• Title/Summary/Keyword: Limit of Detection

Search Result 2,413, Processing Time 0.033 seconds

Optimization of Wave Forms for Pulsed Amperometric Detection of Cyanide and Sulfide with Silver-Working Electrode

  • Park, Seong U;Hong, Seong Uk;Yu, Jae Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.2
    • /
    • pp.143-146
    • /
    • 1996
  • A continuous potential pulse is applied to a silver-working electrode on a pulsed amperometric detector (PAD) for detection of free cyanide and sulfide. The moving phase is 0.1 M sodium hydroxide, 0.5 M sodium acetate and 5% (v/v) ethylenediamine mixture, and the flow rate is 0.7 mL/min. Optimized pulse conditions include a -200 mV (vs. Ag/AgCl reference electrode) detection potential(Ed) for 60 msec and 50 mV cleaning potential (Ec) for 120 msec. The silver working electrode surface is not poisoned by cyanide or sulfide, and the PAD maintains long-term stability without loss of sensitivity and reproducibility at these pulse conditions. The detection limit of cyanide and sulfide separated by ion chromatography using an anion exchange column is 0.1 ppm and 0.05 ppm, respectively.

Development and Application of Reverse Transcription Nanoplate-Based Digital PCR Assay for Sensitive and Accurate Detection of Rice Black-Streaked Dwarf Virus in Cereal Crops

  • Hyo-Jeong Lee;Hae-Jun Kim;Sang-Min Kim;Rae-Dong Jeong
    • The Plant Pathology Journal
    • /
    • v.40 no.4
    • /
    • pp.408-413
    • /
    • 2024
  • The emergence of rice black-streaked dwarf virus (RBSDV) poses a significant threat to global cereal crop cultivation, necessitating the urgent development of reliable detection and quantification techniques. This study introduces a reliable approach for the precise and sensitive quantification of the RBSDV in cereal crop samples, employing a reverse transcription digital polymerase chain reaction (RT-dPCR) assay. We assessed the specificity and sensitivity of the RT-dPCR assay proposed for precise RBSDV detection and quantification. Our findings demonstrate that RT-dPCR was specific for detection of RBSDV, with no cross-reactivity observed with other viruses infecting cereal crops. The RT-dPCR sensitivity was over 10 times that of RT-quantitative PCR (RT-qPCR). The detection limit of RT-dPCR was 0.096 copies/㎕. In addition, evaluation of RT-dPCR assay with field samples was conducted on 60 different cereal crop samples revealed that RT-dPCR (45/60) exhibited superior accuracy compared with RT-qPCR (23/60). In this study, we present a specific and accurate RT-dPCR assay for the detection and quantification of RBSDV.

Development and Characterization of Finger-type PIN Photodiode for Fluorescence Detection of RNA (RNA 형광 검출을 위한 Finger형 PIN 광다이오드의 제작 및 평가)

  • Kim, Ju-Hwan;Oh, Myung-Hwan;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2004
  • This paper represents the development of high sensitivity photo-sensor for the fluorescence detection in the integrated biological analysis system. The finger-type PIN photodiodes were fabricated as the photo-sensor, and had a high sensitivity ($I_{light}/I_{dark}$ = 8720). The interference filter consisted of $TiO_{2}$ and $SiO_{2}$ was directly deposited on the photodiodes. Deposited filter with 95.5% reflection under 532 nm and 98% transmission over 580 nm exceedingly decreased the magnitude of background signal in the detection. The PDMS micro-fluidic channels are bonded on the photodiode by $O_{2}$ plasma treatment. The detection current was proportional to two primary parameters (light intensity, concentration), and the on-chip detection system could detect fluorescence signals down to 100 nM concentration (LOD = Limit of detection of rhodamine).

Rapid and Sensitive Detection of Lettuce Necrotic Yellows Virus and Cucumber Mosaic Virus Infecting Lettuce (Lactuca sativa L.) by Reverse Transcription Loop-Mediated Isothermal Amplification

