• Title/Summary/Keyword: Lightning frequency

Search Result 148, Processing Time 0.028 seconds

An Automatic Measuring System of the Electric Fields Produced by Lightning Strokes (뇌방전에 의하여 발생하는 전장의 자동측정시스템)

  • Lee, Bok-Hee;Ahn, Chang-Hwan;Kil, Gyung-Suk
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.47-54
    • /
    • 1996
  • This paper deals with the electric field sensor and automatic measuring system of the time-varying space electric field produced by lightning discharges. The theoretical principle and the design rule of the measuring devices are investigated, and the semisphere-type electric field sensor and the signal process system are fabricated. From the calibration experiments, the frequency bandwidth of the measuring system ranges from 200 [Hz] to 1.56 [MHz] and the sensitivity is 0.96 [m V/V/m] as the amplification gain is 10. In addition, the electric field waveforms produced by lightning discharges are observed by the proposed electric field measuring system from June to August in 1995. The data is sampled with the time interval of 200 [ns] and is automatically recorded by transient signal analyzer(Necolet Pro 30), the resolution of which is 12 bit. And it is registered at personal computer. The electric field waveforms produced by intracloud discharge tend to be bipolar, with two or three narrow and fast rising pulses superimposed on the initial half-cycle.

  • PDF

Ubiquitous Sensors for Supervision of Power Facilities in Overhead Power Distribution Lines (가공배전선로의 전력설비 감시를 위한 유비쿼터스 센서)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.59-65
    • /
    • 2007
  • Recently, ubiquitous sensor network(USN) techniques have been applied to electric power facility management. This paper dealt with the designed and fabricated ubiquitous sensors which monitor transformers and lightning arresters installed in overhead distribution systems. The sensors consist of a 8-[bit] microprocessor unit, a wireless communication nodule specified in IEEE 802.15.4, and associated electronics. A Rogowski coil was fabricated to measure load of transformer and surge current without saturation having good linearity up to 1000[A]. A zero-phase current transformer with a high relative permeability of $10^5$ at 180[Hz] was used to detect small leakage current of $50[{\mu}A]{\sim}1[mA]$ flowing lightning arrester, and the frequency bandwidth of the module is ranges from 12[Hz] to 1.24[kHz] at -3[dB].

A Study on the Design of Varistor Prevented from Thermal Runaway to Improve Safety (안정성 개선을 위해 열폭주 방지 기능을 내장한 배리스터 설계에 관한 연구)

  • Jung, Tae-Hun;Shin, Hee-Sang;Cho, Sung-Min;Lee, Hee-Tae;Lee, Jun-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Recently, the natural environment changes drastically and the frequency of occurrence for lightning has gradually been increased. Such lightning delivers high volume of energy along the power line and communication line to the equipment in use. The high volume of energy arising from the lightning surge develops in fast velocity to destroy the facilities in power source and many other facilities in operation in sequential destruction with vast energy. This paper examines the characteristics of ZnO varistor to prevent from thermal runaway. We carry out performance evaluation of electrical characteristics on ZnO varistor. we will develop ZnO varistor Prevented from thermal explosion using test result of this paper.

Comparative Analysis on Ground Impedance for a Carbon Block and a Copper Rod (탄소블록과 동봉의 접지임피던스 비교 분석)

  • Seo, Jae-Suk;Park, Hee-Chul;Kil, Gyung-Suk;Oh, Jae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.472-477
    • /
    • 2013
  • This paper carried out the comparative analysis on ground impedance of a carbon block and a copper rod. Two types of grounding electrode were compared ; a carbon block (L : 1 m, ${\Phi}$ : 245 mm) buried at a depth of 0.8 m and a three-linked copper rod (L : 1 m, ${\Phi}$ : 10 mm) of equilateral triangles with 1 m spacing. Ground impedance depending on applied current source was evaluated by the application of a sine wave current with 60 Hz ~ 3.5 MHz, a fast-rise pulse with rising time of 200 ns, a standard lightning impulse of $8/20{\mu}s$ and a 600 Hz square wave. Ground impedance for both electrodes were almost the same value below 100 kHz, and increased rapidly afterwards. The maximum ground impedance appeared $400{\Omega}$ at around 1.5 MHz. Ground impedance of the carbon block was lower at the square wave and was higher at fast-rise pulse than that of the copper rod. Also, ground impedance as ages showed no difference for the last 8 months. From the results, it is likely that ground performance for both electrodes shows no difference against commercial frequency and lightning impulse current, while the copper rod shows better performance against a fast-rise pulse with rise-time of a few hundred ns.

