• 제목/요약/키워드: Lighting Maintenance

Search Result 120, Processing Time 0.025 seconds

An Analysis of Important Design Factors for Rising of Qualitative Level and Revitalization in the Public Open Spaces (공개공지의 질적 수준 향상 및 활성화를 위한 중요 설계요소 분석 - 설계자와 이용자의 인식차이를 중심으로 -)

  • Chae, Du-Byeong;Lee, Joo-Hyung;Song, Hee-Yeal
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.95-104
    • /
    • 2010
  • The purpose of this study was to found that the important design reform points for improvement of the public open space quality. For this purpose, surveyed the users of the public open space and the experts working for the public open space planning for the design elements of the public open spaces in terms of importance and satisfaction. The scope of the study was limited to Mapo-gu, Seoul and the buildings constructed since 1992 were sampled. the data collected were subject to Importance-Performance Analysis. As a result, 'waste boxes, vending machines and other amenities', 'characteristic floor and pedestrian environment', 'designs and their layout in harmony with the surrounding and landscape facilities', 'facilities checking and patrol for safety' and 'entire area of the public open space'. Based on the above findings, the following reform measures are put forwards for improvement of the public open space quality; First, the public open spaces should be equipped with sufficient amenities. Second, it is necessary to check the facilities regularly, while enhancing the safety through patrols. Third, it is essential to reflect user's needs in public open space planning, while applying the important design elements to the public facilities. Fourth, in order to create a comfortable pedestrian environment within the public open space, it is deemed necessary to divide the space into the passages for passers-by and the recesses for uses. Fifth, it is necessary to amend the Building Code to the effects that the radio of the landscaped area to the entire area can be readjusted together with the night lighting facilities. Sixth, it is desirable to give the weights to the important design elements for the public open spaces, so that the quality public open spaces can benefit from the incentives. In addition, regular maintenance and management should be ensured by policies.

A Basic Study on the Checklists for Crime Risk Assessment in Physical Environment of the Pedestrian Passage at Residential Area (주거지역 소규모 보행로의 물리적 환경을 대상으로 한 범죄 위험도 평가 체크리스트에 관한 기초 연구)

  • Lee, You-Mi;Park, Hyeon-Ho;Kang, Boo-Seong;Sung, Gi-Ho;Lim, Dong-Hyun
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.47-55
    • /
    • 2016
  • Purpose: This study was aimed at providing the basic checklist as a means to assess the crime risk in physical environment of the pedestrian passage at residential area. Method: For this purpose, the preliminary checklists were selected according to the review of the precedent studies of checklists in exterior pedestrian passage. The usefulness and the importance of the preliminary checklists were analyzed through the seven expert group meetings, the 87 questionnaires survey of the crime experts & the architectural/urban experts, preliminary assessment and field survey. Results: The assessment categories of checklists were sorted into six types, i.e. spatial structure & function, lighting, landscaping, security facilities, other facilities and cleaning & maintenance. The 49 checklists were proposed according to the assessment categories. The final checklists were divided key checklists and general checklists based on the results of experts' weighting of each list item. There were significant differences between crime experts' weighting and architectural/urban experts' weighting in several checklists, i.e. dividing between pavements and streets, the brightness of light, white light.

Development of the Sentiment Indicators of Housing Welfare (주거복지지표 개발에 관한 연구 II - 수요자 측면의 주거복지체감지표와 지수를 중심으로 -)

  • Jee, Eun-Young;Eun, Nan-Soon;Hong, Hyung-Ock
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.85-92
    • /
    • 2008
  • The aim of this research is to develop the sentiment indicators of housing welfare for evaluating housing welfare policies conducted by the Korean government. The methods of this research are used by analysis of related documents, FGI (Focus Group Interview), and survey. The survey was made by experts and consumers. To analyze the survey, this research also uses confirmatory factor analysis by SPSS (Statistical Package for the Social Science) program, AHP (Analytical Hierarchy Process) by Expert Choice program, frequency, average, percentages, Factor analysis etc. As a result of this research, selected housing welfare indicators are settled as follows: In the housing welfare aspect, 11 indicators in the department of 'Housing Satisfaction' and 11 indicators in the department of 'Community Satisfaction' (22 in total) are suggested. The indicators are 1) Water Supply and Distribution Equipment 2) Heating equipment 3) the size of the exclusive residential area 4) the number of rooms 5) Ventilation and Lighting 6) Sound Insulation (Indoor Noise) 7) Air Pollution/Odor 8) House Deposit 9) Rent Paid 10) Maintenance (Dwelling) Cost 11) The length of Occupation 12) Proximity to Welfare Facilities 13) Educational Environment 14) Convenience of Facilities (shops, hospitals etc.) 15) Convenience of Transportation and Commuting 16) Distance from Workplace 17) Landscape and Green Space (Tree, Flowers, Grass etc.) 18) Vandalism (Destruction Behavior, graffiti etc.) 19) Privacy 20) Noise in Public Places (Drinking, Loudly Talking etc.) 21) Safety from Crime 22) Safety from a Disaster. As of 2007, the housing welfare sentiment index is measured by the survey of 1,000 inhabitants in the public housing, which shows 3.51.

