• 제목/요약/키워드: Light fluorescence

검색결과 557건 처리시간 0.033초

형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석 (Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements)

  • 이용근;박현미;이동수;이보경
    • 한국대기환경학회지
    • /
    • 제9권3호
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

형광(螢光)을 이용한 식품(食品) 방부제의 검사(檢査) (Detection of Chemical Preservatives by the Use of Fluorescence)

  • 이미순
    • 한국식품과학회지
    • /
    • 제11권3호
    • /
    • pp.166-170
    • /
    • 1979
  • UVSL-25 mineral light를 조사(照射)한 경우에 발생하는 식품(食品) 보존료(保存料) 자체(自體)의 형광(螢光)을 이용하여 신속하고 간편하게 보존료(保存料)를 검사(檢査)할 수 있는 방법(方法)을 시도(試圖)하였다. 유동(流動) 파라핀에 현탁(懸濁)된 분말(粉末) 시료(試料)의 흡수(吸收) 및 발광(發光) 스펙트럼은 보존료(保存料)의 종류에 따라 특징적인 패턴을 나타냈다. 장파장(長波長) 측(側) 및 단파장(短波長) 측(側) 영역(領域)의 자외선(紫外線) 조사(照射)에서 얻은 스펙트럼 특성을 대조(對照)하여 비교하므로써 보존료(保存料)의 종류가 보다 용이하게 판별되었다.

  • PDF

입자 이동 방식에서 Laser Induced Fluorescence와 뭉침에 관한 연구 (A Study on Laser Induced Fluorescence and Coagulation in Particle Transport Mode)

  • 김기준
    • 한국응용과학기술학회지
    • /
    • 제23권4호
    • /
    • pp.340-346
    • /
    • 2006
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF). The effects of optical properties in scattering media have been found by the optical $parameters({\mu}_s,\;{\mu}_a,\;{\mu}_t)$. Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process, The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, biopharmaceutical products, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

근적외선 형광 영상 시스템용 다채널 영상 모듈 개발 및 패키징 (Development and Packaging of Multi-channel Imaging Module for Near-infrared Fluorescence Imaging System)

  • 김태훈;서경환;이학근;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제26권2호
    • /
    • pp.59-64
    • /
    • 2019
  • 본 논문에서는 근적외선 다채널 형광 영상 시스템을 소개하고, 노출시간, 작동거리, 여기광의 강도에 따른 형광 영상 시스템의 특성에 대해 분석하였다. 노출시간이 길수록, 작동거리가 짧을수록, 여기광의 강도가 강할수록 형광신호가 증가하였다. 필터의 적절한 구성과 영상 모듈의 정밀한 패키징으로 배경신호의 증가를 억제하여 SBR이 증가하는 것을 확인하였다. 본 연구의 결과를 바탕으로 다채널 형광 영상 시스템을 활용할 수 있는 방안에 대해 제안하였다.

Optical Imaging Technology for Real-time Tumor Monitoring

  • Shin, Yoo-kyoung;Eom, Joo Beom
    • Medical Lasers
    • /
    • 제10권3호
    • /
    • pp.123-131
    • /
    • 2021
  • Optical imaging modalities with properties of real-time, non-invasive, in vivo, and high resolution for image-guided surgery have been widely studied. In this review, we introduce two optical imaging systems, that could be the core of image-guided surgery and introduce the system configuration, implementation, and operation methods. First, we introduce the optical coherence tomography (OCT) system implemented by our research group. This system is implemented based on a swept-source, and the system has an axial resolution of 11 ㎛ and a lateral resolution of 22 ㎛. Second, we introduce a fluorescence imaging system. The fluorescence imaging system was implemented based on the absorption and fluorescence wavelength of indocyanine green (ICG), with a light-emitting diode (LED) light source. To confirm the performance of the two imaging systems, human malignant melanoma cells were injected into BALB/c nude mice to create a xenograft model and using this, OCT images of cancer and pathological slide images were compared. In addition, in a mouse model, an intravenous injection of indocyanine green was used with a fluorescence imaging system to detect real-time images moving along blood vessels and to detect sentinel lymph nodes, which could be very important for cancer staging. Finally, polarization-sensitive OCT to find the boundaries of cancer in real-time and real-time image-guided surgery using a developed contrast agent and fluorescence imaging system were introduced.

