• Title/Summary/Keyword: Limit Error

Search Result 557, Processing Time 0.026 seconds

The NAND Type Flash EEPROM Using the Scaled SONOSFET (Scaled SONOSFET를 이용한 NAND형 Flash EEPROM)

  • 김주연;권준오;김병철;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.145-150
    • /
    • 1998
  • 8$\times$8 bit scaled SONOSFET NAND type flash EEPROM that shows better characteristics on cell density and endurance than NOR type have been designed and its electrical characteristics are verified with computer aided simulation. For the simulation, the spice model parameter was extracted from the sealed down SONOSFET that was fabricated by $1.5mutextrm{m}$ topological design rule. To improve the endurance of the device, the EEPROM design to have modified Fowler-Nordheim tunneling through the whole channel area in Write/Erase operation. As a result, it operates Write/Erase operation at low current, and has been proven Its good endurance. The NAND type flash EEPROM, which has upper limit of V$_{th}$, has the upper limit of V$_{th}$ as 4.5V. It is better than that of floating gate as 4V. And a EEPROM using the SONOSFET without scaling (65$\AA$-l65$\AA$-35$\AA$), was also designed and its characteristics have been compared. It has more possibliity of error from the V$_{th}$ upper limit as 4V, and takes more time for Read operation due to low current. As a consequence, it is proven that scaled down SONOSFET is more pertinent than existing floating gate or SONOSFET without scaling for the NAND type flash EEPROM.EPROM.

  • PDF

The Accuracy of Prescriptions Using a Computerized Chemotherapy Order System (항암화학요법 처방전산 시스템에 의한 처방 정확도에 관한 연구)

  • Kim, Jung-Tae;Lee, Jae-Hwan;Shin, Hyun-Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • A computerized chemotherapy order system (CCOS) was developed to improve the accuracy and efficiency of prescriptions for pharmacy medication scheduling at a teaching hospital, Asan Medical Center, Seoul, Korea. We evaluated the system by comparing prescriptions before and after the implementation of the system and by analyzing the effects of the system on dosing accuracy (only against 5-FU), prescription change, overdoses above maximum limit and medication disposal in non computerized program group (control group) and CCOS group. In terms of dosing accuracy, prescription error rate (%) was significantly decreased in CCOS groups compared with the control group. The rate of prescription changes was also significantly decreased in CCOS groups. Regarding overdoses above maximum limit, we found that there was no prescription order exceeding the dosage limit in CCOS groups in contrast to significant overdoses in control group. In terms of medication disposal, there was no significant difference between 2 groups. We suggest that the computerized chemotherapy order system for chemotherapy may bean important and useful tool for minimizing prescribing errors in the hospitals.

  • PDF

Parallel Generation of NC Tool Paths for Subdivision Surfaces

  • Dai Junfu;Wang Huawei;Qin Kaihuai
    • International Journal of CAD/CAM
    • /
    • v.4 no.1
    • /
    • pp.47-53
    • /
    • 2004
  • The subdivision surface is the limit of recursively refined polyhedral mesh. It is quite intuitive that the multi-resolution feature can be utilized to simplify generation of NC (Numerical Control) tool paths for rough machining. In this paper, a new method of parallel NC tool path generation for subdivision surfaces is presented. The basic idea of the method includes two steps: first, extending G-Buffer to a strip buffer (called S-Buffer) by dividing the working area into strips to generate NC tool paths for objects of large size; second, generating NC tool paths by parallel implementation of S-Buffer based on MPI (Message Passing Interface). Moreover, the recursion depth of the surface can be estimated for a user-specified error tolerance, so we substitute the polyhedral mesh for the limit surface during rough machining. Furthermore, we exploit the locality of S-Buffer and develop a dynamic division and load-balanced strategy to effectively parallelize S-Buffer.

A Study on Response Surface Method Using the Vector Projection Technique (벡터투영법을 이용한 응답면기법에 관한 연구)

  • 김상효;나성원;김우곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.167-174
    • /
    • 1994
  • In this study, an improved response surface method is proposed. By using gradient projection method, the sampling points for creating response surface are evaluated at the region close to the failure surface. This points are combined with linear response surface function and Rackwitz-Fiessler algorithm. Also, a method controlling the range of selecting sampling points considering the non-linearity of the limit states is proposed to reduce the error produced by approximating the non-linear limit state to linear response surface. With the examples the result of the proposed method is found to be more accurate and efficient than the previous response surface method.