  • Zhang, Yubao;Xie, Zhongkui;Fletcher, John D;Wang, Yajun;Wang, Ruoyu;Guo, Zhihong;He, Yuhui
    • The Plant Pathology Journal
    • /
    • v.36 no.1
    • /
    • pp.76-86
    • /
    • 2020
  • Cucumber mosaic virus (CMV) is damaging to the growth and quality of lettuce crops in Lanzhou, China. Recently, however, for the first time an isolate of lettuce necrotic yellows virus (LNYV) has been detected in lettuce crops in China, and there is concern that this virus may also pose a threat to lettuce production in China. Consequently, there is a need to develop a rapid and efficient detection method to accurately identify LNYV and CMV infections and help limit their spread. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed to detect the nucleoprotein (N) and coat protein (CP) genes of LNYV and CMV, respectively. RT-LAMP amplification products were visually assessed in reaction tubes separately using green fluorescence and gel electrophoresis. The assays successfully detected both viruses in infected plants without cross reactivity recorded from either CMV or LNYV or four other related plant viruses. Optimum LAMP reactions were conducted in betaine-free media with 6 mM Mg2+ at 65℃ for LNYV and 60℃ for 60 min for CMV, respectively. The detection limit was 3.5 pg/ml and 20 fg/ml using RT-LAMP for LNYV and CMV plasmids, respectively. Detection sensitivity for both RT-LAMP assays was greater by a factor of 100 compared to the conventional reverse transcription polymerase chain reaction assays. This rapid, specific, and sensitive technique should be more widely applied due to its low cost and minimal equipment requirements.

Damage Classification by Time Density Function of Ultrasonic Pulse Signal occurred at Tire (타이어에서 발생하는 초음파펄스신호의 시간밀도함수에 의한 손상 분별)

  • Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.291-296
    • /
    • 2015
  • The tire damage classification method is researched on the periodicity detection of ramdomness ultrasonic signals to occur at the driving vehicle tire. Setting method of adaptive threshold is proposed in order to valid pulse detection by tire damage in ultrasonic noise on the road and used low pass filter for decrease signal ramdomness as preprocessing. Time interval of detected pulse is setted the density function depend on the vehicle's speed and the method of tire damage detection is proposed that measuring the first peak's time of time density function.The result of time density function in case of one damage material, the first peak's time is measured within the error limit of tire's rotation period, 169.8ms and 97.9ms and 81.8ms, about the speed of 50km/h and 80km/h and 100km/h. In case of more than one damage material, the sum of each peak's time is measured within the error limit of tire's rotation period about the speed.

Analytical Characteristics of GC/MS and HPLC according to the Concentration Distribution of PAHs (PAHs 농도 분포에 따른 GC/MS와 HPLC의 분석특성에 관한 연구)

  • Hong, Jwa-Ryung;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.312-321
    • /
    • 2015
  • Objectives: The purpose of this study was to determine the best method to analyze PAHs at extremely low concentrations. To this end, 16 PAHswere analyzed simultaneously by GC/MS, HPLC/FLD and HPLC/UVD, and the analytical characteristics of HPLC and GC/MS were compared. Methods: This study was conducted by GC/MS and HPLC/FLD/UVD, and evaluated linearity, precision and detection limit. Standard solutions were prepared for 21 samples in the range of $0.00001{\sim}1.0{\mu}g/mL$ and the samples were divided into four groups. All samples were made in three sets and analysis was replicated seven times. Results: Sixteen PAHs could be simultaneously separated by HPLC and GC/MS, and the adequate equipment was HPLC/FLD. The retention times by HPLC were shorter than GC/MS, and HPLC had better separation for most PAHs than GC/MS. The peaks of naphthalene and naphthalene-D8 partially overlapped for GC/MS. HPLC/FLD had a 20-2000 times lower limit of detection than GC/MS and UVD. However FLD was not adequate for analyzing acenaphthylene because it has too low a fluorescence quantum yield to be detected. The precision of HPLC/FLD/UVD and GC/MS showed less than 20% at $0.001{\mu}g/mL$ PAHs and when the concentration was higher, the coefficient of variation was decreased. HPLC/FLD was better for the overall detection of limits. Conclusions: The results indicate that the HPLC/FLD method has good linear range, precision and a detection of limits from $0.00001{\sim}0.0001{\mu}g/mL$ for all 16 PAHs. This study contributes to providing useful data for analysis technology and can be applied to occupational exposure measurement for PAHs in workplaces.

Determination of trace actinide (Am, Pu, Th, U) using alpha spectrometry and neutron activation analysis (알파분광법과 중성자방사화분석법에 의한 극미량의 악티늄계원소 (Am, Pu, Th, U)분석연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Kim, Yongjai;Lee, Myong Ho
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2004
  • Determination of actinides in the environmental sample requires separation of each element. This procedure is tedious and time consuming. And also, the detection limits of some nuclides using alpha spectrometry are rather higher. To overcome the lower detection limit and complicated separation procedure, a simple analytical technique for the determination of actinide isotopes in the environmental samples was developed and applied to IAEA and NIST reference sediment samples. For the separation of actinides from matrix, anion exchange resin and TRU-spec extraction chromatography resin were used and chemical yields were obtained using natural uranium, thorium, $^{242}Pu$ and $^{243}Am$ tracers. For overcoming the higher detection limits of U and Th in alpha spectrometry, neutron activation analysis was applied. Using combined method, the detection limit was increased about 10 times. The activity values of each isotope were consistent with the reference values reported by IAEA and NIST.