An Analysis of Driver Perception of Nighttime Visibility Using Fuzzy Set Theory (퍼지집합이론을 이용한 야간 도로 시인성 평가)

  • LEE, Dong Min;Youn, Chun Joo;KIM, Young Beom
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.57-66
    • /
    • 2015
  • PURPOSES: Nighttime driving is very different from daytime driving because drivers must obtain nighttime sight-distances based on road lights and headlights. Unfortunately, nighttime driving conditions in Korea are far from ideal due to poor lighting and an insufficient number of road lights and inadequate operation and maintenance of delineators. This study is conducted to develop new standards for nighttime road visibility based on experiments of driver perception for nighttime visibility conditions. METHODS : In the study, perception level and satisfaction of nighttime visibility were investigated. A total of 60 drivers participated, including 34 older drivers and 31 young drivers. To evaluate driver perceptions of nighttime road visibility, fuzzy set theory was used because the conventional analysis methods for driver perception are limited in effectiveness for considering the characteristics of perception which are subjective and vague, and are generally expressed in terms of linguistic terminologies rather than numerical parameters. RESULTS : This study found that levels of nighttime visibility, as perceived by drivers, are remarkably similar to their satisfactions in different nighttime driving conditions with a log-function relationship. Older drivers evaluated unambiguously degree of nighttime visibility but evaluations by young drivers regarding it were unclear. CONCLUSIONS : A minimum value of brightness on roads was established as YUX 30, based on final analyzed results. In other words, road lights should be installed and operated to obtain more than YUX 30 brightness for the safety and comfort of nighttime driving.

A study on the accommodation of common LED to shipboard (육상용 LED 램프의 선박 적응력에 관한 연구)

  • Jeong, Ji-Hyun;Park, Hwan-Chul;Kim, Yong-Joo;Seo, Sang-Do;Han, Seung-Jae;Kim, Min-Sok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

Analysis of Sunshine Amount for Education Environment according to Installation of Apartment Structures (아파트 구조물 설치에 따른 교육환경 일조량 분석)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • Due to recent urban maintenance project for the aged towns, the reconstruction of apartments into super-high-rise and high-rise apartment structures has been approved for concentrated use of land, and accordingly the infringement on sunshine for nearby residential area is rising as a social issue. Especially the educational environment conditions according to infringement on sunshine in educational facilities are posing many problems. Accordingly in this study, for such sunshine analysis of educational environment, Auto $CAD^{(R)}$ software has been used to construct the 3D model for the educational facility structures. And with the simulation technique, the windows and the schoolyard of the education facility were set to be the lighting standard surface to take measurements for the sunshine environment of the educational facilities by the minute from 8:00AM until 4:00PM for the sunshine amount by true solar time according to the movement of the sun. Also, the sunshine environment of the education facility according to the damage before/after new construction of apartments was charted, and through comparison with the video produced by sun shadow projection method, the sunshine amount of the educational environment could be verified. In future, it is expected to be efficiently used in the sunshine analysis of education environment utilizing such simulation techniques.

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

The Protection methods of Telecommunication Network from Electrical Transient Phenomena (전기적 과도현상으로부터 통신망의 보호대책)

  • Choi, Man-Ho;Kim, Hyun-Duk;Kim, Byung-Cheul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.693-696
    • /
    • 2005
  • Parallel and cross of the electrical power and telecommunication network is become accelerated, because telecommunication equipments are constructed according to road for efficient maintenance of domestic telecommunication network. The electrical power network can generate an electrostatic induction, and is itself transmission medium from electrical transient phenomenon such as lighting. So, transient phenomenon of lightning surge is induced to telecommunication network, and then it is damaged by connecting between electrical ground of electrical power network and telecommunication network. In this study, we found that cut-off of return path current by separate distance between electrical ground of electrical power network and telecommunication network, and cut-off of electrostatic induction voltage by grounding unused leads of both terminals of the electrical and telecommunication network have good effect as the protection methods of telecommunications network from electrical transient phenomena.

  • PDF

Design of the 140W level-small sized LED Power Control Circuit (140W 급-저면적 LED 전원 제어 회로 설계)

  • An, Ho-Myoung;Lee, Juseong;Kim, Byungcheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.586-592
    • /
    • 2018
  • In this paper, HIC with various functions is proposed for the design 140W LED power control circuit. The proposed HIC integrates constant voltage/constant current circuit, short circuit protection circuit, internal constant voltage circuit, and dimmer circuit, thereby reducing the horizontal length of the PCB by 16% comparing with the conventional system. Through various experiments, we verified the performance of each block implemented inside of HIC with numerical results. (Constant voltage variation ratio: 2.9%, dimmer circuit duty variation within 5%, stable short protection at 720 mA) Since the PCB area can be significantly reduced by applying the proposed HIC. It is possible to reduce the PCB manufacturing time which takes up most of the manufacturing time, however, It is expected that the faulted power module can be replaced without replacing the whole PCB, so that maintenance / repair can be made easier.

Analysis and Improvement of False Alarm Phenomenon of Emergency Hydraulic Warning Light by Shielded RF Radiation Signal (RF 방사 신호 차폐를 통한 비상 유압경고등의 비정상 점등 현상의 원인분석 및 개선)

  • Jung-Hyuk Kwon;Gyeong-Nam Kim;Byeong-Kwon Jeon;Wang-Sang Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.68-78
    • /
    • 2023
  • In this paper, improvement measures were studied for false alarm (abnormal lighting) of emergency hydraulic warning light due to RF radiation signals in aircraft. When the warning lamp of the emergency hydraulic system is lit during flight due to electromagnetic interference caused by RF radiation signals, it affects flight mission and safety which can result in efficiency degradation and maintenance of flight mission. For false alarm of emergency hydraulic warning light, root cause analysis and troubleshooting were carried out. By shielding a composite strip under fuselage of the aircraft located in the path of the RF radiation signal, the RF radiation signal flowing into the emergency hydraulic indicator was blocked. Results of applying the improvement method through ground and flight monitoring were also described.