• Title/Summary/Keyword: Light switch effect

Search Result 14, Processing Time 0.025 seconds

A study on the characteristic of Pockel cell Q-switch for Nd:YAG laser (Nd:YAG Laser를 위한 포켓셀 Q-스위치특성 연구)

  • Kim, Whi-Young
    • Journal of Digital Contents Society
    • /
    • v.10 no.2
    • /
    • pp.199-207
    • /
    • 2009
  • The Q-switching the shutter or the different optical science element puts in within the laser light resonator and the storehouse departs from the within the resonator it loses the mortar and the reversal distribution which when is sufficient creates from within the active medium, opens the shutter instantaneously and it is to do to be made to emit with the light where the energy which is accumulated within the resonator is strong very. Like this Q-switching of laser resonator--It decreases factor increasing suddenly to make. To method of Laser Q-switching mechanical switching methods, electro-optic switching methods and switching by saturable absorber methods, acousto-optic switching method etc. 4 kind are being used on a large scale. In these people the conversion which is electric in compliance with the effect which is electrooptics is widely being used the Q-switching pulse of short pulse width because being it will be able to create. Consequently, Pockel cell where it has the quality of electrooptics effect) the Q-it is become known that it is suitable it uses with switch. From the research which it sees FET and one-chip microprocessor where it is a switching element and pulse transfomer to plan and produce pockel cell Q-switch driving gears, pulse style Nd: It applied in YAG Laser system and it investigated and researched the operating characteristic of the Q-switch. Also, the Q-switch leads and Nd where it is output: YAG with forecast in compliance with a theoretical calculation it comes to buy laser beam side politics it compared and laser beam qualities which had become Q-switching it analyzed.

  • PDF

Development of Trenched SOI 1X2 Thermo-Optic Switch for Improvement of Thermal Diffusion Effect (열확산 효과 개선을 위한 트렌치 구조의 SOI 1X2 열광학 스위치 개발)

  • 박종대;서동수;이기수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1255-1260
    • /
    • 2003
  • In order to reduce driving power consumption, we propose and fabricate a new structure of asymmetric SOI 1${\times}$2 thermo-optic switch that has a back side silicon trenched structure. Compared to conventional SOI thermo optic switches without heat sink structure, it shows an improvement of switching power reduction from about 4 watt to 1.8 watt without sacrificing cross talk of about 20 ㏈ at the light wavelength of 1.55 $\mu\textrm{m}$. Here we also described the main design consideration and fabrication procedure for the proposed device.

Emission Detection of Mercuric Ions in Aqueous Media Based-on Dehybridization of DNA Duplexes

  • Oh, Byul-Nim;Wu, Qiong;Cha, Mi-Sun;Kang, Hee-Kyung;Kim, Jin-Ah;Kim, Ka-Young;Rajkumar, Eswaran;Kim, Jin-Heung
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3223-3228
    • /
    • 2011
  • To quantify the presence of mercuric ions in aqueous solution, double-stranded DNA (dsDNA) of poly(dT) was employed using a light switch compound, $Ru(phen)_2(dppz)^{2+}$ (1) which is reported to intercalate into dsDNA of a right-handed B-form. Addition of mercuric ions induced the dehybridization of poly(dT)${\cdot}$poly(dA) duplexes to form a hairpin structure of poly(dT) at room temperature and the metal-to-ligand charge transfer emission derived from the intercalation of 1 was reduced due to the dehybridization of dsDNA. As the concentration of $Hg^{2+}$ was increased, the emission of 1 progressively decreased. This label-free emission method had a detection limit of 0.2 nM. Other metal ions, such as $K^+$, $Ag^+$, $Ca^{2+}$, $Mg^{2+}$, $Zn^{2+}$, $Mn^{2+}$, $Co^{2+}$, $Ni^{2+}$, $Cu^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Fe^{3+}$, had no significant effect on reducing emission. This emission method can differentiate matched and mismatched poly(dT) sequences based on the emission intensity of dsDNA.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

