• 제목/요약/키워드: Limit of Detection

검색결과 2,413건 처리시간 0.047초

Detection of Multi-class Pesticide Residues Using Surface Plasmon Resonance Based on Polyclonal Antibody

  • Yang, Gil-Mo;Kang, Suk-Won
    • Food Science and Biotechnology
    • /
    • 제17권3호
    • /
    • pp.547-552
    • /
    • 2008
  • The detection of carbamate (carbofuran, carbaryl, benfracarb, thiodicarb, and methomil) and organophosphate (diazinon, cadusafos, ethoprofos, parathion-methyl, and chlorpyrifos) pesticide residues with very low detection limits was carried out using surface plasmon resonance (SPR) based equipment. The capacity to develop a portable SPR biosensor for food safety was also investigated. The applied ligand for the immunoassays was polyclonal goat anti-rabbit immunoglobulin (IgG) peroxidase conjugate. Concentration tests using direct binding assays showed the possibility of quantitative analysis. For ligand fishing to find a proper antibody to respond to each pesticide, acetylcholinesterase (AChE), and glutathione-S-transferase (GST) were tested. The reproducibility and precision of SPR measurements were evaluated. With this approach, the limit of detection for pesticide residues was 1 ng/mL and analysis took less than 11 min. Thus, it was demonstrated that detecting multi-class pesticide residues using SPR and IgG antibodies provides enough sensitivity and speed for use in portable SPR biosensors.

배추에서 분리한 순무 모자이크 바이러스의 특성 및 역전사 중합효소 연쇄반응법(RT-PCR)을 이용한 검정 (Characterization and RT-PCR Detection of Turnip Mosaic Virus Isolated from Chinese Cabbage in Korea)

  • 박원목;최설란;김수중;최승국;류기현
    • 한국식물병리학회지
    • /
    • 제14권3호
    • /
    • pp.223-228
    • /
    • 1998
  • Turnip mosaic virus)TuMV-Ca) was isolated from a Chinese cabbage showing severe mosaic and black necrotic spots symptoms in Korea. The virus was identified as a strain of TuMV by its host range test, particle morphology, serology, double stranded RNA analysis. For detection of the virus, reverse transcription and polymerase chain reaction(RT-PCR) was performed with a set of 18-mer TuMV-specific primers to amplify a 876 bp DNA fragment The virus was rapidly detected from total nucleic acids of virus infected tissues as well as native viral RNA of purified virion particles by RT-PCR. Detection limit of the viral RNA by RT-PCR was 10 fg.

  • PDF

Simple Ratiometric Fluorophore for the Selective Detection of Mercury through Hg(II)-Mediated Oxazole Formation

  • Lee, Hee-Jin;Kim, Hae-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권11호
    • /
    • pp.3959-3962
    • /
    • 2011
  • A simple propargylamide-fuctionalized chemodosimeter was prepared for the ratiometric fluorescence detection of mercuric ions in HEPES buffer. The chemodosimeter exhibited $Hg^{2+}$-induced propargyl amide-tooxazole transformation, with a significant accompanying ratiometric change in fluorescence. It afforded high selectivity for mercuric ion detection without any competitive inhibition by common alkali, alkaline earth, or other transition metal ions. The probe showed a $17{\times}10^{-6}M$ detection limit for $Hg^{2+}$ ions and potential applicability for detecting aqueous $Hg^{2+}$ ions.

Loop-mediated isothermal amplification assay for the detection of Salmonella spp. in pig feces

  • Kim, Yong Kwan;Kim, Ha-Young;Jeon, Albert Byungyun;Lee, Myoung-Heon;Bae, You-Chan;Byun, Jae-Won
    • 대한수의학회지
    • /
    • 제54권2호
    • /
    • pp.113-115
    • /
    • 2014
  • Salmonella are causative agents of gastroenteritis and systemic disease in animals. The invA gene was selected as a target sequence of loop-mediated isothermal amplification (LAMP) assay for diagnosis of Salmonella infection. The detection limits for broth dilution, spiked feces and enrichment were $10^4$, $10^5$ and $10^2$ CFUs/mL, respectively. The LAMP assay developed in the present study may be a reliable method for detection of Salmonella spp. in pig feces.

브레이크다운전압 특성을 이용한 엔진실화의 검출 및 강도해석 (The Misfire Detection and Intensity Interpretation using Breakdown Voltage Characteristics)

  • 고용수;박재근;조민석;황재원;채재우
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.42-48
    • /
    • 1999
  • Engine misfire causes of the negative effect on exhaust emission such as HC, CO, and NOX . Moreover, it causes damage to the three-way-catalyst(TWC) system permanently. The crankshaft velocity fluctuation(CVF) method has been applied for the real cars as misfire detection system usually, which utilizes the crank angle sensor input to calculate the variation of the crankshaft rotational speed. But this approach has the limit due to the fact that three could be problem under certain engine condition like as deceleration or high speed condition . Therefore the development of new methods are requested today. This study introduced the new method of misfire detection using breakdown voltage(BDV) characteristics between spark plug electrouds.

