• Title/Summary/Keyword: Lighting Energy

Search Result 673, Processing Time 0.044 seconds

The Impact of Population Aging on Energy Use and Carbon Emissions in Korea (인구 고령화가 에너지 사용과 탄소 배출에 미치는 영향)

  • Kim, Dong Koo;Park, Sunyoung
    • Journal of Environmental Policy
    • /
    • v.13 no.2
    • /
    • pp.99-129
    • /
    • 2014
  • This research estimates the impact of population aging on energy use and carbon emissions by energy sources and by industrial sectors in Korea until 2035. For the estimation, the structural change in household consumption expenditure identified by the age-specific consumption pattern was analyzed in conjunction with energy and environment input-output tables. The estimation result presents that, despite the population aging, energy use and carbon emissions induced by household consumption continue to increase until 2026, and then that elevated levels of energy use and carbon emissions will be maintained for a considerable period of time. According to the estimation by energy sources, the use of natural gas will show substantial increase while the use of crude oil will switch to a downturn at a relatively early period. According to the estimation by industrial sectors, carbon emissions in the sectors with relatively high consumption share of old households such as medical health, dwelling, lighting, heating, air-conditioning, and food will have substantial increase, whereas those in the sectors associated with education, transport, catering, and accommodation services will turn downward relatively early. In addition, the study analyzes through policy simulation the impact of aging-related policy similar to the basic pension system, which is recently being discussed for legislation, on energy use and carbon emissions.

  • PDF

The Energy-Efficient Automatic Power Controller of The Signboard using Illuminance Detector (조도 감지기를 이용한 절전형 간판 자동 전원 제어기)

  • Ra, Seung-Tak;Lim, Song-Hwan;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.188-191
    • /
    • 2016
  • In this paper, we propose energy-efficient automatic power controller which can power on and off the signboard at the specified light intensity using the Illuminance Detector. By using segmented section Classification algorithm, light intensity setup system propose variable resistor method which makes users more easy to control. Automatic light on-off system set a standard by measured illuminance data. Measured light-intensity through the Illuminance Detector are communicated with the signboard power controller with wireless communication, and it controls lighting system. In this paper, we evaluated the Energy-Efficient Automatic Power Controller of The Signboard using illuminance detector. Experimental results in lightless environment shows that the error rate is less than 3% by Accredited Testing Laboratories.

A Study on LED Energy Efficiency in Buildings through Cloud-based User Authentication in IoT Network Environment (IoT 네트워크 환경에서 클라우드 기반의 사용자 인증을 통한 건물 내의 LED에너지 효율화 연구)

  • Ahn, Ye-Chan;Lee, Keun-Ho
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.235-240
    • /
    • 2017
  • Recently, Internet of things have been applied to various fields and are becoming common in our everyday life. Everything in our daily lives is networked, interacting with each other and giving us more useful effects. In this paper, we implemented an algorithm that can illuminate the LED lighting to the authorized person 's place in the network environment connected with the authentication device only once with the user authentication. User authentication in one building User authenticated through a single user search for the location of the user's lab stored in the database using the certified information and LED lights up to the lab where the user works. Through this, unnecessary energy is generated because people do not pass frequently.

Development of a metal-halide lamp's electronic ballast (메탈핼라이드 집어등용 전자식 안정기 개발)

  • Park, Seong-Wook;Bae, Bong-Seong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.2
    • /
    • pp.116-125
    • /
    • 2013
  • Jigging and angling fishery is prevalent in the East Sea of Korea and this fishery needs many lamps to attract the fish. And the fishing boat uses 24~47 ballasts by the vessel's tonnage to turn on the fishing lamp. A 3.5kW magnetic-type ballast being currently used at many fishing boats can drive two 1.5kW metal-halide lamps. Meanwhile, this ballast has large weight (25kg) and volume. Therefore it is one of reason for the over-consumption of energy and the fire, resulted from overheat and electrical short, occurs occasionally because the ballast is installed at narrow and hot engine room. In addition, most of magnetic ballast has several problems such as periodic condenser replacement, low energy efficiency and making lamp short life, etc. So it is necessary to improve or develop newly the electronic ballast, which has to be smaller, lighter and more efficient. An electronic ballast was designed for the fishing boat by considering duration and electromagnetic interference in the study. Its weight and volume are respectably 40% and 66% compared to current ballast on the basis of PCB. The metal-halide lamp's spectrum of the designed ballast was nearly same to that of the current ballast in the test of lighting. In particular, the light stability was improved and there isn't any radio interference. As mentioned above, it is expected that the developed electronic ballast can replace current magnetic ballast because of many advantages related to energy-saving.