Design of Thermo-optic Switch with Low Power Consumption by Electrode Optimization (전극 구조의 최적화를 통한 저전력 열광학 스위치 설계)

  • Choi, Chul-Hyun;Kong, Chang-Kyeng;Lee, Min-Woo;Sung, Jun-Ho;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.266-271
    • /
    • 2009
  • We designed a thermo-optic switch based on a directional coupler with not only a high extinction ratio but also significantly low power consumption. The switch operates by using the thermo-optic effect of the polymer which the refractive index changes by heating the electrode. If the electrode is not powered (OFF), the input light will be coupled completely to the other waveguide. When the electrode is powered at a certain level (ON), input light launched into the input waveguide will remain in that waveguide due to the lower index adjusted in the other waveguide. The switch based on the directional coupler was designed using the generalized extinction ratio curve and the lateral shift of the input waveguide. The coupling length is 1,610 ${\mu}m$ and the extinction ratios are -28 and -30 dB for ON and OFF states, respectively. The electrode structures were optimized by thermal analysis. The transported heat into the waveguide is increased, as the electrode width (w) is increased and the center distance between the electrode and the waveguide (d) is decreased. Also, because the heat generated in the electrode affects the other waveguide, the temperature difference between two waveguides is varied as the given w and d. There are specific conditions which have the maximum of the temperature difference. That of the temperature difference is increased as the width and the temperature of the electrode are increased. Especially, when the switch is designed using the condition with the maximum of the temperature difference for switching, the temperature of the electrode can be decreased. We expect this condition will be the novel method for the reduction of the power consumption in a thermo-optic switch.

Quantitative Analysis for the Effect of Sensory Information on the Motor (감각정보의 차이가 운동에 미치는 영향에 대한 정량적 분석)

  • 홍철운;심해영;박찬희;김남균
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.165-170
    • /
    • 2002
  • The aim of this study was to analyze the effect of different sensory information on the motor function which is resulted from visual stimuli. Particularly, it was focused on the effect of complementary color stimuli on reaction time. Twenty volunteers(10 men & 10 women), between the age of 20 and 25 yearn participated in this experiment. Experiments were carried out in a light & sound-attenuated chamber, and the overall system consisted of a PC. interface card. LEDs. key board switch, and display panel. Although many measurements of sensory-motor integration has been studied the quantitative analysis of sensory-motor integration has not been developed well. Quantitative analyses were performed to investigate the effect of the different sensory information on the arm motor system in the point of view sensory-motor integration. The result showed that the reaction time for visual stimuli of complementary colors was faster than that under same color environments : and, in same color environments and the reaction speed was varied inversely with respect to the magnitude of the light wavelength.

A Study on a KTP Crystal Laser System for a Cancer Using P.D.T. (KTP 크리스탈을 이용한 PDT용 레이저 시스템 개발)

  • Kim, Byoung-Mun;Nam, Hyo-Duk;Kim, Byoung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.631-634
    • /
    • 2004
  • The method that exists in Photodynamic Therapy uses Photosensibility drug strongly Influencing tumour accumulation together with photochemical laser effect and makes the structure of tumour be localized and become extinct. The intracavity transformation of the Nd :YAP main radiation 1079 nm was Raman converted in barium nitrate crystal and the Stokes frequency (1216 nm) was doubled using KTP or RTA crystals. The LiF or Cr:YAG crystals are used for the Q-switch. The radiation Parameters were obtained at 100 Hz pump repetition frequency. The average power at 608 nm radiation with LiF and KTP was 700 mW at multi-mode generation. The 3-6 single 10-15 ns pulses were generated during one cycle of pumping. The doubling efficiency with RTA was two times more than with KTP. The cells of Ehrlich adenocarcinoma (0.1 ml) were i.m. implanted in hind thighs of ICR white non-imbred mice. The cells were preliminarily diluted in medium 199 in the ratio of 1 to 5. HpD was intravenous administered in a dose of 10 mg/kg. The left clean-shaven hind leg was irradiated with laser light 21-27 hours after the administration of the preparation. The right non-Irradiated leg of each animal served as a control. The animals with the transplanted tumor that were not injected with HpD sewed as a control to estimate the complex effect (HpD+ irradiation). Before the administration of HpD and on 3 and 4 days after irradiation the tumor size was measured and the percent of the tumor growth inhibition was calculated. The results of animal treatments has shown high efficiency of PDT method for cancer treatment by means 0.608 m high power pulse solid state laser.

