• 제목/요약/키워드: Lightning frequency

검색결과 148건 처리시간 0.022초

가변주파수 및 임펄스 전류를 이용한 과도접지임피턴스 분석 (An Analysis Method for the Transient Ground Impedance Using Variable Frequency Current and Lightning Impulse)

  • 조성철;엄주홍;이태형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 2007
  • This paper presents an analysis method of transient ground impedance using the lightning impulse and variable frequency currents. The transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient impedance of the grounding system. There are some differences between the effective impulse ground impedance which was introduced some papers and the transient ground impedance. The transient ground impedance measured from the peak value of impulse voltage and the peak value of impulse current is more reliable than the effective impulse ground impedance.

  • PDF

전류구동형 서지카운터 (Current Driving Type Surge Counter)

  • 이복희;안창환;장석훈;정관모;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1712-1714
    • /
    • 1997
  • This paper deals with the surge counter drived by lightning and switching currents. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. In this paper, for the purpose of protecting the electronic circuits and counting the occuring frequency, the current driving type surge counter is designed and fabricated. The surge counter consists of surge protective divices, current detector, metal oxide varistor(MOV), rectifier, capacitor, and electromagnetic counter. This surge counter is able to count the occuring frequency of surges and to clamp lightning surge current. To evaluate the performance of the surge counter, impulse voltage and current were applied at the surge counter by the surge generator. As a result, applied surges were exactly counted and clamped.

  • PDF

탄소접지극 접지임피던스의 주파수의존성과 과도응답특성의 해석 (Analysis of Transient Response Behavior and Frequency-Dependent Ground Impedances of the Carbon Ground Electrodes)

  • 이복희;이강수;김유하;엄상현
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.54-61
    • /
    • 2013
  • This paper presents transient response behavior and frequency-dependent ground impedance of a single carbon ground electrode. The ground impedance of the carbon ground electrode was measured as a function of frequency of injected currents and simulated by using the distributed parameter circuit model with due regard to the frequency-dependent soil parameters, and the transient response behavior of the carbon ground electrode against impulse currents were investigated. As a consequence, the frequency-dependent ground impedance of the carbon ground electrode showed the capacitive behavior, that is, the ground impedance decreases with increasing the frequency of injected currents and lowers at the fast front time of impulse current. It was found that the carbon ground electrode is effective in grounding system for lightning protection. The ground impedance simulated with due regard to the frequency-dependent soil parameters was in good agreement with the measured data. The adequacy of the simulation technique and the distributed parameter circuit model for the carbon ground electrode was verified. It is expected that the simulation methodology, which analyzes the frequency-dependent ground impedance of the carbon ground electrode proposed in this work, can be used in the design of a grounding system for protection against lightning.

Effective Impulse Impedances of Deeply Driven Grounding Electrodes

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong;Chang, Keun-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.207-214
    • /
    • 2004
  • This paper presents the characteristics of transient and effective impulse impedances for deeply driven grounding electrodes used in soil with high resistivity or in downtown areas. The laboratory test associated with the time domain performance of grounding piles subjected to a lightning stroke current has been carried out using an actual-sized model grounding system. The ground impedances of the deeply driven ground rods and grounding pile under impulse currents showed inductive characteristics, and the effective impulse ground impedance owing to the inductive component is higher than the power frequency ground impedance. Both power frequency ground impedance and effective impulse ground impedance decrease upon increasing the length of the model grounding electrodes. Furthermore, the effective impulse ground impedances of the deeply driven grounding electrodes are significantly amplified in impulse currents with a rapid rise time. The reduction of the power frequency ground impedance is decisive to improve the impulse impedance characteristics of grounding systems.

한반도 호우유형의 중규모 특성 및 예보 가이던스 (Mesoscale Features and Forecasting Guidance of Heavy Rain Types over the Korean Peninsula)

  • 김선영;송환진;이혜숙
    • 대기
    • /
    • 제29권4호
    • /
    • pp.463-480
    • /
    • 2019
  • This study classified heavy rain types from K-means clustering for the hourly relationship between rainfall intensity and cloud top height over the Korean peninsula, and then examined their statistical characteristics for the period of June~August 2013~2018. Total rainfall amount of warm-type events was 2.65 times larger than that of the cold-type, whereas the lightning frequency divided by total rainfall for the warm-type was only 46% of the cold-type. Typical cold-type cases exhibited high cloud top height around 16 km, large reflectivity in the upper layer, and frequent lightning flashes under convectively unstable condition. Phenomenally, the cold-type cases corresponded to cloud cluster or multi-cell thunderstorms. However, two warm-type cases related to Changma and typhoon were characterized by heavy rainfall due to long duration, relatively low cloud top height and upper-level reflectivity, and the absence of lightning under the convectively neutral and extremely humid conditions. This study further confirmed that the forecast skill of rainfall could be improved by applying correction factor with the overestimation for cold-type and underestimation for warm-type cases in the Local Data Assimilation and Prediction System (LDAPS) operational model (e.g., BIAS score was improved by 5%).

