• 제목/요약/키워드: Lightning Overvoltage

검색결과 93건 처리시간 0.028초

지중송전계통에서 OF 및 XLPE 케이블 혼용 연계 운용의 효용성 평가 (Effectiveness Evaluation on Combined Connection Operation of OF and XLPE Cable)

  • 채직병;이종범
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.857-863
    • /
    • 2015
  • OF cable with excellent reliability and economic efficiency, has been used as the main cable of underground transmission in Korea. However, as XLPE cable is excellent in view points such as reduction of loss, convenience on the construction/operation, and manufacturing technology, it has been replaced as instead of OF cable. Also, when the aging occurs in some sections of OF cable, the section is replaced as XLPE cable without changing of whole cable line. However, there are some differences like electrical constants between both types of cables. Therefore if underground transmission system will be operated as combined connection composited of both cables, it should be proved that overvoltage is stable in steady and transient state. This paper describes the effectiveness of connection operation in combined OF and XLPE cable. For the evaluation of effectiveness, some important analysis such as sheath component voltage, lightning and switching overvoltage, single line-to-ground fault are carried out in steady and transient state. EMTP/ATPDraw is used for modeling and analysis of system.

구내 통신용 보호기의 과전압 제한 성능 기준 개선 연구 (A Study on the Improvement of Technical Regulation for Overvoltage Performance of Telecommunication Protector in Customer Premises)

  • 고홍남;최문환;조평동
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.823-826
    • /
    • 2013
  • 구내 통신 선로에 유입되는 낙뢰나 유도에 의한 서지로부터 통신 설비 및 이용자를 보호하기 위하여 국선과 구내 케이블의 접속 지점에 외부로부터의 과전압 또는 과전류를 차단하기 위한 보호기를 설치하고 있다. 국내에서 이러한 보호기에 대한 설치 의무 및 성능 기준 등을 기술기준으로서 규정하고 있으나 현행 기술기준은 PSTN 서비스에 기반을 두어 수립된 기준으로 통신 기술의 발전에 따른 서비스의 다변화에 대응하고 있지 못하고 있다. 지난 연구에서 이러한 구내통신설비의 가입자 보호기 기술기준에 대한 개선 방향에 대한 제언을 한 바 있으며 이에 본 논문에서는 구내 통신용 보호기의 성능 기준 중 과전압 제한 성능 기준을 개정안을 마련하고 이의 검증을 위한 시험을 통해 개정안에 대한 타당성을 제시한다.

  • PDF

전원계통의 접지방식에 따른 서지보호기의 보호효과 (Protection Effects of Surge Protective Devices According to Types of system Groundings)

  • 이복희;이동문;강성만;이수봉
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.66-71
    • /
    • 2003
  • 소형의 반도체와 회로로 구성되어진 전자기기는 뇌과전압으로부터 ZnO 바리스터, 지너다이오드, 가스방전관과 같은 서지보호장치 (SPDs)에 의해 보호되고 있다. 그러나 SPD의 제한전압은 SPD의 설치방법에 따라 커다란 영향을 받는다. 본 논문에서는 전원계통의 접지방식에 따른 SPD의 보호효과에 대하여 실험적으로 검토하였다. 독립접지는 SPD의 설치방법에 있어서 그다지 바람직하지 않다. 또한 가스방전관보다 ZnO 바리스터의 한 점을 공통접지하는 것이 더 효과적이다. SPD의 단자에 공통접지하는 것이 SPD의 설치방법에 있어서 가장 효과적임을 제안하였다.

세라믹 필터를 이용한 동축 서지어레스터의 잔류전압 저감 (Residual Voltage Reduction of Coaxial Surge Arrestor Using Ceramic Filler)

  • 엄주홍;조성철;이태형;이영철
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.46-53
    • /
    • 2007
  • 현재 급속한 발전을 거듭하고 있는 이동통신 및 무선 멀티미디어 관련 서비스(W-CDMA, DMB, WiBro 등)의 확장은 이들 시스템을 구현하기 위한 수많은 기지국과 안테나 및 다수의 신호전송선로를 필요로 한다. 기지국 또는 중계시설의 안테나는 신호전송선로를 통하여 고가의 통신 네트워크 장비들과 결합되어 있으므로 주요 통신기기 시스템은 안테나를 통해 유입하는 직격뢰 및 유도뢰에 의한 순간적인 과전압의 위험에 항시 노출되어 있다. 현재 통신용 보호기로 사용되고 있는 가스방전튜브(GDT) 또는 협대역 스터브형 어레스터는 고속 광대역의 통신설비에 대한 뇌서지 보호수단으로서는 한계점이 드러나고 있다. 따라서 본 연구에서는 안테나를 통해 입사하는 뇌서지를 효과적으로 저감시켜주는 서지어레스터의 성능향상을 위해 세라믹 필터를 적용하였으며, 잔류전압 저감에 효과적임을 성능실험을 통해 입증하였다.

154kV 지중 방식층용 ZnO소자 및 서지 보호장치 성능 (The Performance of ZnO Varistors and Surge Protector for 154kV Underground Cable)

  • 조한구;한동회;윤한수;이종혁;장태봉;이형구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.248-250
    • /
    • 2001
  • The surge protector is crucial power apparatus to guarantee the safe operation of power transmission of underground cable which can effectively restrain the overvoltage and inductive lightning stroke in power system. This paper describes the results of a study on the performance of ZnO varistors and surge protector for 154 kV underground cable. And, the influence of water tight and insulating performance was evaluated through such as surge protector of the armored design.