A Study on the Reduction of Greenhouse Gas in Container Terminal (컨테이너터미널의 온실가스 저감방안에 관한 연구)

  • Kim, Seon-Gu;Choi, Yong-Seok
    • Journal of Korea Port Economic Association
    • /
    • v.28 no.1
    • /
    • pp.105-122
    • /
    • 2012
  • This paper proposes a fuzzy-based AHP model by which the greenhouse gas reduction for container terminal problem was systematically structured and then evaluated. The model was established by exploiting a fuzzy theory and AHP for capturing the inexactness and vagueness of information. In this study, measurement areas were selected for equipment aspect, operating aspect, and energy aspect. The greenhouse gas reduction is the number one priority in the equipment aspect, operating aspect, energy aspect in order. The analysis result of equipment aspect reveals that the most important element is electrical T/C. The most important element of operating and energy aspect were a container rehandling and a LED lighting. As for the whole priority which conversion weight was applied, the results were shown as follows: an electrical T/C(16.2%) as the first rank: a hybrid Y/T(14.4%) as the second rank: a AMP(10.6%) as the third rank. The result of this study suggests some guidelines for deciding priority of greenhouse gas reduction for container terminal.

200[W] Half-Bridge LLC Series Resonant Converter for driving LED Lamp (LED 조명장치 구동용 200[W]급 하프브리지 LLC 직렬공진형 컨버터)

  • Han, Woo-Yong;Park, Hyo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4483-4488
    • /
    • 2010
  • In comparison with some other light sources, LED has merits such as long lifetime, pollution free, and high energy efficiency. Lately, due to development of LED with high brightness and capacity, LED, which has been applied in display system only, has applied in the field of lighting system. Driving current of power LED has to be controlled below the designed value. In this paper, half-bridge LLC series resonant converter, which has the current limiting function, has been described. Half-bridge LLC series resonant converter allows in relatively wide input voltage and output load range when compared to the other resonant converter. Also, it is possible to reduce a magnetic component, because leakage inductance of transformer is used as a resonant inductance. It has been validated by designing and testing 200[W] half-bridge LLC converter of DC24[V] output voltage for LED lamp driver, which includes a current limiting function and power factor correction(PFC) function.

The Study on the optimized LED module of VMS for saving energy (에너지 절감을 위한 VMS LED 모듈 최적화 연구)

  • Kim, Young-Rok;Lee, Suk-Ki
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.231-238
    • /
    • 2011
  • Variable message signs(VMS) in use are being displaying with the LED device as the luminous source, and it is a recent trend to be changed from the Lamp type to the Surface-Mount Devices(SMD) type. The LED device leads to get VMS display brightly and clearly, leading to have visibility and legibility better than the existing VMS. However, the lights which display off the road, the unnecessary energy, might have negative effect on ecosystem. This study developed the way of getting the lights be displayed only to drivers without the unnecessary energy and estimated the energy efficiency of the development by the optical testing. As a result, this study showed that the energy consumption of the developed display device appeared to decrease by about 36.1% compared to the existing device. Also the upward and downward angle of the lights changed from an angle of $24^{\circ}C$ to $0^{\circ}C$and from an angle of $-24^{\circ}C$ to $-11^{\circ}C$, respectively. Therefore, it anticipates that the developed device would benefit highway safety due to an improvement in visibility and legibility compared to the existing VMS and the energy consumption would be less lower than the existing VMS.

Earlier Metabolizable Energy Intake Level Influences Heat Production during a Following 3-Day Fast in Laying Hens

  • Ning, D.;Guo, Yuming;Wang, Y.W.;Peng, Y.Z.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.4
    • /
    • pp.558-563
    • /
    • 2013
  • The present study was conducted to estimate energy requirements for maintenance in laying hens by using indirect calorimetry and energy balance. A total of 576 28-wk-old Nongda-3 laying hens with dwarf gene were randomly allocated into four ME intake levels (86.57, 124.45, 166.63 and 197.20 kcal/kg body weight $(BW)^{0.75}$ per d) with four replicates each. After a 4 d adaptation period, 36 hens from one replicate were maintained in one of the two respiration chambers to measure the heat production (HP) for 3 d during the feeding period and subsequent 3 d fast. Metabolizable energy (ME) intake was partitioned between heat increment (HI), HP associated with activity, fasting HP (FHP) and retained energy (RE). The equilibrium FHP may provide an estimate of NE requirements for maintenance (NEm). Results showed that HP, HI and RE in the fed state increased with ME intake level (p<0.05). Based on the regression of HP on ME intake, the estimated ME requirements for maintenance (MEm) was 113.09 kcal/kg $BW^{0.75}$ per d when ME intake equals HP. The FHP was decreased day by day with the lowest value on the third day of starvation. Except for lowest ME intake level, the FHP increased with ME intake level on the first day of starvation (p<0.05). The FHP at the two higher ME intake levels were greater than that at the two lower ME intake levels (p<0.05) but no difference was found between the two lower ME intake levels. Linear regression of HP from the fed state to zero ME intake yielded a value of 71.02 kcal/kg $BW^{0.75}$ per d, which is higher than the extrapolated FHP at zero ME intake (60.78, 65.23 and 62.14 kcal/kg $BW^{0.75}$ per d for the first, second and third day of fasting, respectively). Fasting time, lighting schedules, calculation methods and duration of adaptation of hens to changes in ME intake level should be properly established when using indirect calorimetry technique to estimate dietary NE content, MEm and NEm for laying hens.