Liquid electrochemical sensors using carbon nanotube film (Carbon Nanotube Film을 이용한 액체 전기화학 센서)

  • Noh, Jaeha;An, Sangsu;Lee, Changhan;Lee, Sangtae;Lee, Moonjin;Seo, Dongmin;Chang, Jiho
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.255-260
    • /
    • 2021
  • We studied electrochemical sensors using printed carbon nanotube (CNT) film on a polyethylene terephthalate (PET) substrate. Multiwalled CNT films were printed on a PET substrate to study its feasibility as hazardous and noxious substances (HNS) detection sensor. The printed CNT film (PCF) with a 50 ㎛ thickness exhibited a specific resistance of 230 ohm. To determine the optimum sensor structure, a resistance-type PCF sensor (R-type PCF sensor) and a conductive-type PCF sensor (C-type PCF sensor) were fabricated and compared using diluted NH3 droplets with various concentrations. The response magnitude, response time, sensitivity, linearity, and limit of detection (LOD) were compared, and it was concluded that the C-type PCF sensor exhibited superior performance. By applying a C-Type PCF sensor, we confirmed the detection performance of 12 types of floating HNS and the response of the sensor with selectivity according to the degree of polarity.

Determination Method of Puerarin and Daidzin from Puerariae Radix by Reversed-Phase HPLC with Pulsed Amperometric Detection (RP-HPLC-PAD를 이용한 갈근(葛根)과 갈근(葛根) 함유 처방의 Puerarin과 Daidzin 분석)

  • Chiao, Chen-Ying;Kwon, Ha-Jeong;Jeong, Ji-Seon;Lee, Je-Hyun;Hong, Seon-Pyo
    • The Korea Journal of Herbology
    • /
    • v.23 no.4
    • /
    • pp.171-177
    • /
    • 2008
  • Objectives: This study presents a reversed-phase high-performance liquid chromatography- pulsed amperometric detection(RP-HPLC-PAD) method for the determination of puerarin and daidzin in Puerariae Radix extract and Chinese medicinal preparations. Methods: Chromatographic separation was performed using a 10% acetonitrile with a reversed-phase column(Unison UK-C18, $100mm{\times}2.0mm$ I.D.; $3{\mu}m$). The analyses were detected by pulsed amperometric detector(PAD) in alkaline conditions by combining with post-column NaOH solution. Geniposide was used as an internal standard. Results: The limit of detection(S/N=3) and the limit of quantification(S/N=10) were 0.025 ng, 0.075 ng for puerarin, and 0.05 ng, 0.15 ng for daidzin, respectively. The intra- and inter-day precisions(RSDs) were less than 6.5% and average recoveries of puerarin were 99.7-101.3% and those of daidzin were 101.0-102.8%. Conclusions: According to above results, we developed a determination method for puerarin and daidzin in Puerariae Radix with high sensitivity and selectivitely.

  • PDF

Machine Vision Platform for High-Precision Detection of Disease VOC Biomarkers Using Colorimetric MOF-Based Gas Sensor Array (비색 MOF 가스센서 어레이 기반 고정밀 질환 VOCs 바이오마커 검출을 위한 머신비전 플랫폼)

  • Junyeong Lee;Seungyun Oh;Dongmin Kim;Young Wung Kim;Jungseok Heo;Dae-Sik Lee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.112-116
    • /
    • 2024
  • Gas-sensor technology for volatile organic compounds (VOC) biomarker detection offers significant advantages for noninvasive diagnostics, including rapid response time and low operational costs, exhibiting promising potential for disease diagnosis. Colorimetric gas sensors, which enable intuitive analysis of gas concentrations through changes in color, present additional benefits for the development of personal diagnostic kits. However, the traditional method of visually monitoring these sensors can limit quantitative analysis and consistency in detection threshold evaluation, potentially affecting diagnostic accuracy. To address this, we developed a machine vision platform based on metal-organic framework (MOF) for colorimetric gas sensor arrays, designed to accurately detect disease-related VOC biomarkers. This platform integrates a CMOS camera module, gas chamber, and colorimetric MOF sensor jig to quantitatively assess color changes. A specialized machine vision algorithm accurately identifies the color-change Region of Interest (ROI) from the captured images and monitors the color trends. Performance evaluation was conducted through experiments using a platform with four types of low-concentration standard gases. A limit-of-detection (LoD) at 100 ppb level was observed. This approach significantly enhances the potential for non-invasive and accurate disease diagnosis by detecting low-concentration VOC biomarkers and offers a novel diagnostic tool.