• Title/Summary/Keyword: Lightning Overvoltage

검색결과 93건 처리시간 0.021초

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2219-2220
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.587-588
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1253-1254
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge In the Underground Dlstrlbutlon Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1713-1714
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

과전압 분석 결과와 고장특성을 고려한 기설 송전선로의 절연보강 방법에 관한 연구 (A Study on Insulation Performance Enhancement of Existing Transmission Line Considering Overvoltage Analysis Result and Fault Characteristic)

  • 곽주식;우정욱;구교선;김경탁;권동진
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.162-168
    • /
    • 2009
  • 본 논문은 이미 표준 절연설계 값으로 건설되어 운전중인 송전선로의 절연거리를 과전압분석결과, 뇌사고 및 오손 고장 확률과 특성을 고려하여 재설계하고 소요 애자수량을 결정하기 위하여 수행된 연구결과이다. 송전선로의 절연성능을 훼손하지 않으면서 적절한 절연거리를 확보하기 위하여 EMTP 모델을 이용하여 선로에서 발생 가능한 최대 과전압을 계산하고, 뇌 고장실적 및 뇌사고율 예측계산결과와 오손 고장 확률을 조사 분석하였다. 분석결과로부터 고장 특성을 고려한 소요 애자수량의 결정방법을 제시한다.

혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석 (Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables)

  • 김병숙;이장근;한병성;이종범
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

해상 풍력발전단지에서 뇌격 시 서지어레스터 열화로 인한 연계 고장 분석 (A Study on the Consecutive Failure Due to Deterioration in Surge Arresters of the Offshore Wind Farm)

  • 김진혁;김규호;이재균;우정욱
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1265-1270
    • /
    • 2018
  • One of the ways to improve the stability of power facilities used in power systems is to use power surge arresters and to protect against transient overvoltages and surges in normal operation. Also it is important to reduce the impact of lightning strikes because lightning can create overvoltage in the grid of the wind turbine and affect power quality. So This paper analyzes the effects of overvoltage and adjacent turbines due to single strike and multi strike to ground impedance changes when the surge arrester is deteriorated in a wind power farm.

직격뢰 침입시 배전계통 절연설계 (Insulation Design of Distribution Systems in Case of the Stroke of Direct Lightning Surge)

  • 정채균;김상국;이종범;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권4호
    • /
    • pp.238-247
    • /
    • 2004
  • This paper describes the insulation coordination scheme of line in distribution system when the direct lightning surge strikes. The BIL that is applied to distribution system is not properly considered the performance and operation of arresters. Because of that, the high BIL is being used at partial system. This paper variously analyses the lightning overvoltage of line and equipment with earth of overhead grounding wire and installation types of arrester. From these result. authors examine the rationality of BIL.

EMTP/ATPDraw를 이용한 가스절연송전선로(GIL)의 과전압 분석 (An Analysis on the Overvoltage in Gas Insulated Transmission Lines with EMTP/ATPDraw)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.999-1004
    • /
    • 2011
  • Nowadays, it is becoming difficult to secure a transmission line route when a new transmission line is constructed due to social environment and resident complaints. As existing urban areas are expanded and new cities are constructed, the necessity of high-capacity underground power transmission has been increasing because of load concentration in downtown areas. In North America, Europe and Japan, the research has been carried out for 2nd generation gas insulated transmission lines(GIL) which is more environmentally friendly and economical compared to previous GILs. The new GILs have been applied to real power systems from early 2000s. In South Korea, GIL is being considered as a possible solution for replacing 345kV high-capacity overhead transmission lines with underground transmission ones, so KEPCO is planning to develop and apply a new 362kV rated GIL underground transmission lines instead of overhead transmission lines. In this paper, the overvoltage generated at the combined transmission line adapting GIL was reviewed using EMTP.

Introduction of Insulation Coordination for UHV AC Systems

  • Shim, Eungbo;Zaima, Eiichi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1293-1297
    • /
    • 2015
  • This paper introduces the insulation coordination study results for UHV AC systems which was performed by CIGRE working group. The study results will be discussed within IEC technical committee in order to amend the IEC Insulation Coordination 60071-1 Ed. 8 2010 and 60071-2 Ed. 3, 1996. This paper includes the insulation coordination of transformer, gas insulated switchgear, metal oxide arresters and clearances of transmission towers. This article also illustrates the overvoltage specific to UHV systems such as TOV(temporary overvoltage), switching overvoltage, lightning overvoltage and VFTO(very fast transient overvoltage).