• Title/Summary/Keyword: Lighting load

Search Result 121, Processing Time 0.028 seconds

Energy Performance Assessment Study of Prismatic Solar Hybrid Collector System (Prismatic Solar Hybrid Collector 시스템의 에너지 성능 평가에 관한 연구)

  • Park, J.U.;Kim, K.S.;Lee, E.J.;Chung, M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2003
  • PSHC(Prismatic Solar Hybrid Collector) is a passive solar system composed of prismatic acrly glazing, glazing and ventilating fan. This PSHC system is applied to effectively reduce heating ventilation load as well as lighting load. But so far no method appraising thermal performance of this PSHC system has been developed yet. To assess thermal performance of the PSHC system, a prototype PSHC experimental facility and TRNSYS subroutine type-205 model have been developed in Korea Institute of Energy Research (KIER). The results indicated that l)TRNSYS empirical model of PSHC has been properly modeled with actual performance data, 2)a more reliable source of weather data such as NASA and KIER weather station have been also obtained, and therefore, 3)the annual energy performance of PSHC could be assessed based on this proposed TRNSYS model.

A Study on the Operator Performance According to the Drastic Change of Illumination Level and Lighting Environment of Control Room in Nuclear Power Plants

  • Shin, Kwang Hyeon;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objective: This study describes the change of operator performance in drastic change of illumination level, and proposes an alternative method to cope with it. Background: The control standard of illumination for nuclear power plants(NPPs) is based on the set of limit criteria for maintaining a specific illumination level. However, there is a possibility to cause human errors according to the psychological and physiological influences to operators in the situation of drastic change of illumination such as SBO(Station Black Out), so a basic study is necessary to review the current approach. Method: We assessed the visual fatigue, subjective work load and task performance according to the three illumination situations(Normal Illumination, Emergency Illumination, and Drastic Change of Illumination). Result: Research finding shows that there are not significant differences in task performance between normal illumination (1,000lx level) and emergency illumination (100lx level), only if beyond the dark adaptation limit. However, subjective work load on mental demand and visual fatigue show a potential challenge to visual performance in drastic change of illumination. Conclusion/Application: Several trials can complement this challenge in NPPs by applying 3-way communication, enhancing readability of procedures, and managing the visual factors affecting the operators' performance through a Visual Environment Management Program including visual health aspects, etc.

DSM Resources Evaluation and Customer Behavior Analysis (DSM 자원평가 및 소비자 행태 분석)

  • Ahn, Nam-Seong;Park, Min-Hyuk;Rhu, Jae-Gook
    • Korean System Dynamics Review
    • /
    • v.5 no.1
    • /
    • pp.49-71
    • /
    • 2004
  • Demand-side Management can be defined as'any utility activity aimed at modifying customers' use of energy to produce desired changes in the utility's load shape'. Customers benefit by being able to control energy costs and improve quality of life and become more productive. Utilities benefit from DSM's value as a resource that enhances asset utilization and reduces both fuel costs and environmental emissions. The scope of DSM includes load management through rate schedules and conservation by improving energy effciency and using electricity consumption effectively. This paper study the DSM resource evaluation and customer behavior analysis todesign the DSM Program plan in response to customer needs. We develop basic system dynamics model to analysis the customer behavior based on a survey research. The DSM Program participants in the Hi- efficiency Inverter, Electric motor and efficient lighting applicancies operating by Conservation program 2002 become the survey objects. DSM resource evaluation evaluate firstt the distribution potentialities of each machine and then forecast the degree of diffusion. We apply the system dynamic approach to simulate the dynamic DSM market situation at the domestic beginning. This model will give the energy Planner the opportunity to create different scenarios for DSM program planning. Also it will lead to increased understanding of the dynamic DSM market

  • PDF

Evaluation of Indoor Thermal Environment according to Type and Color of Blinds Installed in the Classroom (교실에 설치된 블라인드의 유형과 색상에 따른 실내 온열환경 평가)

  • Kwon, Daehyeok;Lee, Jae-Ro;Oh, Juseok;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.3
    • /
    • pp.224-232
    • /
    • 2017
  • Building energy saving have been put effort in a long time since buildings consume about 40.6% of total energy use, where heating, cooling and electrical lighting requirement results in energy consumption of building significantly. The window is an important part of building envelope, it usually brings a certain heat load from solar radiation while it allows light passing through, and properly leads to overheating in summer, hence the cooling load increase sand cause of thermal uncomfortable factor. The purpose of this study was to evaluate internal shade performance according to color and materials. There is growing interest in improving the sense of comfort among students who spend most of their time in the classroom. The study examined thermal environment and light environmental performance according to the color and materials of internal blinds to the school classroom. The results of this study were as follows; Among wooden blinds, aluminium blinds, and polyester blinds, the aluminium blinds were most excellent. In addition, among white blinds, light brown blinds, dark brown blinds, the light brown were most excellent.