토양의 주파수의존성을 고려한 정보통신설비용 수평접지전극의 과도전위상승 분석 (Analysis of Transient Potential Rises of Horizontal Ground Electrodes Considering the Frequency-Dependent of Soil)

  • 안창환
    • 전자공학회논문지
    • /
    • 제53권2호
    • /
    • pp.147-153
    • /
    • 2016
  • 정보통신설비의 피뢰설계는 정보통신기기 동작의 신뢰성을 향상시키기 위해서 매우 중요한 요소이다. 특히, 뇌격전류에 의한 접지전극의 과도전위상승은 전원설비 및 정보통신기기의 절연내력의 기초 자료가 되기 때문에 정확한 해석이 요구된다. 접지전극의 과도전위상승은 접지임피던스로부터 계산되어지며, 접지임피던스는 접지전극의 형상과 토양의 주파수의존성에 크게 의존적이다. 토양의 주파수의존성은 인가된 전계에 의한 토양의 유전체 특성을 해석할 수 있는 디바이식을 적용하였다. 또한 접지임피던스로부터 과도전위상승을 계산하는 방법을 제시하였다. 디바이식을 적용한 과도전위상승 결과를 분석하기 위해서 전송선로 모델과 대지저항률이 일정한 경우에 대해서 각각 시뮬레이션을 수행하였다. 수평접지전극은 30 m이며, 표준 뇌격전류파형에 대해서 대지저항률이 10, 100, $1000{\Omega}{\cdot}m$에 대해서 각각 분석하였다. 그 결과 디바이식을 적용하여 계산된 수평접지 전극의 과도전위상승이 다른 모델의 경우보다 더 낮게 나타났다.

뇌서지가 ZnO바리스터에 미치는 영향 (Effects of Lightning Surges on the Life of ZnO Varistors)

  • 이봉;이수봉;강성만;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

MATLAB 프로그램을 이용한 배전계통에 사용되는 동봉 접지전극의 과도 접지임피던스 특성 분석 (Transient Grounding Impedance Characteristic Analysis of a Copper Rod-type Grounding Electrode Used for Electric Distribution Systems Using MATLAB Program)

  • 김경철;오경훈;이규진;심건보;최종기
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.40-46
    • /
    • 2009
  • 비록 접지저항은 접지전극의 접지성능을 좌우하는 지수이기는 하지만, 과도상태에서는 접지 성능을 반영하지 못한다. 동봉은 배전계통에서 가장 많이 쓰이는 접지전극이다. 본 논문에서는 동봉의 접지 임피던스를 주파수 60[Hz]에서 100[kHz] 범위까지 측정하여 등가 접지임피던스 모델을 구하였다. 뇌격서지가 유입되었을 때 MATLAB 프로그램으로 과도접지임피던스의 수치와 파형을 시뮬레이션하였다.

임펄스전류에 의한 인하도선 주위에서 자속밀도의 분포 (Distributions of the Magnetic Flux Density Near Down-Conductors Due to Various Impulse Currents)

  • 이복희;장근철;이수봉;강성만;이승칠
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권2호
    • /
    • pp.109-115
    • /
    • 2004
  • This paper deals with the behaviors of magnetic flux density near down-conductors by lightning currents. The background on the principle of magnetic flux density measurements using the RL self-integrating magnetic field sensor was described. The magnetic flux density measuring device consisting of RL self-integrating magnetic field sensor and differential amplifier was designed and fabricated. The frequency bandwidth of the magnetic flux density measuring system ranges from 200 Hz to 300 KHz and the response sensitivity was 0.126 $\mu$T/㎷ The distributions of the magnetic flux density near down-conductors due to impulse currents with various rise times were analyzed as a parameter of the bonding conditions and materials of conductor and wiring conduits. The magnetic flux density due to impulse currents was inversely proportional to the distance between the down-conductor and measuring point. The amplitude of the magnetic flux density for PVC Pipe with down-conductor was 72 $\mu$T/㎷ at the distance of 1m and was higher than for steel conduits and coaxial cable. Finally the magnetic flux density is increased with increasing the di/dt it and oscillation frequency of lightning currents in this experimental ranges.

애자의 소음 분석을 통한 애자 고장 탐지 가능성 연구 (A Study on Possibility of Detection of Insulators' Faults by Analyses of Radiation Noises from Insulators)

  • 박규칠;윤종락;이재훈
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.822-831
    • /
    • 2009
  • 애자는 송전선 시스템에서 전기적으로나 기계적으로 매우 중요한 소자이다. 송전선 시스템에 설치된 이후 애자의 열화 등에 의해 고장이 난 애자를 찾아내기 위해 애자로 부터의 방사 소음을 측정하여 분석하였다. 대상으로 한 제품은 2종류의 현수 애자, COS, 2종류의 Line Poster, 피뢰기이며, 이들 제품의 정상 상태와 고장 상태의 방사 소음을 각각 측정하여 시간 파형, 주파수 스펙트럼, 피크 검출의 결과를 서로 비교하여 그 차이점을 제시하였다. 또한, 이를 바탕으로 방사 소음으로부터 고장 상태의 애자의 검출의 가능성 및 그 방법을 제시하였다.