• Title/Summary/Keyword: Lighting load

Search Result 121, Processing Time 0.027 seconds

Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication (전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

Comparison of the Energy Load according to the Balcony Types and Blind Installation (발코니 유형 및 블라인드 설치 유무에 따른 에너지 부하량 비교)

  • Lee, Jun-Gi;Lee, Gab-Taek;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.19 no.3
    • /
    • pp.63-68
    • /
    • 2015
  • We reviewed annual energy consumption for lighting, cooling and heating in relation to different types of office buildings and locations of window shading devices. Modeling of non-extensible and extensible offices was conducted using the Design Builder program, and simulations were conducted with window shading devices installed in different location.

Inverter Systems of Constant Current Regulate by Using Advanced Measurement and Switching Techniques (개선된 계측 및 스위칭 기법을 이용한 정전류조정 인버터 시스템)

  • Shon, Jin-Geun;Seo, Il-Dong;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.173-178
    • /
    • 2007
  • As development of industry is accelerated, most electricity load system requires power supply that could be high precision and effective control. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting & beaconing of aerodromes and electric heating system. Therefore, in this paper proposed a inverter systems of constant current regulate that using improved measurement and switching techniques. Proposed measure techniques that used moving average method of instantaneous r.m.s. for measuring current sensing improved response and precision. Also, in this paper proposed improved high effectiveness switching techniques that get high efficiency of inverter by the double-carrier modulation. Results of an experiment proved effect of proposed system.

Inverter Design and Control for Driving Electro-Luminescence Sheet (EL 시트 구동을 위한 인버터의 설계 및 제어)

  • Lee, Seung-Yo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.355-364
    • /
    • 2009
  • Electro-Luminescence (EL) sheets have been widely used in lighting displays, mainly used as advertisement panels. To drive the ELs in optimal conditions, it is required to understand the load profile of the EL. Hence, in this paper, a modeling for an EL sheet was performed to analyze the load characteristics of the EL. Based on the extracted model of the EL, a topology for inverter system was chosen and the optimal design parameters were obtained. The validity of the designed EL driver system was verified through computer simulations and experiments.

Recommended Practice for Lighting Load Density by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Subway Stations (회귀분석이론을 이용한 지하철 역사의 조명부하밀도 분석)

  • Jung, Hyeon-Ki;Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.254-259
    • /
    • 2006
  • It is increased electrical energy consumption with the development of intelligence society in the subway station and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design load density in subway stations, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 34 subway stations and 10 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, maximum and thus it was carried linear and nonlinear regression analysis.

  • PDF

A Low Cost Multiple Current-Voltage Concurrent Control for Smart Lighting Applications (저가형 스마트 LED 조명 구동을 위한 다수의 전류-전압 동시 제어 방법)

  • kim, Tae-hoon;Lee, Sang-hoon;yang, Joon-hyun;Im, Chang-soon;Hyun, Dong-seok;Kim, Rae-young
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.179-180
    • /
    • 2011
  • This paper focuses on the Current-Voltage concurrent control method devoted to the multiple LED (light-emitting diode) string driver. Isolated DC to DC converter with cascaded chopping switch is proposed for smart lighting system such as light with sensor or back light unit of display, which need to control the current of parallel connected multiple LED stings and regulate DC voltage for micro controller for brightness control. The proposed circuit regulates the current of parallel connected multiple LED strings and additional DC voltage output simultaneously. To verify the performance, experimental results are presented based on the prototype board. 5V, 1A voltage mode electric load and two LED strings with different forward voltages are used for output loads. 23W output power is achieved and measured efficiency is in the range of 85%-87%

  • PDF

A Study on the Effective M&V Method for the Lighting Control System (조명제어시스템을 위한 효율적인 계측 및 검증(M&V) 기법 연구)

  • Kim, Jeong-Uk;Boo, Chang-Jin;Kim, Jeong-Hyuk;Oh, Seong-Bo;Kim, Ho-Chan
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.216-223
    • /
    • 2011
  • This paper presents an effective energy saving algorithm for lighting control systems using M&V method in various buildings and factories. It is important to aggregate a various demand side resource which is controllable at the peak power time to reduce the energy cost. Previous demand side algorithm appropriate for building is based on peak power. In this paper, we develop the new energy saving algorithm using M&V method to reduce the quantity of power consumption. The simulation results show that the proposed method is very effective.

A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy (냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.

Implementation of Integration Dimming Switch for Home Network Using Z-Wave Mesh Network (Z-Wave Mesh Network 방식을 이용한 홈네트워크용 통합 디밍스위치의 구현)

  • Hwang, Gi-Hyun;Sul, Jae-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.5
    • /
    • pp.1198-1206
    • /
    • 2011
  • In this paper, we proposed a home network integrated dimmer switch using Z-wave Mesh Network. The dimmer switch come with wired and wireless network-based intelligent lighting switch that can be installed in a apartments with home network technologies. This switch is ease to install and operate. Furthermore, it provide power saving through efficient control of light using motion detect sensor and light intensity sensor. In order to evaluate the performance of our developed home network integrated dimmer switch, we performed a load performance test and from our result, it showed excellent performance in terms of lighting control and communication speed.

A Case Study on the Acclimatization's Housing for Environmental Load Reduction (환경부하 저감을 위한 기후순응주거 사례연구)

  • Cho, Sung-Woo;Oh, Se-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.69-79
    • /
    • 2013
  • The concept of sustainable development to preserve natural environment through economy in resources and energy is gradually distinguished since environmental problems as a series of air pollution and global warming take place now. Building occupies more than 1/3 of energy consumption in the whole world. Energy consumption of buildings caused a quick increase in the amount of energy use by air conditioning, which has a lot of effects on exhaustion of fossil energy as well as an increase in environmental load. Therefore, this research intends to suggest characteristics and direction for the designing of acclimatization's housing through the case study on acclimatization's housing. Acclimatization's housing is designed to reduce building load from the designing stage unlike green home or low-energy apartment. Also, factors which are commonly applied to acclimatization's housing are applied complexly by design strategic factors of Heating, Cooling and Lighting. The applied design factors make effects mutually and complexly. In addition, design strategy showed different priority by designing direction.