Study on the Elimination of Residual Voltage in Quarter Wave Short Stub Surge Arrestor (4분의 1 파장 단락 스터브 방식 서지 어레스터의 잔여 전압 제거에 관한 연구)

  • Kim, Yeon-Tae;Won, Tae-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.8
    • /
    • pp.33-44
    • /
    • 2000
  • The lightning with high voltage and current can enter the basestations for mobile communication through their antenna. The device which can protect the basestation against the lightning, is surge arrestor. In this paper, the concept, kind, operating mechanism, design and fabrication of surge arrestor were studied. Based on the studied data, variable surge arrestors were designed for the current mobile communication service like a cellular, GSM and PCS and the next generation mobile communication like a IMT-2000. Computer simulation for the prediction of their characteristics and inner structure optimization for the improvement of their electrical characteristics were carried with high frequency 3D structure simulator. Quarter wave short stub surge arrestors for IMT-2000 were fabricated with their final design and then the measurement of electrical characteristics and the lightning test were executed. As a results of measurement, we obtained below 1.05 of VSWR, -0.035 dB of insertion loss, -150 dBc of intermodulation and 7∼ll V of residual voltage.

  • PDF

Residual Voltage Reduction of Coaxial Surge Arrestor Using Ceramic Filler (세라믹 필터를 이용한 동축 서지어레스터의 잔류전압 저감)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.46-53
    • /
    • 2007
  • Extension of the mobile communication and the rapidly developing services connected with wireless multimedia(W-CDMA, DMB, Wibro, and so on) need great many base station transceiver systems, antennas, and many signal transmission line to embody these services. The min communication appliances system is exposed always in danger of transient overvoltage by direct stroke or induced lightning surge flowing in through antenna because the antenna of base station transceiver system or relay equipment is combined with expensive communication network equipments through signal transmission line. Now, gas discharge tube(GDT) or narrow band stub arrestor which is used by the surge protector for communication use is exposing limitations as for lightning surge protective means of the communication facility with high speed and wide frequency band. Therefore, for improving performance of surge arrestor, we applied ceramic filter which can reduce lightning surge invading from antenna effectively, and proved that ceramic filter is effective in residual voltage reduction through the experimental research.

Analysis for the Grounding Impedance of Vertical Grounding Electrodes using the Distributed Parameter Circuit Model (분포정수회로모델을 이용한 수직 접지전극의 접지임피던스의 분석)

  • Lee, Bok-Hee;Kim, Jong-Ho;Choi, Jong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1103-1108
    • /
    • 2010
  • A grounding electrode has the transient grounding impedance characteristics against lightning surges. So the performance of grounding electrodes should be evaluated as a grounding impedance as well as the ground resistance. The frequency-dependent grounding impedance is varied with the shape and size of grounding electrode and is divided into both inductive and capacitive behaviors. This paper presents a theoretical analysis for the grounding impedance determined by the size of grounding electrode using the distributed parameter circuit model. EMTP and Matlab programs were used in calculating the frequency-dependent grounding impedances of vertical grounding electrodes. It was found that the frequency-dependent grounding characteristics of vertical grounding electrodes are characterized by the distributed parameters which are changed in the dimension of grounding electrodes.

Heavy ion effects on mode conversion between electron and proton whistlers : A simulation study

  • 김은화;이동훈
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.37-37
    • /
    • 2003
  • Electron whistlers frequently excite proton whistlers. The proton whistlers appear on the dynamic spectrum as rising tones, which start after the reception of a short electron whistler, asymptotically approaching the local proton gyro-frequency. The proton whistlers are dispersed forms of lightning impulses and their dispersion can be explained by the effects of heavy ions such as H+ and He+ on the propagation of an electromagnetic wave in the ionosphere. In the ionosphere, a right-handed circularly-polarized electron whistler becomes coupled to a left-handed circularly-polarized proton whistler when the frequency becomes close to a cross-over frequency. By adopting the multi-fluid numerical wave model, we examine how the mode coupling varies as the ion composition changes along altitude in the mid-latitude ionosphere. The time histories and dynamic spectra of electric fields are presented. In addition, we compare our results with the previous theoretical and observational studies.

  • PDF

Defective Porcelain Insulator Inspection Based on Harmonic Retrieval (고조파 추출을 이용한 불량애자 검출장치 개발연구)

  • Lu, Hao;Jin, Hong-Zhe;Han, Sun-Sin;Lee, Jang-Myung
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.291-292
    • /
    • 2007
  • Porcelain insulators are widely used in overhead high-voltage power transmission lines while providing adequate insulation to withstand switching and lightning over voltages. For the safety consideration, we proposed a novel insulator inspection method using harmonic, which is retrieved from the low frequency signal. The working principle of this new method is based on the relationship between the low frequency harmonic and the defective characteristic of the insulators. So, in this paper, the harmonic retrieval in the complex noise is solved with the HOC (High Order Cumulants) is extended. In the experiment, as one of our dedicated contribution, we illustrate low frequency harmonic and the defective characteristics of the porcelain insulators.

  • PDF

Phenomenon of Power Interference and Screening Factor (전력유도 현상과 차폐계수)

  • 황종선;김영민;이경욱;김재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF