Numerical Study on the Erosion Tendency of Centrifugal Slurry Pump Impeller for Thermal Power Plants (화력발전소용 원심 슬러리 펌프 임펠러의 침식경향 해석적 연구)

  • Cheon, Min-Woo;Lee, Chul-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.101-108
    • /
    • 2022
  • Centrifugal pumps are typically used in many slurry industries to transport solid materials. Solid particles in the slurry frequently shock the walls inside the pump, significantly abrading the flow path. Wear damage causes replacement of the pump components, which wastes manpower and time. Therefore, previous studies have been conducted on factors to improve efficiency and life time. This study identifies trends in pumps supplying lime to desulfurized devices from thermal power plants. The shear stress transport(SST) model is used to determine the erosion trend of the centrifugal pump that transfers lime slurry. The purpose of this study is to identify efficiency and erosion trends by selecting three of the various impeller design elements. The three impeller blade design variables mentioned above represent the inlet draft angle and blade angle of leading edge(L.E) and trailing edge(T.E). The maximum value of the erosion density rate tends to be similar to the Input power.

Improvement of bearing capacity of footing on soft clay grouted with lime-silica fume mix

  • Fattah, Mohammed Y.;Al-Saidi, A'amal A.;Jaber, Maher M.
    • Geomechanics and Engineering
    • /
    • v.8 no.1
    • /
    • pp.113-132
    • /
    • 2015
  • In this study, lime (L), silica fume (SF), and lime-silica fume (L-SF) mix have been used for stabilizing and considering their effects on the soft clay soil. The improvement technique adopted in this study includes improving the behaviour, of a square footing over soft clay through grouting the clay with a slurry of lime-silica fume before and after installation of the footing. A grey-colored densified silica fume is used. Three percentages are used for lime (2%, 4% and 6%) and three percentages are used for silica fume (2.5%, 5%, 10%) and the optimum percentage of silica fume is mixed with the percentages of lime. Several tests are made to investigate the soil behaviour after adding the limeand silica fume. For grouting the soft clay underneath and around the footing, a 60 ml needle was used as a liquid tank of the lime-silica fume mix. Slurried silica fume typically contains 40 to 60% silica fume by mass. Four categories were studied to stabilize soft clay before and after footing construction and for each category, the effectiveness of grouting was investigated; the effect of injection hole spacing and depth of grout was investigated too. It was found that when the soft clay underneath or around a footing is injected by a slurry of lime-silica fume, an increase in the bearing capacity in the range of (6.58-88)% is obtained. The footing bearing capacity increases with increase of depth of grouting holes around the footing area due to increase in L-SF grout. The grouting near the footing to a distance of 0.5 B is more effective than grouting at a distance of 1.0 B due to shape of shear failure of soft clay around the footing.

Fluoride Wastewater Treatment using Waste Concrete Powder (폐콘크리트분말을 이용한 불산폐수 처리)

  • Kim, Eun-I;Kang, Wan-Hyup;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.125-134
    • /
    • 2005
  • Waste concrete powder was used to remove fluoride ions in highly concentrated fluoride wastewater. 92.6% of fluoride in 100 mg F/L wastewater was removed by 1% dose of the cement paste powder that represents characteristics of waste concrete powder, whereas the removal efficiencies of raw cement and lime were 47.3% and 96.4%, respectively. The cement paste powder was competitive to lime, common fluoride removal agent. Various Ca-bearing hydrates such as portlandite, calcium silicate hydrate, and ettringite in cement paste slurry can remove fluoride by precipitating $CaF_2$ and absorbing $F^-$ ions. In the experiments using both cement paste and lime, 50~67% of lime can be substituted by cement paste to satisfy fluoride effluent limitation of 15 mg/L. Since cement paste has higher acid neutralization capacity than lime, it can be recycled to neutralize more acid and to remove more fluoride. Therefore waste concrete powder can be more economical and viable alternative for lime in fluoride wastewater treatment.

A Study on the Mix Design and Quality Factors of the Combined High Flowing Concrete Using High Belite Cement

  • Kwon, Yeong-Ho
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.121-129
    • /
    • 2002
  • This study investigates experimentally into the design factors and quality variations having an effect on the properties of the combined high flowing concrete to be poured in the slurry wall of Inchon LNG in-ground receiving terminal. Especially, high belite cement and lime stone powder as cementitious materials and viscosity agent in order to improve self-compaction and hydration heat are used in this study. Water-cement ratio(W/C), fine aggregate volume ratio(Sr) and coarse aggregate volume ratio(Gv) as design factors of the combined high flowing concrete are applied to determine the optimum mix design proportion. Also quality variations for sensitivity test are selected items as followings. (1)Surface moisture(5cases) and (2)Fineness modulus of fine aggregate(5cases), (3)Concrete temperature(3cases), (4)Specific surface(3cases) and particle size of lime stone powder. As experimental results, water-cement ratio, fine and coarse aggregate volume ratio are shown as the optimum range 51%, 43% and 53% separately considering site condition of slurry wall. Also quality factors by sensitivity test should be controlled in the following ranges. (1) Surface moisture :to.67% and (2)Fineness modulus 2.6$\pm$0.2 of fine aggregate, (3)Concrete temperature l0-20t, (4) Specific surface 6,000$\textrm{cm}^2$/g and particle size 9.7$\pm$1.0${\mu}{\textrm}{m}$ of lime stone powder. Based on the results of this study, the optimum mix design proportion of the combined high flowing concrete are selected and poured successfully in the slurry wall of LNG in-ground tank.