무질서한 매질에서 침투깊이와 파동 전파 (Penetration depth and Wave Propagation in Random Media)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제23권1호
    • /
    • pp.70-76
    • /
    • 2006
  • The influence of fluorophor, scatterer, absorber in turbid materials by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it is studied the molecular property by laser induced fluorescence spectroscopy. It can be found that the effects of optical property are penentrated in scattering media by the optical $parameters({\mu}s$, ${\mu}a$, ${\mu}t$, ${\gamma}$, ${\rho})$. The value of scattering coefficient ${\mu}s$ is large appeared by means of the increasing particles of scattering, it can be found that the slope appears exponentially as a function of distance from laser source to detector. It may also utilize in designing the best model for oil chemistry, laser medicine and application of medical engineering.

Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구 (A Study on Spectra of Laser Induced Fluorescence in Phantom)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.329-335
    • /
    • 1999
  • The influences of fluorophor, scatterer, and absorber in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength. The molecular properties have been studied by laser induced fluorescence spectroscopy in phantom. It has been found that the effects of optical properties in scattering media could be investigated by the optical parameters(${\mu}_a$, ${\mu}_a$, ${\mu}_t$). Experimental and Monte Carlo Simulation method for modelling light transport in tissue was applied. The experimental results using a phantom were discussed and compared with those obtained through Monte Carlo Simulation. It may also aid in designing the best model for oil chemistry, medicine and application of medical engineering.

오이 잎에서 저온 광저해에 의한 형광유도과정의 초기 변이와 스트레스 지표 (Early Alterations of Chlorophyll Fluorescence by Light-Chilling in Cucumber (Cucumis sativus) Leaves and Their Usage as Stress Indicators)

  • Ha, Suk-Bong;Young-Jae Eu;Choon-Hwan Lee
    • The Korean Journal of Ecology
    • /
    • 제19권2호
    • /
    • pp.151-163
    • /
    • 1996
  • To investigate the early symptoms of light-chilling, alterations of chlorophyll fluorescence transients were monitored in cucumber (Cucumis sativus L. cv. Ilmichungjang) leaves. During 24 h chilling, decreases in (Fv)m/Fm, qE and qQ, and an increase in Fo were observed. The chilling effects were not recovered at room temperature, and a significant increase in Fo was observed during the recovery period. After 6 h chilling, ‘dip’(D) level of the transients became obscure, and the negative slope after ‘peak’(P) disappeared. The first derivative (dFv/dt) of the fast fluorescence rise curve was used to obtain more accurate information about the changes in the transients. The maximal rate of the fluorescence increase in the D-p rise curve (Fr) has been the most frequently used chilling stress indicator. However, a correct value of Fr could not be measured when the D level became obscure. This problem was overcome by introducing a new indicator, HFr (dFv/dt at Fv = 1/2 (Fv)m), and HFr gave very similar values to Fr. To monitor the changes in curvature around D level, another new parameter, ${\Delta}S$(D-Fr), was also introduced. These three parameters decreased very sensitively during light-chilling. In addition, increases in these parameters were observed during the first 2 h chilling, but this increase in Fr was also observed in pea leaf discs dark-chilled for 15 min, suggesting that this very early change is a common response to chilling in both pea and cucumber leaves. Quenching coefficients were also very sensitive to chilling, especially qE. Discussion on the usage of these parameters as chilling stress indicators is given in the text.