  • PDF

A Study on Numerical Perforation Analysis of Axisymmetric Bullet by the Particle Method (입자법을 이용한 축대칭 탄자의 관통거동 수치해석 연구)

  • Kim, Yong-Seok;Kim, Yong-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.164-171
    • /
    • 2008
  • A modified generalized particle algorithm, MGPA, was suggested to improve the computational efficiency of standard SPH method in numerical analysis of high speed impact behavior. This method uses a numerical failure mechanism than material failure models to describe the target penetration. MGPA algorithm was more effective to describe the impact phenomena and new boundaries produced during the calculation process were well recognized and treated in the target penetration problem of a bullet. When bullet perforation problems were analyzed by this method, MGPA algorithm calculation gives the stable numerical solution and stress oscillation or particle penetration phenomena were not shown. The error range in ballistic velocity limit is less than $2{\sim}13%$ for various target thickness.

A study on the robot controller design using a reduced-order observer (축소차수 관측기를 이용한 로보트 제어기 설계에 관한 연구)

  • 김도식;김진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1-6
    • /
    • 1991
  • This paper is concerned with the design of a robust tracking controller using a state observer on a robotic manipulator under the disturbance. The controller is designed to follow a step or ramp reference input without steady state error in the presence of a disturbance and a system parameter variation. In most cases, since all the state vectors are not measured, unmeasurable state vectors must be estimated or reconstructed. A reduced order observer is proposed to estimate unmeasurable state vectors of the non-linear system. Some problems are caused by the Coulomb friction, the disturbance, and the spring effect of a link between the drive motor and the manipulator arm. The state variables, directly measured and estimated by the reduced order observer, are fed back to the controller. When the robot system exhibits the 'limit cycle, the feedback gains initially obtained by optimal control theory are changed. As a result, the limit cycle is eliminated by the new controller gains,

  • PDF

Position servo control of a PR type pneumatic manipulator (PR형 공압 머니퓰레이터의 위치서보제어)

  • Lim, Seung-Cheol;Eao, Yun-Beom
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1619-1625
    • /
    • 1997
  • This paper concerns a 2-axis PR type pneumatic manipulator system translating in vertical and rotating in horizontal directions. A simplified linear model is mathematically formulated similar to the pneumatic acturators in dynamic responses in order to devise an appropriate position control scheme. A PD controller preceding the on/off solenoid valve turns out not only economical but also effective in reducing rise time and amplitude of limit cycles, if its control gains are determined on the basis of frequency response. And, additional implementation of symmetric or asymmetric deadband at the PD controller output greatly helps minimize valve opening numbers, positional error, and undesirable direction-dependent property due to the gravitational load. Such a control concept is synthesized through numerical simulations and next applied to the experimental set-up, featuring enhanced positional servo characteristics.

Numerical Simulation of Tensile Strength Test by Ring-type Specimen (링 시험편에 의한 인장강도시험의 수치해석)

  • 진연호;양형식;박철환
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.63-66
    • /
    • 2000
  • Stress variation due to size variation and the eccentricity of ring type tensile specimen was analyzed by FLAC program. To get the stable tensile strength the ratio of inner to outer ring diameter should be within a certain range. Diameter ratio of 0.3 was suggested to be adequate. It seemed to be difficult to determine the tensile strength because of stress distortion if eccentricity exceeded home limit. To limit the error in 10%, lateral and axial eccentricity was analyzed to be in the limits of 3% and 10%, respectively.

  • PDF

Numerical Simulation of Tensile Strength Test by Ring-type Specimen (링 시험편에 의한 인장강도시험의 수치해석)

  • 진연호;양형식;박철환
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.316-319
    • /
    • 2000
  • Stress variation due to size variation and the eccentricity of ring type tensile specimen was analyzed by FLAC program. To get the stable tensile strength the ratio of inner to outer ring diameter should be within a certain range. Diameter ratio of 0.3 was suggested to be adequate. It seemed to be difficult to determine the tensile strength because of stress distortion if eccentricity exceeded some limit. To limit the error in 10%, lateral and axial eccentricity was analyzed to be in the limits of 3% and 10%, respectively.

  • PDF

Some Improvements of Gamma-ray Measurement for the Determination of the Boron Content (붕소 함량결정을 위한 즉발 감마선 계측법의 개선)

  • Nak Bae Kim;Hae-Ill Bak
    • Nuclear Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.18-20
    • /
    • 1984
  • The detection limit of boron has been lowered further in the capture gamma-ray measurement after preconcentration of boron by placing natural lithium brick in front of Ge(Li) detector. The experimental detection limit is found to be 0.30ppm, 0.18ppm, 0.045ppm and 0.090ppm for the samples of aluminum, steel, uranium dioxide and graphite, respectively. An alternate counting technique kas been also used for neglecting the error caused by the fluctuation of neutron flux during counting.

  • PDF