  • PDF

내장 순시 트립장치를 이용한 MOV의 열폭주 보호와 SPD의 안전성 개선 (Protection of MOV Thermal Runaway and Safety Improvement of SPD using Built-in Instantaneous Trip Device)

  • 김주철;전주술;기채옥;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.120-125
    • /
    • 2011
  • SPDs are increasingly being used against lightning and switching surge according to the applicable revised standard and equipotential grounding system. SPDs are equipped usually with a MOV voltage regulating element. The MOV, however, always is exposed to the danger of thermal runaway resulting from inrushing temporary overvoltage and deterioration. In this paper, the authors made two prototype SPDs built-in Instantaneous trip device and analyzed their limiting voltage through test of the MOV breakdown. As the result of the analysis, the SPDs built-in Instantaneous trip device was proven to be effective for protecting MOV against thermal runaway and Instantaneous trip device react for limiting voltage is considered that is applicable to SPD.

지중배전선로용 피뢰기를 고려한 과도현상 해석 (Analysis of Transient Phenomena Considering Arrester in Underground Distribution Line)

  • 윤창섭;이종범;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.276-278
    • /
    • 2007
  • This paper describes the analysis to install an arrester for an underground distribution line effectively. Currently, the underground distribution cable is protected by the arrester connected with overhead distribution line. However, riser pole arrester can't protect all parts of cable like the end of the underground distribution cable. To solve this problem, we installed the arrester on each cable and have measured the overvoltage made by lightning surge in each situation. The location to get effective results has been decided from the measured voltage above.

  • PDF

GIL-가공송전선로 연계시 뇌써지에 의한 과전압 검토 (Overvoltage Analysis on GIL - Overhead Transmission Line by Lightning Surge Conditions)

  • 박흥석;장태인;강지원;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.143-144
    • /
    • 2008
  • 최근 국내에서 가스절연송전선(GIL: Gas Insulated Transmission Line)의 실계통 도입을 인하여 345kV급 GIL의 개발 및 적용을 위한 연구 및 검토가 수행되고 있다. 이 중의 하나가 가공송전선로 사이의 일부구간을 지중화 하여 GIL로 대치할 경우에 나타날 수 있는 써지에 의한 과전압의 검토이다. 가공선로의 일부구간을 GIL로 대치하는 데 있어서, 변전소 단이 원거리일 경우에는 변전소 내부의 차단기나 단로기 등 개폐 써지에 의한 과전압의 영향은 감쇄효과로 인하여 그다지 크지 않으며, 뇌써지에 의한 과전압이 주요 영향 요소로 작용하고 있다. 따라서, 본 논문은 뇌써지에 의한 GIL-가공선로 구간의 과전압을 검토하기 위하여 GIL과 인접한 가공선로 구간에 낙뢰가 유입된 경우를 가정하여 GIL에 발생되는 과전압 및 보호협조 방안을 분석한다.

  • PDF

500 kV 개스절연변전소의 BIL 결정을 위한 뇌과전압 해석 (Lightning overvoltage analysis of 500 kV GIS S/S for BIL selection)

  • 주형준;곽주식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.326-328
    • /
    • 2005
  • 500kV 개스절연 변전소의 절연협조의 기본은 이상전압의 억제와 동시에 설비의 중요도, 적용형태를 고려하여 설비의 사고확율을 어떤 허용수준이하가 되도록 기기의 절연 강도와 배치를 결정하는 것이다. 일반적으로 변전소 뇌과전압에 영향을 미치는 요소로는 모선 형태 및 구성, 피뢰기의 위치와 설치대수, 피뢰기의 제한 전압-전류특성, 모선의 길이, 피뢰기와 피보호기간의 이격거리 등이 있다. 이 논문에서는 500kV의 개스절연변전소의 기기 절연강도 결정을 위하여 뇌침입시 변전소의 뇌과전압을 EMTP로 모의하여 뇌격의 크기, 뇌격지점, 피뢰기위치와 설치 대수, 등에 따른 최대과전압을 모의하여 BIL(basic inpulse level)을 선정하였다.

  • PDF

400 kV급 상분리형 GIS의 기기 BIL 산정을 위한 뇌과전압해석 (Lightning overvoltage analysis of 400kV separated GIS for BIL selection)

  • 강연욱;곽주식;주형준;권동진;심응보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.323-325
    • /
    • 2005
  • 경제성장에 따른 인구의 집중화 및 도시기능의 고도화에 따라 전력기술분야의 많은 변화를 요구하게 되었다. 좁은 지역에 대용량의 전력을 안정적으로 공급하면서 환경과의 조화를 이루기 위하여 SF6개스를 이용한 개스절연개폐기(GIS)의 이용이 증가하였다. 이 논문에서는 중동국가에서 많이 건설되고있는 400kV 개스절연 변전소의 절연협조를 위하여 일반적으로 변전소 뇌과전압에 영향을 미치는 요소인 모선형태 및 구성, 피뢰기의 위치와 설치대수, 피뢰기의 제한 전압-전류특성, 모선의 길이, 피뢰기와 피보호기간의 이격거리 등을 고려하여 뇌침입시 변전소의 뇌과전압을 EMTP로 모의하여 개스절연변전소의 기기 절연강도를 결정하였다. 결정된 절연강도는 위의 모의결과로 얻어지는 발생예상 전압에 적정한 여유를 두고 IEC규격을 따라 선정하였다.

  • PDF