  • PDF

The Effect of Light Intensity on the Growth and Chlorophyll Fluorescence Parameters of Three Ardisia Genus Native to Korea

  • Bo Kook Jang;Kyungtae Park;Cheol Hee Lee;Sang Yeob Lee;Ju Sung Cho
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2020년도 춘계학술대회
    • /
    • pp.55-55
    • /
    • 2020
  • This study investigated the growth and chlorophyll fluorescence reactions of three Ardisia genus grown under various indoor light intensity conditions with the aim of evaluating their suitability as indoor plants. Young seedlings of A. crispa (Thunb.) A.DC., A. pusilla DC., and A. japonica (Thunb.) Blume were used in the experiment. The plants were cultivated indoors for 10 weeks under different light intensities: 10, 50, 100, and 200 PPFD (μmol·m-2·s-1), and their growth was compared with that of plants cultivated in a greenhouse during the same period (mean value 236.8±20.4 PPFD at noon). Also, chlorophyll fluorescence analysis was investigated with a portable PAM fluorometer. The indoor plants were maintained at 12/12 h photoperiod, temperature at 25±1℃, and humidity at 55±3%. Irrigation frequency (once every three days) was the same for the indoors and the greenhouse. The results of growth in three Ardisia plants showed that almost all parameters except leaf number and chlorophyll content had similar levels regardless of light intensity. A. crispa and A. pusilla plants grown in 200 PPFD were investigated to have low chlorophyll contents. Meanwhile, chlorophyll fluorescence parameters differed based on light levels. In A. crispa, the Fv/Fm (0.77), DIo/RC (0.47) and Fm/Fo (4.77) parameters tended to be poor at 200 PPFD compared to those at other light intensities. Similarly, the DIo/RC, Fm/Fo, and Pi_Abs parameters of A. pusilla plant (200 PPFD) are 0.45, 4.48 and 2.42, respectively, which can be considered stress. The analysis of fluorescence in A. japonica showed that all parameters except ETo/RC had similar levels regardless of light intensity. The ETo/RC parameter was 0.49 and 0.72 in the control plants and plants 200 PPFD, respectively, which was lower than those in plants at other light intensities. Therefore, it seems that the relatively high light intensity acted as a stressor for Ardisia plants.

  • PDF

CHILLING SENSITIVITY OF CUCUMBER PLANTS MONITORED IN TERMS OF CHLOROPHYLL FLUORESCENCE

  • Kang, In-Soon;Moon, Byoung-Yong;Seo, Kye-Hong;Chun, Hyun-Sik;Lee, Chin-Bum
    • Journal of Photoscience
    • /
    • 제3권1호
    • /
    • pp.9-14
    • /
    • 1996
  • For three cultivars of chilling-sensitive cucumber plants, chilling sensitivity was evaluated in terms of photosynthetic activity using Chl fluorescence techniques. Low-temperature treatment caused a decrease in photosynthetic activities of cucumber leaves, measured as CO$_2$ exchange, as well as the decrease in the stomatal conductance. FR of the three cultivars decreased after chilling for 24 h in light and the extent of decline of F$_R$ was the greatest in 'Chosaeng' cultivar. When these plants were recovered from light-chilling, 'Chosaeng' and 'Samchuk' cultivars did not fully restore the original value of F$_R$ after 24 h of recovery, in contrast to 'Ilmi' cultivar which showed a rather efficient recovery. The results of FR study showed that 'Chosaeng' was most susceptible, whereas Ilmi was most resistant, to chilling among the three cultivars of cucumber plants. When quenching coefficients for chlorophyll fluorescence was analyzed after chilling the cucumber plants for 24 h in light, 'Chosaeng' elicited more rapid declines in the coefficients for photochemical quenching (qQ), non-photochemical quenching (qNP) and energy-dependent quenching (qE) than 'Ilmi' and 'Samchuk'. The implications of these observations are discussed in relation to the growth habits of the respective cultivars in the field. The results showed that measurement of chlorophyll fluorescence was an effective means of screening chilling tolerance of cucumber plants. Furthermore, the study on the chlorophyll fluorescence induction and fluorescence quenching charactersitics showed that low temperature could accelerate inhibition of photosynthesis in chilling-sensitive plants, by limiting Calvin cycle activity and disrupting, in part, the energy dissipation mechanims of the photosystem II.

  • PDF