• Title/Summary/Keyword: Lighting conditions

Search Result 510, Processing Time 0.025 seconds

A Study of High Efficiency Electrodeless lamp Properties (고효율 신광원 시스템의 특성에 관한 연구)

  • Kim, H.S.;Lee, S.H.;Shin, S.W.;Lim, J.M.;Huh, S.K.;Hwang, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1717-1720
    • /
    • 2002
  • Electrodeless discharge lamps have been objects of interest and research for several decades, mainly because of their potential for extremely long life, high lamp efficacies and smaller than standard fluorescent lamps size. A series of measurements and observations concerning variables has yielded optical and electrical characteristics for electrodeless discharge lamp like incandescent lamp and circular lamp feature. Last experiment were carried out to determine the lamp temperature at several surface points during operation. Light output levels in excess over 60,000 cd/$m^2$ have been measured in electrodeless discharge lamp for a general of conditions. At lamp surface temperatures have been measured over $80^{\circ}C$, and starting current have been measured over ${\sim}A$.

  • PDF

Study on the Thermal Behavior of Immersion Cooled LED Lighting Engines (담금 냉각되는 LED 조명엔진의 열특성에 대한 연구)

  • Kim, Kyoung Joon
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.87-92
    • /
    • 2014
  • This study is aimed at investigating the thermal behavior of immersion-cooled high power LED lighting engines. 3D CFD models have been generated for the numerical analysis. Five cases in terms of the configuration of LED chips have been explored for various passive cooling conditions of the lighting engine, i.e., the natural air convection with a lens, the natural air convection without a lens, the deionized water-immersion cooling condition with a lens. The numerical study reveals that the deionized water-immersion cooled lighting engine has nearly twice better thermal performance than the natural air convection cooled lighting engine containing a lens. The investigation has also demonstrated that the four chips configuration has the better thermal performance than the single chip configuration.

A Fundamental Study for Proper Application of Lighting Simulation Software (조명시뮬레이션 소프트웨어의 적합한 사용을 위한 기초적 연구)

  • Kim, Yu-Sin;Won, Seul-Ki;Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.10-19
    • /
    • 2007
  • Use of various lighting simulation software has been increased Lighting simulation software can be categorized into two types. One is for optical design while the other is for estimation and analysis of lighting design. Photopia 2.0 is typical software for optical design of a luminare and Lumen-micro 2000, Relux 2006, Lightscape 3.2 and AGI 32 are software for lighting design. Through using various lighting simulation software some different results can be found under the same conditions. Therefore, the purpose of this paper is to compare measured and simulated photometric data of different types of luminaires and to compare simulated values from Lumen-micro 2000, Relux 2006, Lightscape 3.2 and AGI 32 under the same conditions. In addition, the reasons for such differences are analyzed.

Effect of Agricultural Machine Lighting systems on Drivers Night Visibility (농기계의 등화장치가 운전자의 야간시인성에 미치는 영향)

  • Choi, Seung hyun;Lee, Sung yeol;Jang, Taek young;Do, Myung sik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.4
    • /
    • pp.25-35
    • /
    • 2017
  • This study aimed to analyze a driver's night visibility, according to the installation of a lighting system for driving an agricultural machine during the night time. For the night visibility analysis, a luminance measurement test on the lighting system and a gaze duration measurement test through eye movement measurement devices were carried out. In the luminance measurement test, the increase of luminance was confirmed as relative distance from an agricultural machine was closer and the conditions of the lighting equivalence are improved. Also the gaze duration measurement test, total gaze duration from an agricultural machine increased, as the conditions of the lighting equivalence are improved. In addition, it was identified that the difference in average gaze duration from an agricultural machine was statistically significant as the agricultural machine was driven in high speed. In conclusion, when the lighting system is installed on an agricultural machine, a driver's night visibility from the agricultural machine improves, which is expected to be enormously helpful to the prevention of agricultural machine accidents.

A Study of Integrated Evaluation of System Lighting and User Centered Guideline Development - Focused on the Lighting Design Method for Office Space - (시스템조명 통합평가 및 사용자 맞춤형 가이드라인 개발 연구 - 사무공간 설계방법을 중심으로 -)

  • Kim, Ju-Hyun;Ko, Jae-Kyu;Cho, Mee-Ryoung
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.78-86
    • /
    • 2014
  • Lighting in indoor space is being changed to system lighting converged with IT technology. Office space lighting with incandescent lamps and fluorescent lamps was completed through overall lighting plan by illumination in most cases, but convergence between LED lighting and IT technology enables the technology of responding to user requirements to be realized. Optical physical quantity suitable for humans and the lighting environment in accordance with user's sensibility, based on space function and user's behavior, would contribute to the improvement of service productivity, energy reduction, and enhancement of emotional satisfaction by providing user optimized lighting solution. Thus, user-customized system lighting guidelines to be applied with integration indicators of optics and sensibility are required. For the design elements required by users, environmental factors, product characteristics, optical characteristics, and sensibility factors are drawn from the design cases for office space and the survey, and the design check list and evaluation indicators are considered to reflect the requirements in the design and requirement indicators to give integrated satisfaction for optics and sensibility are developed. Purpose-centered design method from the user's viewpoint is applied to function-focused design through scenario, and it should be applied flexibly, as the new lightning design method solutions, to the concept design stage of space lighting design and device development. This paper, therefore, presents user-customized guidelines by pursuing the optics and sensibility evaluation and design method combining the requirement conditions and scenario, to be used for lighting content development and design.