  • PDF

레이저 애벌레이션 분광을 이용한 고분자 표면의 나노미터 스케일 표면 분석 (Nanometer-Scale Surface Analysis of Polymers Using Laser Ablation Spectroscopy)

  • 김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1334-1336
    • /
    • 2001
  • In this study, laser ablation atomic fluorescence (LAAF) spectroscopy has been applied for a nanometer-scale surface analysis of Na-doped polymethyl methacrylate (PMMA). LAAF spectroscopy is a new sensitive element detection technique which involves atomizing of a sample by the laser ablation and detection of ablated plume by laser-induced fluorescence (LIF) spectroscopy. Using this technique in the detection of Na atoms with Na-doped PMMA, a detection limit is obtained as 36 fg for single laser shot. Further, the depth distribution in the sample is measured with a very high spatial resolution using a two-layer PMMA sample by observing the shot-by-shot LIF intensity from the Na atoms.

  • PDF

ELISA에 의한 T-2 toxin의 분석법에 관한 연구 (Studies on Analysis Method of T-2 Toxin by ELISA)

  • 오유진;장성재;윤여표
    • 한국식품위생안전성학회지
    • /
    • 제3권2호
    • /
    • pp.65-73
    • /
    • 1988
  • 종래의 화학적, 생물학적 분석방법의 단점인 검출한도가 낮은점, 시료전처리의 복잡성, 비경제성 및 비 특이성 등을 극복하기 위해 monoclonal AB를 사용한 ELISA법으로 T-2 toxin 에 대해 특이성있는 새로운 분석법을 개발하여 다음과 같은 결과를 얻었다. 1. 종래의 GLC 및 GC-MS 분석법보다 간편하고 신뢰성이 높으며 검출한계가 0.1ppb인 고감도의 분석법을 개발하였다. 2. 본 분석법을 이용하여 Fusarium spp. 균의 T-2 생산유무를 단시간에 다량의 시료를 검색할 수 있었으며, data의 정확도가 GLC와 유사하며 GLC로는 검색할 수 없는 150ppb이하의 미량함유 시료에서도 T-2 toxin을 검색할 수 있었다. 3. 본 실험에 사용한 F. sporotichioides M-1-1 균주의 밀에 대한 최적 배양조건은 $24~27^{\circ}C$ 2주간임을 알았다.

  • PDF

기하학적 기법을 이용한 하이퍼스펙트럴 영상의 Linear Spectral Mixing모델에 관한 연구 (A Study on Linear Spectral Mixing Model for Hyperspectral Imagery with Geometric Method)

  • 장은석;김대성;김용일
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2003년도 추계학술대회논문집
    • /
    • pp.23-29
    • /
    • 2003
  • Detection in remotely sensed images can be conducted spatially, spectrally or both [2]. If the images have high spatial resolution, materials can be detected by using spatial and spectral information, unless we can't see the object embedded in a pixel. In this paper, we intend to solve the limit of spatial resolution by using the hyperspectral image which has high spectral resolution. Therefore, the Linear Spectral Mixing(LSM) Model which is sub-pixel detection algorithm is used to solve this problem. To find class Endmembers, we applied Geometric Model with MNF(Minimum Noise Fraction) transformation. From the result of sub-pixel detection algorithm, we can see the detection of water is satisfied and the object shape cannot be extracted but the possibility of material existence can be identified.

  • PDF

Disposable in-field electrochemical potable sensor system for free available chlorine (FAC) detection

  • Chang, Seung-Cheol;Park, Deog-Su
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.449-456
    • /
    • 2007
  • The work described in this study concerns the development of a disposable amperometric sensor for the electrochemical detection of a well-known aqueous pollutant, free available chlorine (FAC). The FAC sensor developed used screen printed carbon electrodes (SPCEs) coupled with immobilised syringaldazine, commonly used as an indicator in photometric FAC detection, which was directly immobilised on the surface of SPCEs using a photopolymer PVA-SbQ. To enable in-field analysis of FAC, a prototype hand-held electrochemical analyzer has been developed to withstand the environment with its rugged design and environmentally sealed connections; it operates from two PP3 (9 volt) batteries and is comparable in accuracy and sensitivity to commercial bench top systems. The sensitivity of the FAC sensor developed was $3.5{\;}nA{\mu}M^{-1}cm^{-2}$ and the detection limit for FAC was found to be $2.0{\;}{\mu}M$.

Alizarin Red S modified electrochemical sensors for the detection of aluminum ion

  • Chang, Seung-Cheol
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.421-427
    • /
    • 2010
  • Alizarin Red S modified screen printed carbon electrodes were developed for the electrochemical detection of aluminum ion. The electrodes developed use screen-printed carbon electrodes(SPCEs) coupled with chemical modification with an organic chelator, Alizarin Red S(ARS), for aluminum ion detection in aqueous solution. For sensor fabrication ARS was directly immobilized on the surface of SPCEs using PVA-SbQ(The poly(vinyl alcohol) bearing stryrylpyridinium groups). Aluminum concentrations were indirectly estimated by amperometric determination of the non-complexed ARS immobilized on the electrodes, after its complexation with aluminum. The sensitivity of the sensor developed was $3.8\;nA{\mu}M^{-1}cm^{-2}$ and the detection limit for aluminum was $25\;{\mu}M$.