheok's number becomes an integer within the range of unit length. The results of the analysis are judged to be a clear basis for viewing the Tang-ruler as the construction measure of the Sacheonwangsa temple. 3)The estimated unit lengths of the construction measure that were obtained from the analysis of the distance between the site'scenter, the foundation stone center distance of the building site and the measured value of the stonework ruins are slightly different. There is a limit to the verification of the construction error about this, however it is difficult to specify, it is mentioned 294.37mm which is obtained from the analysis of the distance between the site's center.

Biogenic-Amine Contents of Korean Commercial Salted Fishes and Cabbage Kimchi (젓갈류 및 배추김치에서의 바이오제닉 아민류 함량 조사 연구)

  • Shin, Sang-Woon;Kim, Young-Sug;Kim, Yang-Hee;Kim, Han-Taek;Eum, Kyoung-Suk;Hong, Se-Ra;Kang, Hyo-Jeong;Park, Kwang-Hee;Yoon, Mi-Hye
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.1
    • /
    • pp.13-18
    • /
    • 2019
  • We determined the contents of 11 biogenic amines in 20 types of cabbage kimchi, 10 types of fish sauce, and 40 types of salted fish purchased from small- and medium-sized grocery stores in Gyeonggi-Do, Republic of Korea, from June to October 2017. The content of each of the biogenic amines in the various types of cabbage kimchi was slightly lower than that in detection amounts of each of the 10 types of biogenic amines and the values reported by Joe et al. The histamine content of all five types of anchovy sauce was lower than the limit set by the European Union (400 mg/kg), but that of three of the five types of sand lance sauce was higher. Analyzing the ratios of the contents of five highly toxic biogenic amines to those of the 11 biogenic amines yielded no quantitative correlation. The estimated daily intake of the five highly toxic biogenic amines in cabbage-kimchi and fermented fish was ${\leq}6mg$.

Antioxidant activities and Validation of Analytical Method of Marker compounds in strawberry fruits from various cultivars (딸기 품종별 추출물의 항산화활성 및 지표성분 밸리데이션)

  • Yong, Ye Seul;Lee, Songmi;Byun, Na-Young;Sun, Sangouk;Kim, Min-Jung;Jang, Seo Woo;Jang, Won Suk;Lee, Sun Yi;Yim, Soon-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.517-523
    • /
    • 2019
  • In this study, we investigated antioxidant capacity of 20 strawberry extract using the DPPH and ABTS assay and HPLC-DAD validation method. The total polyphenolic and flavonoids contents of 20 strawberry extracts were 22.77-107.61 mg TAE/100 g FW and 17.58-44.12 mg QE/100 g FW. The Aiberry and Elie star showed the highest total polyphenol and flavonoid contents, respectively. The DPPH radical scavenging activity of what was 1540.6-1124.0 μmol TEAC/100 g FW and Derunoka showed the highest activity. The ABTS radical scavenging activity was 6352.3-4592.3 μmol TEAC/100 g FW and FA23 showed the highest activity. The HPLC-DAD method for the quantitation of ellagic acid results showed high linearity in various concentration ranges, and the limit of detection was 2.35 μg/mL. The limit of quantification was 7.12 μg/mL. Relative standard deviation values from intra-and inter-day precision were less than 5.31%. Recovery rate at 10, 50, and 100 μg/mL, respectively, were 100.0-101.0% with relative standard deviation (RSD) values less than 5.30%. These results provide viable information for the validation of antioxidant capacity in strawberry fruits.