Application of LEAP Model to Reduce GHG Emissions from Residential Sector (LEAP 모형을 이용한 가정 부문 온실가스 저감효과 분석)

  • Jo, Mi-hyun;Park, Nyun-Bae;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.211-219
    • /
    • 2013
  • This study uses the LEAP model that is a long-term energy analysis model to analyze reduction potential on S city residential sector energy usage for greenhouse gas emission. Energy consumption of S-si in 2009 is consumed most in residential and commerce sector by 39.1%. Also, energy and greenhouse gas emission of residential sector is expected to increase due to increase of households. Therefore, greenhouse gas reduction measures are desperately required in residential sector. For this study recognizes energy consumption of S-si residential sector and has established reduction measure of S-si residential sector greenhouse gas through literature search on domestic and foreign climate change correspondence policies. Also, construction of greenhouse gas reduction potential by reduction measures through LEAP model. There were a total of 5 reduction measures scenarios is Reference Scenario, LED Lighting, Energy Alternative, Green Life Practice, and Total Reduction Measure. As a result, greenhouse gas emission of Light Emitting Diode Lightings by 2020 was $1,181.0thousand\;tonCO_2eq$, decrease of 6.1% compared to the Reference Scenario and Greenhouse gas emission of Energy Alternative by 2020 was $1,171.6thousand\;tonCO_2eq$, decrease of 6.8% compared to the Reference Scenario. Greenhouse gas emission of Green Life Practice by 2020 was $1,128.7thousand\;tonCO_2eq$, decrease of 10.2% compared to the Reference Scenario. For Total Reduction Measures by 2020 emission was $966.9thousand\;tonCO_2eq$, decrease 23.1% compared to Reference Scenario.

Model of Water, Energy and Waste Management for Development of Eco-Innovation Park ; A Case Study of Center for Research of Science and Technology "PUSPIPTEK," South Tangerang City, Indonesia

  • Setiawati, Sri;Alikodra, Hadi;Pramudya, Bambang;Dharmawan, Arya Hadi
    • World Technopolis Review
    • /
    • v.3 no.2
    • /
    • pp.89-96
    • /
    • 2014
  • Center for Research of Science and Technology ("PUSPIPTEK") has 460 hectares land area, still maintained as a green area with more than 30% green space. There are 47 centers for research and testing technology, technology-based industries, and as well as public supporting facilities in PUSPIPTEK area. Based on the concepts developed to make this area as an ecological region, PUSPIPTEK can be seen as a model of eco-innovation. The purpose of this research is to develop a model of water, energy and waste management with eco-innovation concept. As a new approach in addressing environmental degradation and maintaining the sustainability of ecosystem, studies related to eco-innovation policy that combines the management of water, energy and waste in the region has not been done. In order to achieve the objectives of the research, a series of techniques for collecting data on PUSPIPTEK existing conditions will be carried out, which includes utilities data (water, electricity, sewage) and master plan of this area. The savings over the implementation of the concept of eco-innovation in water, energy, and waste management were calculated and analyzed using quatitative methods. The amount of cost savings and feasibility were then calculated. Eco innovation in water management among other innovations include the provision of alternative sources of water, overflow of rain water and water environments utilization, and use of gravity to replace the pumping function. Eco-innovation in energy management innovations include the use of LED and solar cell for air conditioning. Eco-innovation in waste management includes methods of composting for organic waste management. The research results: (1) The savings that can be achieved with the implementation of eco innovation in the water management is Rp. 3,032,640 daily, or Rp.1,106,913,600 annually; (2) The savings derived from the implementation of eco innovation through replacement of central AC to AC LiBr Solar Powered will be saved Rp.1,933,992,990 annually and the use of LED lights in the Public street lighting PUSPIPTEK saved Rp.163,454,433 annually; (3) Application of eco innovation in waste management will be able to raise awareness of the environment by sorting organic, inorganic and plastic waste. Composting and plastic waste obtained from the sale revenue of Rp. 44,016,000 per year; (4) Overall, implementation of the eco-innovation system in PUSPIPTEK area can saves Rp. 3,248,377,023 per year, compared to the existing system; and (5)The savings are obtained with implementation of eco-innovation is considered as income. Analysis of the feasibility of the implementation of eco-innovation in water, energy, and waste management in PUSPIPTEK give NPV at a 15% discount factor in Rp. 3,895,228,761; 23.20% of IRR and 4.48 years of PBP. Thus the model of eco-innovation in the area PUSPIPTEK is feasible to implement.