• Title/Summary/Keyword: Lighting design

Search Result 1,055, Processing Time 0.023 seconds

A Study on the Improvement Direction through the Present Status of Nursing Home - Focus on the Nursing Home in Chungcheongbuk-do - (노인요양시설의 건축현황 및 개선방향에 관한 연구 - 충청북도 노인요양시설을 중심으로 -)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.242-250
    • /
    • 2010
  • Recently, the long-term care insurance for the elderly was carried out according to the elderly is increased rapidly and the formation of sympathy that a nation and society try commonly to share health and welfare promotion of the elderly. The purpose of this study is to analyze the present status of nursing home after that the long-term care insurance is enforced in chungcheongbuk-do and to utilize as basic data. The study limited its survey to those facilities that refer to the Ministry of Health and Welfare data, that had the capacity of more than 50 people. The result are as followings. Firstly, most of the nursing home were located on the outskirts of the city. But it must be constructed in the city center if the recent deinstitutionalization trend is reflected. Secondly, notwithstanding the provisions of the Elderly Welfare Law, if the Livability and amenity are considered, the plan of a single or a twin room is needed. The ondol(溫突) system bedroom for the safety of the elderly had to be planned and for the color planning of a bedroom, a heating, the furniture, the form of a door, corridors, etc. should be partly improved. The fastener in which it is appropriate for the main exit, a stair, an elevator, the lighting device, and etc. is needed and the installation of a wandering path for the dementia patient and etc. is required. Thirdly, most of the dining room arranged on the first floor but it is not nearly used and it used for employee or the other use. Therefore, we have to consider the system in which it can deliver the meal to a bedroom. If the smell of the elderly and etc. is considered, the sufficient height of the floor should be reflected for the ventilation equipment. Lastly, The improvement of the existing law are required.

Wireless LED Streetlight Platform with Weather Monitoring and Color Temperature Control System (기상 모니터링과 색 온도 제어 시스템을 지원하는 무선 LED 가로등 플랫폼 설계 및 구현)

  • Daely, Philip Tobianto;Bayu, Satrya Gandeva;Kim, Jin Woo;Jang, Yunseong;Kim, Dong-Pyo;Shin, Soo Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.5
    • /
    • pp.1038-1046
    • /
    • 2017
  • In this paper, we propose the design of LED Streetlight Platform with capabilities of weather monitoring and color temperature control. Several previous works are focused on the energy efficiency or data management of streetlight system, but no work has been done on the lighting performance, especially when natural phenomenon such as fog or haze appears on the street and obstructs the visibility of drivers and pedestrians. To solve such issue, we propose the use of two LED lamps with different correlated color temperature, which will be activated interchangeably according to the condition on the street. We also present the design of communication scheme between each devices in the system. Moreover, our experimental results show the LED Streetlight Platform can perform well and the data can be displayed properly at the website.

Investigation of Natural Convective Heat Flow Characteristics of Heat Sink (히트싱크의 자연대류 열유동 특성 분석)

  • Jung, Tae Sung;Kang, Hwan Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • To ensure proper functioning of electrical and mechanical systems, cooling devices are of great importance. A heat sink is the most common cooling device used in many industries such as the semiconductor, electronic instrument, LED lighting, and automotive industries. To design an optimal heat sink, the required surface area for heat radiation should be calculated based on an accurate expectation of the heat flow rate in the target environment. In this study, the convective heat flow characteristics were numerically investigated for a vertically installed typical heat sink and a horizontally installed one in free convection using ANSYS CFX. Comparative experiments were carried out to reveal the quantitative effect of the installation direction on the cooling performance. Moreover, the result was analyzed using the dimensionless correlation with the Nusselt number and Rayleigh number and compared with well-known theories. Finally, it was observed that the cooling performance of the vertically installed heat sink is approximately 10~15% better than that of the one in natural convection.

Theoretical Design for the Production of Quinoa (Chenopodium quinoa Willd.) in a Closed Plant Factory

  • Bae, Jong Hyang;Austin, Jirapa;Jeon, Yoon-A;Cha, Mi-Kyung;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.840-844
    • /
    • 2016
  • Quinoa (Chenopodium quinoa Willd.) is a grain crop with high nutritional value. The leaves and sprouts of quinoa can also be consumed either raw or cooked, providing considerably nutritional value as well as high antioxidant and anticancer activities. This study was carried out to obtain basic data to assist in the practical design of a plant factory with artificial lighting for the cultivation of quinoa as a leafy vegetable. We estimated the energy content of the quinoa and the electrical energy required to produce this crop. The yield was 1,000 plants per day, with a planting density and light intensity of $0.015m^2$ ($15{\times}10cm$) and $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. The total number of plants, cultivation area, and electricity consumption were estimated to be 25,000, $375m^2$, and $93,750{\mu}mol{\cdot}s^{-1}$, respectively. White fluorescent lamps were used at a power of 20.4 kW from 1,857 fluorescent lamps (FL, 55 W), and the cost for electricity was approximately 1,820 dollars (exchange rate of $1 = 1,200 won) per month. For a daily harvest of 1,000 plants per day in a closed plant factory, the estimated light installation cost, total installation cost, and total production cost would be 15,473, 46,421, and 55,704 dollars, respectively. The calculated production cost per plant, including labor costs, would be 27 cents for the 25-day cultivation period, with a marketable ratio of 80%. Considering the annual total expenses, income, and depreciation costs, the selling price per plant was estimated to be approximately 56 cents.

A Study on the Comparative Analysis and Improvement of Indoor Environmental Factor in Green Building Rating Systems (국내외 친환경건축물 인증제도 실내 환경 관련 부문 비교분석 및 개선안 연구)

  • Joh Hahn
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.21-28
    • /
    • 2006
  • To promote environmentally responsible architectural practice, many nations have established their own green building rating system. Among other criteria, recently the indoor environmental quality section has been paid great attention due to Sick Building Syndrome, as this believed to caused by polluted indoor environment. In this context, indoor environmental quality is one of very important sections of each green building rating system and closely related to the very happiness of building users. The goal of this research is to compare and analyze the indoor environmental sections of three green building rating systems, GBCC, LEED v2.1, and BREEAM Office 2005, and find a direction for the improvement of GBCC. First, the three rating systems are analyzed in general to compare the importance of indoor environmental factors in each system. Second, the indoor environmental factors are reclassified within related sub-categories for the comparable analysis. Finally, based upon the comparable analysis, directions for the improvement of GBCC are as follows: 1. GBCC's h4r Environment Section needs to clarify its VOCs criteria based upon types of finish materials. 2. Sound Environment Section's noise control criteria needs to be revised based upon types of building usages and application method. 3. An indoor lighting related section needs to be included in GBCC, as even though light is the one of the most important factors in indoor environment, it has not been included in GBCC yet. 4. The sub-section of Confortable Indoor Environment Section related to the resting space and the universal accessibility are not in accord with the goal of green building rating system. These items need to be dealt within general building codes. 5. The rating evaluation structure and process need to be streamlined.

A Study on the Resident Evaluation for Bathroom Plan of Large-size Brand Apartment (대형 평형 브랜드 아파트의 욕실 평면에 대한 거주자 평가)

  • Shin, Kyung-Joo;Park, Jong-Hye
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.3
    • /
    • pp.11-19
    • /
    • 2009
  • This research grasped the change of bathroom type, the present status for the residents' bathrooms, the level of satisfaction and preference for the residents' bathrooms, along with the plane of large-size apartment. This research aims to contribute to making the bathroom space to be able to satisfy the residents' desires. A total of 115 samples, acquired via internet survey, were analyzed with the statistical computer program SPSS PC+ 15.0 with the bathroom plane analysis. The results of this research are as follows. 1) As the results of the most representative plane, were divided into total 4 bathroom types, public bathrooms were $3.9-5.29m^2$ couple bathrooms were over than $3.17-8.3m^2$ in the average bathroom area, and there were two in less than $199m^2$ and even three in more than $199m^2$ in the number of bathrooms. 2) Three bathrooms were preferred by the residents who have three bathrooms now and by the younger generation though two bathrooms were preferred by most residents in the bathroom number. Most of the public bathrooms and couple bathrooms were considered to be proper in the bathroom area. 3) The preferred types were different according to each brand in the preference of the bathroom form. This means that to present a new plane figure including various bathroom forms is recommended in planning the bathroom space hereafter, that the bathroom spaces are changing. 4) In the bathroom environment, to present the technical solution through the study for the natural lighting and the sound arresting is required. This research hopes that the results of this research will be able to be used as the basic data to provide the bathroom space equipped with a pleasant environment condition to the residents.