Comparison Research between Lighting Based on luminance and Illuminance through Measuring Tunnel Lighting (터널조명 측정을 통한 조도와 휘도기반의 조명 비교 연구)

  • Lee, Mi-Ae;Han, Seung-Hun;Kim, Yeon-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.14-19
    • /
    • 2013
  • Tunnel lighting design and operation are both regulated based on luminance in and out of Korea these days. However, domestic tunnel lighting is operated by internal lighting depending on external brightness by using an illuminometer applying the conversion factor on luminance. The purpose of tunnel lighting is to alleviate the visual shock occurring from the rapid change from external brightness to internal brightness when entering a tunnel. However, when looking at the tunnels operated based on an illuminometer, it is not a system where the driver can measure the brightness within his or her viewing angle when entering the tunnel. It is general to install and operate the illuminometer on the roof of an administrative office near the tunnel; however, this method is not structured to connect with the internal lighting by checking the brightness of the viewing scope of the driver, thus is not structured to properly apply the viewing conditions of the driver. Rather, it should be in a method for extracting the luminance value within the viewing scope of the driver pursuant to tunnel lighting standards and in connection with internal lighting. This research seeks to find the difference between operations based on luminance and operations based on intensity of Illuminance in road tunnels through field measuring, and to suggest the necessity of operating based on luminance with the resulting value.

Accuracy Evaluation of the Three-Curve Method and the Zonal Cavity Method (3배광법과 구역공간법의 정확도 평가)

  • Sim, Sang-Man;Kim, Chang-Seop;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.53-59
    • /
    • 1995
  • The accurcy and the application limits of the Three-Curve Method(TCM) and Zonal Cavity Method(ZCM) are evaluated. Average illuminance values are calculated by TCM and ZCM for various lighting conditions using general Diffusing Luminaires and Direct Luminaires. These values are compared with the values from Monte-Carlo Simulation(MCS) for the same lighting conditions. Accuracy of MCS was proved by Moon's Analytical Method.

  • PDF

Subjective Evaluation on the Color Temperatures of LED illumination in the Classroom (학교 교실 LED 조명의 색온도에 대한 주관적 평가)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.30-41
    • /
    • 2011
  • This study performs the subjective evaluations of LED illumination conditions according to three types of color temperatures (7,000[K], 5,000[K], 3,000[K]) after employing LED illumination system in the classroom, Since the objective of this study is to develop an artificial lighting conditions like day light comfortable to students in the classroom, the learning effect based on three types of LED illumination conditions are analyzed. Three factors (learning intention, learning environment, learning motivation) are extracted by ANOVA and there are preference differences of LED illumination conditions between learning intention and learning environment factors. Especially, preference differences of LED illumination conditions are existed about calculation, reading and fatigue reduction. The test results of this study can be applied to obtaining high achievement of learning based on the lighting conditions.

Effects of Current Modulation Conditions on the Chromaticity of Phosphor Converted (PC) White LEDs

  • Kim, Seungtaek;Kim, Jongseok;Kim, Hyungtae;Kim, Yong-Kweon
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.449-456
    • /
    • 2012
  • For two well-known modulation methods, stepwise current modulation (SCM) and pulse width modulation (PWM), the effects of driving current modulation conditions on chromaticity were experimentally investigated in a white LED lighting system. For the experimental implementation of both SCM and PWM, a white LED lighting was fabricated using phosphor converted (PC) white light emitting diodes (LEDs) and a driving circuit module was developed. By using them, the variations of illuminance, color coordinates, and spectrum were evaluated under various forward current conditions. Through the analysis in color coordinates, yellow shift in SCM and blue shift in PWM were observed on chromaticity diagrams with increasing average driving current. In addition, in order to analyze color deviation quantitatively, color distance before and after current increase, and the correlated color temperature (CCT) were calculated. As a result, for the white LED lighting in both modulation conditions, the maximum difference in the calculated CCT was obtained close to 1000 K. It means that careful consideration is required to be taken in the design of illumination systems to avoid serious problems such industrial accidents.

Remote monitoring of light environment using web-camera for protected chrysanthemum production (웹 카메라를 이용한 시설 내 국화생산 광 환경 원격 모니터링)

  • Chung, Sun-Ok;Kim, Yong-Joo;Lee, Kyu-Ho;Sung, Nam-Seok;Lee, Cheol-Hwi;Noh, Hyun-Kwon
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.4
    • /
    • pp.447-453
    • /
    • 2015
  • Increase of national family income improved demand of high-quality and year-round horticultural products including chrysanthemum. To meet these demand, farmers have introduced protected facilities, such as greenhouses, of which environmental conditions could be monitored and controlled. Environment management up to three weeks after transplanting is critical for chrysanthemum quality. Artificial lighting and light-blocking screen are especially important for long-day (day period > 13 hours) and short-day (night period > 13 hours) treatments. In this study, a web-camera was installed, and the image was obtained and transmitted to mobile phones to monitor the status of 3-wavelength(RGB) lighting environments. RGB pixel values were used to determine malfunctioning of the lighting lamps, and leaking out and incoming illumination status during short-day and long-day treatment periods. Normal lighting lamps provided RGB pixel values of 240~255. During long-day treatment period, G pixel values were useful to detect abnormal lighting conditions (e.g., leaking). During short-day treatment period, R pixel values were useful to determine incoming light (e.g., sun-light). Results of this study would provide useful information for remote monitoring of light conditions for protected chrysanthemum production under artificial lights.