• Title/Summary/Keyword: Lightning breakdown voltage

Search Result 63, Processing Time 0.034 seconds

A Numerical Approach for Lightning Impulse Flashover Voltage Prediction of Typical Air Gaps

  • Qiu, Zhibin;Ruan, Jiangjun;Huang, Congpeng;Xu, Wenjie;Huang, Daochun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1326-1336
    • /
    • 2018
  • This paper proposes a numerical approach to predict the critical flashover voltages of air gaps under lightning impulses. For an air gap, the impulse voltage waveform features and electric field features are defined to characterize its energy storage status before the initiation of breakdown. These features are taken as the input parameters of the predictive model established by support vector machine (SVM). Given an applied voltage range, the golden section search method is used to compute the prediction results efficiently. This method was applied to predict the critical flashover voltages of rod-rod, rod-plane and sphere-plane gaps over a wide range of gap lengths and impulse voltage waveshapes. The predicted results coincide well with the experimental data, with the same trends and acceptable errors. The mean absolute percentage errors of 6 groups of test samples are within 4.6%, which demonstrates the validity and accuracy of the predictive model. This method provides an effectual way to obtain the critical flashover voltage and might be helpful to estimate the safe clearances of air gaps for insulation design.

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

Experimental investigations of Breakdown Phenomena in Soils in the vicinity of Ground rod (봉형접지전극 주변에서 토중방전현상에 대한 실험적 고찰)

  • Lee, Bok-Hee;Kim, Byoung-Gun;Lee, Woo-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.279-282
    • /
    • 2005
  • Morden electronic equipments are becoming very important in information oriented society, but they are vulnerable to lightning surges. Soil resistivity in the vicinity of grounding electrodes my be affected by the current flowing from the grounding electrodes into the surrounding soil. Electrical conduction in soils depends on the grain size, compactness, and variability of the grain sizes. When a high current is injected into the soil, and the breakdown phenomenon occur. In the present work, Electrical behaviors related to discharge in soils were investigated. The breakdown voltages in soil were lower than that sparkover voltage in air. The breakdown voltage in the gravel layer is relatively low, and the breakdown was caused by the flashover through the surface of gravels

  • PDF

Study on Insulation Prediction of Triple Junction in $SF_6$ ($SF_6$ 가스 중의 삼중점 절연파괴 예측기술에 관한 연구)

  • Cho, Yong-Sung;Chong, Jin-Kyo;Lee, Woo-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.989-993
    • /
    • 2009
  • Triple junction which consists of three media(electrode, insulator, and gas) should be considered in designing of high voltage equipments due to the electric field enhancement. In this paper, positive lightning impulse breakdown voltage is predicted based on the streamer theory for simplified insulator models and 72.5kV spacer with varying the triple junction geometry and gas pressure, and the results are compared to the experimental results. The electric field coefficient concept is also applied in order to evaluate the partial discharge inception voltage and the surface flashover voltage from the streamer inception voltage. The application of this method using the constant electric field coefficient of 1.3 and 0.66 is possible for evaluating the triple-junction insulation of the simplified insulator and the 72.5kV spacer respectively. The error rate is under 10%.

Voltage Time characteristic of electrical breakdown in $SF_6$ ($SF_6$ 가스중 V-t절연파괴특성)

  • Seo, Kil-Soo;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1770-1772
    • /
    • 1997
  • In this paper, Voltage-time characteristics of lightning impulse and switching surge breakdown in SF6 is studied on the gap and various pressure. The characteristics is categorized into three pattern depending on the configuration of the gap and gas pressure. The properties of the voltage-time characteristics in these patterns are generalized as semi-empirical formula which will be useful in the quantitation voltage evaluation of insulation coordination and the abnormal voltage protection of SF6 insulated power equipment.