The design of adaptive Controller for the Voltage Bus Conditioner for the improvement of the Power Quality in the DC Power Distribution System (DC 배전시스템의 품질향상을 위한 VBC 적응제어)

  • Woo, Hyun-Min;Lee, Byung-Hun;Chang, Han-Sol;La, Jae-Du;Kim, Young-Seok
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2348-2356
    • /
    • 2011
  • In recent years, many researches for DC power distributed system (PDS) are being preformed and the importance of the DC PDS is more and more emphasized. Furthermore, in the railway system, the DC PDS is used in subway station lighting, facilities, etc. In the DC PDS, DC bus voltage instability may be occurred by the operation of multiple parallel loads such as pulsed power load, motor drive system, and constant power loads. Thus, good quality and high reliability for electric power are required and voltage bus conditioner (VBC) may be used the DC PDS. The VBC is a DC/DC converter for mitigation of the bus transients. In this paper, adaptive controller is designed. The simulation results by PSIM are presented for validating the proposed control algorithm.

  • PDF

Analysis of Series Arc-Fault Signals Using Wavelet Transform (웨이블렛 변환을 이용한 직렬 아크고장 신호 분석)

  • Bang, Sun-Bae;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.494-500
    • /
    • 2008
  • This paper presents the analyzed result of the series arc fault current by using the discrete wavelet transform. The series arcing is caused by a loose connection in series with the load circuit. The series arc current is limited to a moderate value by the resistance of the device connected to the circuit, such as an appliance or a lighting system. The amount of energy in the sparks from the series arcing is less than in the case of parallel arcing but only a few amps are enough to be a fire hazard. Therefore, it is hard to detect the distinctive difference between a normal current and a intermittent arc current. This paper, presents the variation of the ratio of peak values and RMS values of the series arc fault current, and proposes the novel series arc fault detecting method by using the discrete wavelet transform. Loads such as a CFL lamp, a vacuum cleaner, a personal computer, and a television, which has the very similar normal current with the arc current, were selected to confirm the novel method.

Techniques of Management and Energy saving by using power installation (전력사용설비의 에너지 절감방안 및 관리를 위한 진단기법)

  • Chung, Choon-Byeong;Jeon, Kee-Young;Hahm, Nyun-Gun;Kim, Dae-Gyun;Lee, Sang-Chip;Oh, Bong-Hwan;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.329-333
    • /
    • 2004
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

A Study on Energy saving for refrigeration warehouse (냉동냉장창고에 대한 에너지 절약에 대한 연구)

  • Chung, Choon-Byeong;Kim, Dae-Gyun;Kim, Ik-Hwan;Lee, Sang-Chip;Hahm, Nyun-Gun;Jeon, Kee-Young;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.270-274
    • /
    • 2005
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

Power conversion control for zero emission buildings (탄소제로 빌딩을 위한 전력변환 제어)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.504-505
    • /
    • 2011
  • Decreasing actual greenhouse gas will be difficult if it is not solved addressed in architectural fields. Zero emission building or zero energy building, maximize the efficiency of energy, which means the building can operate by their own renewable energy facility without any other supplying. To be a zero emission building, a building needs realization of high efficiency low energy consumption, construction of building its own energy production facilities and lastly a power grid connection. According to increasing of DC load about TV, LED lighting, computer, IT in building for living and business, it is expected the save of energy when the system of AC power distribution change into the system of DC power distribution. Renewable energy exists a big different rate produced by outside environment. When electrical power overproduce, it can supply for system. Otherwise, if electrical power produce less, it can receive supply from system. Send and receive power can lead to zero to annual standard. This paper shows the simulation about efficient control of power conversion which is related to DC power distribution of architecture and DC output of renewable energy by using L-type converter.

  • PDF

A Study on Refrigeration warehouse operation for Energy saving technique (에너지 절감 기법을 적용한 냉동 냉장 창고 운영에 관한 연구)

  • Kim, Dae-Gyun;Kwon, Jung-Dong;Hahm, Nyun-Gun;Lee, Sang-Chip;Kim, Ik-Hwan;Lee, Seung-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.182-184
    • /
    • 2005
  • The human beings have Increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, intelligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF