• Title/Summary/Keyword: Limestone Slurry pH

Search Result 7, Processing Time 0.022 seconds

Improvement of Desulfurization Performance of Low-grade Limestone Slurry Using Organic Acid Additives (유기산 첨가제를 이용한 저품질 석회석 슬러리의 탈황 성능 개선)

  • Jeong, Ji Eun;Cho, In Ah;Lee, Chang-Yong
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.190-196
    • /
    • 2021
  • Desulfurization reaction in a bubble type reactor was carried out by adding three organic acids such as acetic acid, lactic acid, and antic acid to investigate the enhancement of the desulfurization performance of low-grade limestone. Desulfurization of limestone slurry without organic acids initiated to degrade at pH 5.2 or less, whereas organic acid-added limestone slurry exhibited a stable efficiency in the initial desulfurization with slurry pH ranging 4.2~4.5. At slurry pH below 4, the desulfurization performance of limestone slurry with addition of organic acids may be related to the amount of anions produced by dissociation of the organic acids. When limestone slurry had a large amount of anions, a rapid decrease in buffer capacity of slurry pH did not occur. These results were due to the acidity and dissociation of organic acids. The desulfurization performance of low-grade limestone slurry increased in the order of acetic acid (2.6%) < lactic acid (6.4%) < formic acid (16.7%).

Desirable pH of Slurry in the Desulfurization Absorber for a 200 MW Anthracite Power Plant (200 MW급 무연탄 발전용 탈황 흡수탑에서 적정 슬러리pH)

  • Choi, Hyun-Ho;Yoo, Hoseon
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.38-43
    • /
    • 2020
  • In this study, Seochon Thermal Power Plant No.1 for anthracite coal was tested to find the proper operation range of limestone slurry pH in the absorber tower which can be operated continuously in compliance with the Air Quality Preservation Act and Seocheon Thermal Power Division's internal regulation, sulfur dioxide average emission regulation. When operating the sulfur dioxide concentration [ppm] in the combustion gas flowing into the desulfurization absorption tower at 370, 400, 460 and 550 ppm while the main operating elements such as the flow rate of the combustion gas were fixed, the proper slurry pH Were 4.4, 4.5, 4.8 and 5.1, respectively. Therefore, it is recommended to operate with the correlation equation, RpH=0.004×Cin+2.93 derived using sulfur dioxide and the appropriate slurry pH.

Effect of Limestone Particle Size on the performance of FGD system (석회석 입도에 따른 습식배연탈황 성능연구)

  • Lee, Kyeong-Woo;Hwang, Jae Dong;Woo, Kwangje;Jang, Gil Hong
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.81-88
    • /
    • 2001
  • Limestone has been used as absorbent in the FGD(Flue Gas Desulfurization) system, the DeSOx system of thermal power plant. This study investigated the desulfurization characteristics of the two different limestones, 325mesh and 200mesh particle size. Experimental analysis showed that the dissolving rate of limestone became much slower as the particle size increased. But the desulfurization efficiency depended on the L/G(liquid/gas) ratio and slurry pH regardless of the limestone particle size. The quality of gypsum produced in the FGD process increased as the limestone particle size or the slurry pH decreased. To reduce the cost of absorbent, the mixed limestone which were composed of 200 and 325mesh limestone with 5 different ratios were tested.

  • PDF

Evaluation of SO2 Absorption Efficiency for Calcined Oyster Shell Slurry Using a Simulated Spray Type-flue Gas Desulfurization (FGD) System: A Comparative Study with Limestone Slurry (모사 Spray Type 배연탈황설비를 이용한 소성패각 슬러리의 SO2 흡수능 평가: 석회석과의 비교연구)

  • Kim, Seok-Hwi;Hong, Bum-Uh;Lee, Jin-Won;Cha, Wang-Seok;Kim, Kangjoo;Moon, Bo-Kyung
    • Economic and Environmental Geology
    • /
    • v.52 no.2
    • /
    • pp.119-128
    • /
    • 2019
  • About 300,000 tones of oyster shell are annually produced in Korea and, thus, a massive recycling plan is required. Many desulfurizing studies using oyster shells with chemical composition of $CaCO_3$ have been performed so far; however, most of them have focused on dry desulfurization. This study investigates the possibility of using oyster shells for wet desulfurization after calcination. For this, a simulated wet desulfurization facility of spray type was devised and compared the SOx-stripping characteristics of calcined oyster shell with those of limestone. The calcined oyster shell slurry indicate a better desulfurizability than the slurries of raw shell or limestone because the oyster shell transformed to a more reactive phase ($Ca(OH)_2$) by the calcination and hydration. Because of this reason, when the calcined oyster shell slurries were used, the reaction residue showed the higher gypsum ($CaSO_4{\cdot}2H_2O$) contents than any other cases. In the continuous desulfurization experiments, calcined oyster shell slurry showed a wider pH variation than limestone or raw oyster shell slurries, another clear indication of high reactivity of calcined oyster shells for $SO_2$ absorption. Our study also shows that the efficiency of wet desulfurization can be improved by the use of calcined oyster shells.

