• Title/Summary/Keyword: Lightscape Program

Search Result 8, Processing Time 0.03 seconds

A Study on the exactitude of simulation tool by using Illuminate formula - Focused on the comparing result of Point method and Lightscapet - (조명공식을 이용한 시뮬레이션도구의 정확성에 관한 연구 - 점조도 공식과 Lightscape 결과 비교를 중심으로 -)

  • Kim, Chul-Hoon;Lee, Jung-Wook
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.240-243
    • /
    • 2006
  • This thesis is a study on the exactitude of Simulation Tool by using illuminate formula. Lightscape looks like general 3d program, but is a lighting simulation program that set up the properties of materials and light-sources about the model. This thesis calculates illuminance by a formula and simulates a light simulation using Lightscape for two luminaires data in space of ideal environment. As then each value was compared. As a result we got an error under 1% on the whole.

  • PDF

Daylighting Performance Evaluation of Lightshelf Window System by Lightscape (Lightscape를 이용한 광선반 창호시스템의 채광성능평가)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.45-52
    • /
    • 2004
  • Simulation of daylighting by computer program is a method to avoid unnecessary efforts in manufacture of its testing models, to reduce its measuring tolerances and be able to provide variations of various weather conditions as well. Many simulation programs on daylighting have been released freely or commercialized for selling, however, a demonstration of their availability and validity as a tool for evaluating daylighting performance is required since each one has its own characteristics. The objectives of this study lie in suggesting an application method of evaluation tools and demonstration of limits and characteristics so as to more easily determine the daylightingperformance in the very initial stages of planning for an arbitrary office space in which windows with daylight access are built. We produced scale model of the general light inducing type side lighting with lightshelfand ceiling, and the luminance (at 78 measuring points) and illuminance (at 84 measuring points) were measured in a clear sky. And a comparison of the measured values and the calculated values from a computer simulation using the Lightscape program was performed.

The proper way to use lighting simulation program through the lightscape. (Lightscape을 통한 조명프로그램의 올바른 사용)

  • 홍성욱
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.53-57
    • /
    • 2002
  • 조명프로그램에 대하여 널리 알려진 지금, 조명프로그램의 올바른 사용법 및 적용데이터의 중요성에 대하여 알아보려 한다. 조명프로그램을 실행하기 위한 최소한의 데이터는 "등기구 배광곡선 데이터"와 "마감재표면 속성 데이터"이다. 이번 논문에서는 적용되는 조건의 변경으로 어떠한 결과의 차이가 발생되는지 알아보고, 정확한 조명데이터의 축적과 적용의 중요성을 알아보겠다. 축적과 적용의 중요성을 알아보겠다.

  • PDF

The Study of the Most Suitable Location of Luminaire for Road Tunnel Lighting System (도로터널에서 최적의 조명기구 위치 연구)

  • 한완모;장우진;이인환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • As we know, topography of korea is composed of many mountains. Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program). As a result of research, mounting luminaires on the ceiling are better than wall because uniformity is more regular and utilization factor is also higher and then brightness is adequate as well, whereby installation on the ceiling is economical. Therefore, it is suitable that luminaires are installed on the ceiling in tunnel than wall.

The study on the Exterior Lighting Database by Computer Simulation (컴퓨터 시뮬레이션을 통한 경관조명 데이터베이스 구축에 대한 연구)

  • 김회서;이성주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.1-6
    • /
    • 2002
  • The purpose of this study was to develop an exterior lighting design database system for building lighting design. This database system has been designed to work internet web service as a design tool for architect and architecture student who are not profession of lighting design. In this study, exterior lighting database system has been accumulated with rendering image of each building from and lighting projector placement.

The Study of the Most Suitable Location of Luminaire for Road Tunnel Lighting System (도로터널에서 최적의 조명기구 위치 연구)

  • 한완모;장우진;이인환
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.25-29
    • /
    • 2003
  • As we know, topography of korea is composed of many mountains Also, the volume of traffic is increasing more and more nowadays. So, many tunnels are being constructed to reduce cost of transport and time. Thus, tunnel illumination was considered as the most important thing to make safe traffic conditions. In the past, we installed luminaires on the wall in tunnel, but currently we are installing those on the ceiling. Wherever luminaires are installed on the ceiling, the electric designer may not have known the proper point to install luminaires. Therefore, we researched this project to resolve above problems with abundant experience and accurate data through simulation(Lightscape program).

  • PDF

The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program (시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가)

  • Jeong, Yeol-Wha;Lee, Seun-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

Visual Performance Evaluation Study of a Scaled Light-Shelf Model (축소모형을 이용한 광선반의 시환경 특성 평가 연구)

  • Cho, Yil-Sik;Kim, Byoung-Soo;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.