  • PDF

A Study on the Continuous Current Mode $S^4$-PFC Converter using Auxiliary Resonant Circuit (공진형 보조 회로를 이용한 연속 전류 모드 $S^4$-PFC 컨버터에 관한 연구)

  • Han, Dae-Hee;Kim, Yong;Bae, Jin-Yong;Lee, Eun-Young;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.200-203
    • /
    • 2002
  • This paper presents Continuous-current mode of $S^4$-PFC(Single-Stage Single-switch Power Factor Correction) converter. Proposed converter operates in the continueous current mode(CCM) at full load and discontinuous current mode(DCM) at light load. So, characteristic of proposed converter is no bus voltage stress and Zero Voltage Switching(ZVS) using resonant auxiliary circuit. And. This paper presents characteristic of $S^4$-PFC converter and effect of circuit parameter of proposed converter through the input inductor, PFC capacitor's variation. All of these theory and characteristic verified through the experiment with a 72W(12V, 6A), $90^{kHz}$ prototype converter.

  • PDF

Development of Minimally Invasive Mid-infrared Lipolysis Laser System for Effective Fat Reduction

  • Lee, Ji-Young;Ryu, Han Young;Seo, Young-Seok
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.82-89
    • /
    • 2021
  • Background and Objectives Due to changes in diet and lifestyle, the number of obese people worldwide is steadily increasing. Obesity has an adverse effect on a healthy life, so it needs treatment and improvement. Research related to this is continuously being conducted. Materials and Methods The laser system to compact designed using 808 nm laser diode and Neodymium Yttrium orthovanadate generates a 1064 nm wavelength, the periodically polarized nonlinear crystal pumping laser beam. The pulsed 1064 nm wavelength beam passing through the AO Q-switch is used as the pumping light of the nonlinear optical crystal and is irradiated to the periodic polarized nonlinear optical crystal with a quasi-phase matching period. Nonlinear optical crystals use an oven to control the temperature to generate the desired 1980 nm and 2300 nm wavelengths. Results The 1980 nm and 2300 nm wavelengths generated by temperature control of nonlinear optical crystals are effective for lipolysis. A fiber catheter was used so that the laser could be directly irradiated to the fat cells. In particular, the new wavelength (1980 nm, 2300 nm) can increase the fat reduction effect with low energy (1.3 W). When a laser with a combination wavelength of 1980 nm and 2300 nm was used, an average lipolysis effect of 20% was obtained. Conclusion A mid-infrared lipolysis laser system with excellent absorption of fat and water has been developed. We conducted a princlinical study to confirm the efficacy and safety of the lipolysis laser system, and obtained good results for lipolysis with low energy.

Sterilization Effect by the Nd:YAG Laser pulse (Nd:YAG 레이저 펄스에 따른 멸균효과)

  • Jeong, Kyeonghwan;Jung, Dongkyung;Park, Jeongkyu;Choi, Hyeonwoo;Seo, Jeongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.695-703
    • /
    • 2020
  • The use of medical devices is increasing due to the development of medical technology. Among medical devices, it is often used in the human body for graft and treatment. Therefore, in medical institutions, various sterilization methods according to the type and material of medical devices are applied to prevent infection. Hydrophosphite (HA) materials are the most popular in bone grafts. We would like to present a sterilization method using Q-switch Nd:YAG laser with high output energy among non-ionizing radiation suitable for small medical devices. In this study, sterilization power was most ideally shown at UV wavelengths of 1.5 W, 266 nm, and 10 pulses. Different wavelength bands; infrared and visible light; showed passive sterilization, and ultraviolet A and C showed differences in sterilization according to the pulse. In laser sterilization were differences that found according to the wavelength bands and pulses.