• Title/Summary/Keyword: Lightning strikes

Search Result 54, Processing Time 0.019 seconds

광대역 접지임피던스 측정기의 설계

  • Park, Dae-Won;Jang, Un-Yong;Cha, Hyeon-Gyu;Gil, Gyeong-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.26-26
    • /
    • 2010
  • Line to ground faults or lightning strikes in electrical power systems produce high frequency overvoltages. With this reason, a wide band analysis of the ground impedance is necessary. In the paper, design of a wideband ground impedance meter which can measure the ground impedance in ranges from 65 Hz to 1.5 MHz is described. Also, a noise elimination method by a digital band-pass filter during measurement is proposed. The maximum measurement error of the meter is estimated 3 % in full ranges.

  • PDF

A Measurement of Switching Surge Voltage Using Inverter devices (인버터의 스위칭 서지전압 측정)

  • Kim, Jong-Gyeum;Jeong, Jong-Ho;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.14-21
    • /
    • 2004
  • Most adjustable-speed drives (ASDs) designed to operate low voltage induction motors incorporate voltage-source inverters (VSIs), which create motor voltages at high switching frequencies. The motor leads used to connect an ASD to a motor can behave like transmission lines for voltage pulses, which can be reflected at the motor terminals. The resulting oscillatory transient, known as the long-lead effect, can stress and consequently degrade the stator insulation system of a motor. This paper describes the results of tests to 1) determine the correlation between peak motor voltage and the length of motor leads and 2) determine the correlation between peak motor voltage and the switching frequency of the ASD Insulation failures like this usually are caused by voltage surges. Voltage surges are often the result of switching power circuits, lightning strikes, capacitor discharges and solid-state power devices.

A Measurement of Switching Surge Voltage using Voltage Type Inverter (전압형 인버터 스위칭 서지전압 측정)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.16-21
    • /
    • 2002
  • Most adjustable-speed drives(ASDs) designed to operate 220[V] induction motors incorporate voltage-source inverters (VSIs), which create motor voltages at high switching frequencies. The motor leads used to connect an ASD to a motor can behave like transmission lines for voltage pulses, which can be amplified (reflected) at the motor terminals. The resulting oscillatory transient, known as the long-lead effect, can stress and consequently degrade the statorinsulation system of a motor. This Brief describes the results of tests to 1) determine the correlation between peak motor voltage and the length of motor leads and 2) determine the correlation between peak motor voltage and the switching frequency of the ASD Insulation failures like this usually are caused by voltage surges. Voltage surges are often the result of switching power circuits, lightning strikes, capacitor discharges and solid-state power devices.

  • PDF

Analysis of Overvoltage and Reduction Methods of Insulation Joint Box in Underground Power Cable Systems (지중송전케이블계통에서 절연통의 과전압 해석 및 억제대책 검토)

  • Hong, Dong-Seok;Jeong, Chae-Gyun;Lee, Jong-Beom;Seo, Jae-Ho;Jo, Han-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.102-108
    • /
    • 2002
  • This paper describes the overvoltage analysis and reduction methods of insulation joint boxes in underground transmission power cables when direct lightning surge strikes to overhead transmission line. An actual 154kV combined transmission line with underground Power cables was modelled in ATPDraw for simulation. Simulations were performed to analyze the overvoltage between insulation joint boxes, sheath-to-ground voltage according to the distance between cable conductors, cable lengths, burying types, CCPU connection types. The most effective method to reduce the induced overvoltage of Insulation joint boxes was proposed. It is evaluated that the proposed reduction method riven from the detailed simulations can be effectively applied to the actual underground power cable systems.