Desirable pH of Slurry in Desulfurization Absorber for a 1000 MW Coal Fired Power Plant (1000 MW급 석탄화력발전용 탈황흡수탑의 적정슬러리 pH)

  • Park, Jeong-kee;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.1
    • /
    • pp.38-44
    • /
    • 2019
  • This research is an experimental investigation to find the desirable pH of slurry in the desulfurization absorber for a 1000 ㎿ coal fired power plant, operating in compliance with the Air Environmental Conservation Act and the plant's internal regulations. In case the average sulfur dioxide concentration in inflow flue gas, ${\bar{C\;in}}$ [ppm] changed to 500 ppm, 550 ppm, 600 ppm and 635 ppm after fixing inflow flue gas flow rate, generator output, pressure drop in the absorber, and oxidation air flow rate, the desirable pH of the slurry in the absorber, was 5.0, 5.2, 5.3 and 5.4. Thus, it is recommended that the desirable pH of slurry is calculated using the correlation equation, $RpH=0.0018{\times}{\bar{C\;in}}+4,2031$ when the average sulfur dioxide concentration in the inflow flue gas is in the range of 500 ppm to 635 ppm.

Removal of Fluoride Ions from Electronic Industrial Wastewater Using Lime Stone Slurry (초미분말 석회석 현탁액을 이용한 전자산업 폐수 불소이온 제거연구)

  • Park, Hyeon Soo;Park, Yeon Soo;Jung, Goo Ill;Kim, Jae Woo;Jo, Young Min
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.258-263
    • /
    • 2018
  • This study attempted to utilize ultrafine precipitated calcium carbonate for fluoride removal from the wastewater of electronics industries. An average particle size of the calcium carbonate was $0.96{\mu}m$, and pH of the aqueous slurry was 10 with 70% in mass. The suspension solution showed approximately 2 mL/hr of the sedimentation rate. The present calcium carbonate solution could be comparable to the conventional aqueous calcium source, $Ca(OH)_2$, for the neutralization and removal of fluoride ions. Depending on the amount of an additional alkali source, less amounts of test Ca-source slurries were required to reach the solution pH of 7.0 than that of using the aqueous calcium hydroxide. It was also found from XRD analysis that more calcium fluoride precipitates were formed by the addition of calcium carbonate solution rather than that of calcium hydroxide. In addition, Minteq equilibrium modelling estimated various ion complexes of fluoride and calcium in this process.

Treatment of Abandoned Coal Mine Discharged Waters Using Lime Wastes

  • Park Joon-Hong;Kim Hee-Joung;Yang Jae-E.;Ok Yong-Sik;Lee Jai-Young;Jun Sang-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.10a
    • /
    • pp.59-61
    • /
    • 2005
  • In Korea, hundreds of abandoned and closed coal and metallic mines are present in the steep mountain valleys due to the depression of the mining industry since the late 1980s. From these mines, enormous amounts of coal waste were dumped on the slopes, which causes sedimentation and acid mine drainage (AMD) to be discharged directly into streams causing detrimental effects on soil and water environments. A limestone slurry by-product (lime cake) is produced from the Solvay process in manufacturing soda ash. It has very fine particles, low hydraulic conductivities ($10^{-8}{\sim}10^{-9}cm/sec$), high pH, high EC due to the presence of CaO, MgO and $CaCl_2$ as major components, and traces of heavy metals. Due to these properties, it has potential to be used as a neutralizer for acid-producing materials. A field plot experiment was used to test the application of lime cake for reclaiming coal wastes. Each plot was 20 x 5 m (L x W) in size on a 56% slope. Treatments included a control (waste only), calcite ($CaCO_3$), and lime cake. The lime requirement (LR) for the coal waste to pH 7.0 was determined and treatments consisted of adding 100%, 50%, and 25% of the LR. The lime cake and calcite were also applied in either a layer between the coal waste and topsoil or mixed into the topsoil and coal waste. Each plot was hydroseeded with grasses and planted with trees. In each plot, surface runoff and subsurface water were collected. The lime cake treatments increased the pH of coal waste from 3.5 to 6, and neutralized the pH of the runoff and leachate of the coal waste from 4.3 to 6.7.

  • PDF