Development and Validation of Analytical Method for Determination of Biphenyl Analysis in Foods (식품 중 비페닐 분석법 개발 및 유효성 검증)

  • Kim, Jung-Bok;Kim, Myung-Chul;Song, Sung-Woan;Shin, Jae-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.4
    • /
    • pp.459-464
    • /
    • 2017
  • Biphenyl is used as an intermediate in the production of crop protection products, a solvent in pharmaceutical production, and as a component in the preservation of citrus fruits in many countries. Biphenyl is not authorized for use and also does not have standards or specifications as a food additive in Korea. National and imported food products are likely to contain biphenyl. Therefore, control and management of these products is required. In this study, a simple analytical method was developed and validated using HPLC to determine biphenyl in food. These methods are validated by assessing certain performance parameters: linearity, accuracy, precision, recovery, limit of detection (LOD), and limit of quantitation (LOQ). The calibration curve was obtained from 1.0 to $100.0{\mu}g/mL$ with satisfactory relative standard deviations (RSD) of 0.999 in the representative sample (orange). In the measurement of quality control (QC) samples, accuracy was in the range of 95.8~104.0% within normal values. The inter-day and inter-day precision values were less than 2.4% RSD in the measurement of QC samples. Recoveries of biphenyl from spiked orange samples ranged from 92.7 to 99.4% with RSD between 0.7 and 1.7% at levels of 10, 50, and $100{\mu}g/mL$. The LOD and LOQ were determined to be 0.04 and $0.13{\mu}g/mL$, respectively. These results show that the developed method is appropriate for biphenyl identification and can be used to examine the safety of citrus fruits and surface treatments containing biphenyl residues.

Characteristics of Groundwater, Sewage Water and Stream Water Contamination Based on VOCs Concentration Around Ulsan, Korea (울산지역 지하수, 하수 및 하천수의 VOCs 오염특성)

  • Cho, Byong-Wook;Yun, Uk;Im, Hyun-Chul;Sung, Ig-Hwan;Jang, Woo-Seog
    • Economic and Environmental Geology
    • /
    • v.38 no.1
    • /
    • pp.57-65
    • /
    • 2005
  • To investigate the characteristics of the volatile organic compounds (VOCs) concentration in the groundwater around Ulsan, Korea, 168 groundwaters, 12 stream waters, and 6 sewage waters were analyzed for 61 VOCs. Results showed that VOCs were not detected in stream waters and total VOCs concentration in 5 sewage waters was in the range of ND-22.3 ${\mu}$g/L. In 78 groundwater samples more than one VOCs were detected and VOCs concentration of the samples ranged from 0.1 ${\mu}$g/L to 387.1 ${\mu}$g/L. However, VOCs concentration of 66 samples out of 78 samples showed less than 10 ${\mu}$g/L and that of only 6 samples exceeded Korea drinking water limit (KDWL). 42 VOCs detected from the 168 groundwaters were 14 aromatic hydrocarbons out of 25, 27 chlorinated aliphatic hydrocarbons out of 35, and methyl tert-butyl ether (MTBE). Detection rate of each VOCs in the groundwaters was as follows: chloroform in 43 samples (25.6%), methylene chloride in 36 samples (21.4%), TCE in 26 samples (15.5%), 1,1-dichloroethane in 19 samples (1.3%), PCE in 16 samples (9.5%), cis-1,2-DCE in 15 samples (8.9%), and toluene in 14 samples (8.3%). Even though VOCs concentration in the groundwaters of the study area is still low, the city is expanding and the drinking water limit is becoming strict, and therefore continuous monitoring is necessary.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fexofenadine in Human (테르페나딘 체내동태 연구를 위한 혈청 중 펙소페나딘의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.437-443
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of a major metabolite of terfenadine, fexofenadine, in human serum was developed, validated, and applied to the pharmacokinetic study of terfenadine. Fexofenadine and internal standard, haloperidol were extracted from human serum by liquid-liquid extraction with acetonitrile and analyzed on a $Symmetry^{TM}$ C8 column with the mobile phase of 1% triethylamine phosphate (pH 3.7)-acetonitrile (67:33, v/v, adjusted to pH 5.6 with triethylamine). Detection wavelength of 230 nm for excitation, 280 nm for emission and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fexofenadine concentration (50 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 10 ng/mL, which was sensitive enough for the pharmacokinetic studies of terfenadine. The overall accuracy of the quality control samples ranged from 95.70 to 114.58% for fexofenadine with overall precision (% C.V.) being 3.53-14.39%. The relative mean recovery of fexofenadine for human serum was 90.17%. Stability studies (freeze-thaw, short-term, extracted serum sample and stock solution) showed that fexofenadine was stable during storage, or during the assay procedure in human serum. However, the storage at $-70^{\circ}C$ for 4 weeks showed that fexofenadine was not stable. The peak area and retention time of fexofenadine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fexofenadine in human serum samples for the pharmacokinetic studies of orally administered Tafedine tablet (60 mg as terfenadine) at three different laboratories, demonstrating the suitability of the method.