  • PDF

Investigation on the Dielectric, Physical and Chemical Properties of Palm Oil and Coconut Oil under Open Thermal Ageing Condition

  • Mohamad, Nur Aqilah;Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Yunus, Robiah;Ishak, Mohd Taufiq;Yaakub, Zaini
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.690-698
    • /
    • 2016
  • In this paper, a study is carried out to investigate the dielectric, physical and chemical properties of Palm Oil (PO) and Coconut Oil (CO) under open thermal ageing condition. The type of PO used in this study is Refined Bleached and Deodorized Palm Oil (RBDPO) Olein. The ageing experiment was carried out at 85 ℃ and 115 ℃ for 1, 3, 5, 7 and 14 days. Several parameters were measured such as AC breakdown voltage, dielectric dissipation factor, relative permittivity, resistivity, viscosity, moisture and acidity throughout the ageing duration. Based on the study, it is found that there are no significant changes on the AC breakdown voltages and relative permittivities for both RBDPO and CO. At ageing temperature of 115℃, there are clear reduction trends of dielectric dissipation factor for CO and resistivities for most of RBDPO. On the other hand, no clear trends are observed for viscosities, moisture and acidities of RBDPO and CO throughout the ageing duration.

A Fundamental Study on the Impulse Responses of Ground Rod Attendant upon Soil Discharges (토중방전을 수반하는 접지봉의 임펄스응답에 대한 기초적 연구)

  • Yoo, Yang-Woo;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.62-69
    • /
    • 2014
  • This paper deals with the fundamental characteristics of transient and conventional ground impedances associated with soil discharges when the lightning impulse voltage was applied to a small-sized ground rod. The potential rise responses of the test ground rod to impulse currents were observed. The current-voltage (I-V)curves, transient and conventional ground impedance curves were examined.. To analyze the transient behaviors of ground rod attendant upon soil discharges, the impulse responses of ground rod were compared with those of non-inductive resistor. As a consequence, the potential rise and impedance of ground rod were reduced and the currents dispersed into the earth were increased due to soil discharges near the ground rod. Soil discharges are classified into two regimes; ionization and breakdown phenomena. The potential rise and impulse impedance of ground rod are significantly decreased by breakdown processes in soil.

Safety Analysis of Carbon Composite-body Against Lightning Strikes (탄소섬유 복합차체의 낙뢰에 대한 안전성 분석)

  • Kim, Sung-Wook;Park, Dae-Won;Kil, Gyung-Suk;Mok, Jae-Kyun;Han, Ju-Seop
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.321-326
    • /
    • 2008
  • Light weight of vehicles by composite materials makes possible high speed, energy saving, and low repair cost. As Bimodal Tram and Tilting Train eXpress(TTX) use carbon composite material for their bodies, safety for passengers and electrical devices against unexpected failures has been issued more than ever. Lightning strike which generates high voltages and large currents is the worst case for the safety of passengers and devices. With this background, we experimentally investigated the insulation breakdown phenomena on carbon composite materials by the application of lightning surge voltage and current. From the experimental results, we could estimate whether the composite body is safe or not for the inside passengers and devices against lightning strikes.

  • PDF

Study on the Effect of Parallel Ground Conductor at the Single Point Bonding in Underground Transmission System (지중송전 편단접지개소에서의 병행지선 설치효과 검토)

  • Kang, J.W.;Park, H.S.;Yoon, H.H.;Yoon, J.K.;Bae, J.H.;Suk, K.H.;Oh, J.M.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.736-737
    • /
    • 2007
  • The single point bonding in underground transmission system can induce high voltage on the sheath when ground fault, lightning serge and switching serge occurs, at that time underground cable systems cannot offer a return path of fault current. Accordingly if fault current, which cannot return to ground, flows at the single point bonding, high voltage can be induced in SVL and that voltage can cause aging and breakdown of SVL. Therefore this paper study on the effect of parallel ground conductor at the single point bonding when ground fault and lightning serge occurs by using ATPDraw.

  • PDF

A Study of LA Counter Over-activation in AC Electric railway Substation (AC 전철변전소의 피뢰기카운터 과동작에 관한 연구)

  • Cheon, Hee-Seung;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.132-139
    • /
    • 2008
  • In an electric railway feeding system, transient over-voltage often appears due to the feeder's direct lightning and induced lightning, while switching over-voltage also frequently occurs during operation of electric feeding in substation facilities. Such over-voltage is several times larger than the regular power, and accordingly leads to the dieletric breakdown of eletric power products such as invasion transformers and circuit breakers. Arresters are installed to protect these machines, while arrester counters are installed to observe the arrester's activation. This thesis aims to explore the status of an arrester counter that is being activated several thousand times, determine whether the arrester has actually been activated in relation to the counter, and investigate the over-heatedness and risks of the arrester.

  • PDF