Conceptual Design for Lifetime Test System for LED Headlamps on Rolling Stock (철도차량용 LED전조등의 수명시험 장치 구축을 위한 개념설계)

  • Ohn, Jung-Ghun;Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.2
    • /
    • pp.111-116
    • /
    • 2015
  • LED luminaires as a lighting system have attracted much research attention due to their high efficiency and long lifetimes. However, disappointing outcomes have been noted in terms of performance levels and lifetimes as compared to desired system requirements in practice due to certain electrical and thermal characteristics of LEDs. LM-80 and TM-21 established by IESNA are the best known standards for lifetime test procedures and estimation techniques. However, they only handle LED light sources without guaranteeing the LED luminaire in a reliability test. They also operate for more than 6,000 hours and undergo various stresses, such as the operating current and temperature. Therefore, a lifetime standard for LED luminaires has not yet been established. This paper proposes a conceptual design of a lifetime test system for LED headlamps depending on the operating environment. Eventually, this method can assist with evaluations of the validity of lifetime standard tests of LED headlamps.

A Study on oblique spatial expansion through Henry Ciriani's 4 Logements Studio (앙리 시리아니의 4 Logements Studio를 통한 사선적 공간확장성에 대한 연구)

  • Jun, In-Mok
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.6
    • /
    • pp.227-235
    • /
    • 2017
  • The essence of architecture is space acquired as a result of architect's design act, but the object of the design is not the space and it is the physical elements to construct it. The masters of modern architecture have described the types of spaces that can be composed of these elements, but there is a difficulty in constructing the space because they does not mention how to construct it. From this point of view, if architecture is the techniques for human behavior and the art of building space, it is recognized that there is a need for concrete research on how to construct a space with ambiguous substance. Therefore, I conducted research on the extensibility of diagonal spaces through '4 Logements Studio' by Henri Ciriani, a representative architect of Neo Corbusian. The 'network for identity' method proposed by Ciriani was examined as a methode to realize spatial expansion and the furniture should be designed as an element of reading space and 3 optimal alternatives for 4 housing arrangements were obtained based on the Equivalence, Lighting, View, and Community life.

Safe Adaptive Headlight Controller with Symmetric Angle Sensor Compensator Using Steering-swivel Angle Lookup Table (조향각-회전각 룩업테이블을 이용한 대칭형 각도센서 보상기를 가지는 안전한 적응형 전조등 제어기의 설계)

  • Youn, Jiae;An, Joonghyun;Yin, Meng Di;Cho, Jeonghun;Park, Daejin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.112-121
    • /
    • 2016
  • AFLS (Adaptive front lighting system) is being applied to improve safety in driving automotive at night. Safe embedded system design for controlling head-lamps is required to improve noise robust ECU hardware and software simultaneously by considering safety requirement of hardware-dependent software under severe environmental noise. In this paper, we propose an adaptive headlight controller with a newly-designed symmetric angle sensor compensator, especially based on the proposed steering-swivel angle lookup table to determine whether the current controlling target is safe. The proposed system includes an additional backup hardware to compare the system status and provides safe swivel-angle management using a controlling algorithm based on the pre-defined lookup table (LUT), which is a symmetric mapping relationship between the requested steering angle and expected swivel angle target. The implemented system model shows that the proposed architecture effectively detects abnormal situations and restores safe status of controlling the light-angle in AFLS operations under severe noisy environment.

A Study on Pattern of Introducing the Nature into Interior & Exterior of Modern Architecture - Focusing on Water and Plant - (현대건축 내.외부에 나타나는 자연도입 유형에 관한 연구 - 물과 식물을 중심으로 -)

  • Kang, Hee;Hur, Yong-Seok;Hur, Bum-Pall
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.1
    • /
    • pp.46-54
    • /
    • 2010
  • Since the accomplishment of industrialization and mechanization, human and the nature have gone farther their own way. Human depending on technology have been increasingly expanding and developing their artificial space and as times go by in such a way, estrangement between the human and nature has resulted in dissatisfaction of human's instinctual desire and devastation of human's living. People, to deal with such challenge, begins taking a look at the nature. In introducing the nature into the modern architecture, a physical natural element is often directly taken into or the shape that could be inferred from the nature is taken. The study was intended to identify the characteristics of the pattern introducing the nature into the modern architecture, as mentioned in the former case, which is summarized as follows, Introduction of the nature contains a variety of functions in the space and it creates the new space by integrating the internal and external space which becomes boundaryless integrated space. The boundary in the building tends to be getting more ambiguous, while the space accommodating the nature serves the interface, playing a role of intermediator for both the internal and external space. It functions the open public place that helps build the natural community among the users but taking the nature into the inner space, and it is used to attempt to change the interior of the building or for ventilation lighting or energy-saving purpose. The spatial meaning was found to have varied depending on pattern of the nature introduced. Such conclusions mentioned hereon is expected to help forecast and understand the forthcoming space accommodating the nature when reviewing the pattern of introducing the nature appeared In modern architecture.