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

AKARI FAR-INFRARED ALL-SKY SURVEY MAPS

  • Doi, Yasuo;Komugi, Shinya;Kawada, Mitsunobu;Takita, Satoshi;Arimatsu, Ko;Ikeda, Norio;Kato, Daisuke;Kitamura, Yoshimi;Nakagawa, Takao;Ootsubo, Takafumi;Morishima, Takahiro;Hattori, Makoto;Tanaka, Masahiro;White, Glenn J.;Etxaluze, Mireya;Shibai, Hiroshi
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.111-116
    • /
    • 2012
  • Far-infrared observations provide crucial data for the investigation and characterisation of the properties of dusty material in the Interstellar Medium (ISM), since most of its energy is emitted between ~ 100 and $200{\mu}m$. We present the first all-sky image from a sensitive all-sky survey using the Japanese AKARI satellite, in the wavelength range $50-180{\mu}m$. Covering > 99% of the sky in four photometric bands with four filters centred at $65{\mu}m$, $90{\mu}m$, $140{\mu}m$, and $160{\mu}m$ wavelengths, this achieved spatial resolutions from 1 to 2 arcmin and a detection limit of < 10 MJy $sr^{-1}$, with absolute and relative photometric accuracies of < 20%. All-sky images of the Galactic dust continuum emission enable astronomers to map the large-scale distribution of the diffuse ISM cirrus, to study its thermal dust temperature, emissivity and column density, and to measure the interaction of the Galactic radiation field and embedded objects with the surrounding ISM. In addition to the point source population of stars, protostars, star-forming regions, and galaxies, the high Galactic latitude sky is shown to be covered with a diffuse filamentary-web of dusty emission that traces the potential sites of high latitude star formation. We show that the temperature of dust particles in thermal equilibrium with the ambient interstellar radiation field can be estimated by using $90{\mu}m$, $140{\mu}m$, and $160{\mu}m$ data. The FIR AKARI full-sky maps provide a rich new data set within which astronomers can investigate the distribution of interstellar matter throughout our Galaxy, and beyond.

Analysis of Trace Copper Metal at The Electrode Consisting of Carbon Nanotube using Stripping Voltammetry (벗김전압전류법을 이용한 카본나노튜브 전극에서의 구리 분석)

  • Choi, Chang-Kun;Jung, Young-Sam;Kim, Nack-Joo;Pak, Dae-Won;Chung, Kun-Yong;Kim, Lae-Hyun;Kwon, Yong-Chai
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.933-937
    • /
    • 2012
  • In the present study, we evaluate the sensitivity and optimal stripping voltammetry (SV) conditions of copper (Cu), which is one of the main trace heavy metals inducing the environmental contamination, using carbon nanotube (CNT) electrode. In addition, the reaction mechanism of stripping reaction of Cu is investigated. The electrochemical analyses such as squarewave stripping voltammetry (SWSV) and linear scan voltammetry (LSV) are used for the evaluations. As a result of that, the best SWSV conditions like squarewave amplitude of 15 mV, frequency of 60 Hz, deposition potential of -1.0V vs. Ag/AgCl and deposition time of 200s are determined with the measured Cu sensitivity of $1.824{\mu}A/{\mu}M$. As a driving force affecting the stripping reaction of Cu, surface reaction is more dominant one than diffusion. These results are compared with other reference results and it is confirmed that our suggested CNT electrode gives rise to better Cu sensitivity result than other references.