  • PDF

A Study on optical glass polishing using Fixed Abrasive Pad (고정입자패드를 이용한 광학 유리 폴리싱에 관한 연구)

  • 최재영;김초윤;박재홍;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.78-81
    • /
    • 2003
  • Polishing Processes are widely used in the glass, optical, die and semiconductor industry and are conventionally carried out using abrasive slurry and a polishing pad. But abrasive slurry process has a weak point that is high cost of handling of used slurry and hard controllability of slurry. Recently, some researches have attempted to solve these problems and one method is the development of a fixed abrasive pad. FAP has a couple of advantages including clean environment, lower CoC, easy controllability and higher form accuracy. But FAP also has a weak point that is need of dressing because of glazing and loading. The paper introduces the basic concept and fabrication technique of FAP using hydrophilic polymers with swelling characteristics in water and explains the self-conditioning phenomenon. Experimental results demonstrate to achieve nano surface roughness of soda lime glass for optical application

  • PDF

Treatment of Abandoned Coal Mine Discharged Waters Using Lime Wastes

  • Park Joon-Hong;Kim Hee-Joung;Yang Jae-E.;Ok Yong-Sik;Lee Jai-Young;Jun Sang-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.10a
    • /
    • pp.59-61
    • /
    • 2005
  • In Korea, hundreds of abandoned and closed coal and metallic mines are present in the steep mountain valleys due to the depression of the mining industry since the late 1980s. From these mines, enormous amounts of coal waste were dumped on the slopes, which causes sedimentation and acid mine drainage (AMD) to be discharged directly into streams causing detrimental effects on soil and water environments. A limestone slurry by-product (lime cake) is produced from the Solvay process in manufacturing soda ash. It has very fine particles, low hydraulic conductivities ($10^{-8}{\sim}10^{-9}cm/sec$), high pH, high EC due to the presence of CaO, MgO and $CaCl_2$ as major components, and traces of heavy metals. Due to these properties, it has potential to be used as a neutralizer for acid-producing materials. A field plot experiment was used to test the application of lime cake for reclaiming coal wastes. Each plot was 20 x 5 m (L x W) in size on a 56% slope. Treatments included a control (waste only), calcite ($CaCO_3$), and lime cake. The lime requirement (LR) for the coal waste to pH 7.0 was determined and treatments consisted of adding 100%, 50%, and 25% of the LR. The lime cake and calcite were also applied in either a layer between the coal waste and topsoil or mixed into the topsoil and coal waste. Each plot was hydroseeded with grasses and planted with trees. In each plot, surface runoff and subsurface water were collected. The lime cake treatments increased the pH of coal waste from 3.5 to 6, and neutralized the pH of the runoff and leachate of the coal waste from 4.3 to 6.7.

  • PDF

Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor (실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구)

  • 동종인;구우회;임대현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

A Study on the Coagulation of Wastewater Containing Fine Silica Particles with the Waste Slurry from Soda Ash Manufacturing Industries (소오다회 제조 공장의 폐슬러리를 이용한 미세 실리카 함유 폐수의 응집에 관한 연구)

  • Jun, Se Jin;Yim, Sung Sam
    • Applied Chemistry for Engineering
    • /
    • v.10 no.7
    • /
    • pp.1073-1078
    • /
    • 1999
  • The objectives of this study are to examine the applicability of waste slurry from soda ash manufacturing industries as a coagulant for the treatment of wastewater containing fine silica particles, and to reduce the cost of wastewater treatment containing silica. Acceptable water quality can be obtained with a little dosing of waste slurry by gelation before the coagulation process so it could be concluded that the waste slurry from soda ash can be used as a coagulant. Based on the results of experiments, the optimum pH of gelation for silica in wastewater was around five and the treatment process with the gelation of silica could reduce the chemical dosage and waste sludge after coagulation. Dewatering and settling characteristics of the floc after coagulation with the waste slurry are better than those of the floc after coagulation with the lime milk only.

  • PDF

Characteristics of the Flue Gas Desulfurization in $CaCo_3-CO_2-NH_3$ System ($CaCo_3-CO_2-NH_3$계에서의 배연탈황 특성)

  • 모세영;이경재;장홍기;손종렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.84-89
    • /
    • 1999
  • This experiment was performed to develop the new desulfurization process which can eliminate the possibility of generation of the secondary pollutants by regenerating the limestone from the sulfite/sulfate slurry generated from the wet lime/limestone flue gas desulfurization process by treating it with the ammonium hydroxide and carbon dioxide and using it again. In the experiments, regent grade calcium carbonate was dissolved to obtain the 200ml of sample slurry of the concentration of 2.0~0.4 weight percent. After three times of regeneration and desulfurization process, the coefficients of regeneration and desulfurization efficiencies are calculated/measured. The obtained results are that the coefficients of generation of the first. second, and third regenerated calcium carbonate were 90.88, 92.13, and 91.50%, respectively; and the desulfurization efficiencies of those are 93.4, 94.2 and 93.0%, respectively.

  • PDF

The required performance of the super flowing concrete for LNG (LNG tank용 초유동 콘크리트의 배합설계)

  • 권영호;전성근;백승준;이용일;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.463-468
    • /
    • 1999
  • The slurry wall of Inchon LNG receiving terminal tank will be planned the super flowing concrete having properties of high strength (required strength 520kg/$\textrm{cm}^2$), no-vibrating and massive structure in the underground. For the performance of this concrete, we investigate and select all materials, the optimum mix design and sensibility test in the laboratory. As test results, we choose portland blast-furnace slag cement and lime stone powder(L.S.P) as cementitious materials, W/C 41%(W/B 35.4%), S/a 50.8% and unit volume of coasre aggregate 0.30 as optimum mix design. Also test result of the fresh and hardened concrete are satisfied with specifications of slurry wall.