• Title/Summary/Keyword: Light fixture

Search Result 52, Processing Time 0.02 seconds

펜던트형 감성조명 LED 등기구 모듈개발

  • Seo, Dong-Won;Kim, Yeong-Geun;Kim, Jin-Sa;Kim, Geum-Taek;Choe, Un-Sik;Song, Min-Jong;Song, Myeong-Hyeon;Park, Chun-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.264-264
    • /
    • 2009
  • The sensitivity lighting of pendant type used Micro-controller AVR, embodiment method for Munsell chromaticity diagram system and adoption method for light source lens respectively. About a plan design of light fixture, LED circuit designed flow chart of circuits and LED driver of organizations in electron device. For used Solidworks soft ware program, LED light source must take a heat shink part and LED light fixture module for sensitivity lighting of pendant type into considerations

  • PDF

A Study on the Convertible Emergency Lighting Fixture in Consideration of Dark Adaptation (암순응을 고려한 겸용형 비상조명등에 관한 연구)

  • Yum, Sung-Bae;Yoon, Cheol-Gu;Lee, Jung-Eun;Shin, Hye-Young;Song, Young-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.24-29
    • /
    • 2011
  • When an emergency light turns on due to a blackout, the intensity of illumination is drastically changed from hundreds [1x] to 1.0[1x]. This sharp change of illumination intensity not only lowers the darkness adaptation of the eye, it also degrades the obstacle cognitive ability of the evacuees, resulting in secondary critical accidents due to anxiety, and fear. Thus, this study proposed a convertible emergency lighting fixture that controls the rate of speed of light in two stages by time with darkness adaptation of the eye in consideration. In addition, the effect of such emergency light is verified by suggesting an illumination simulation without increasing the number of light or capacity of battery to make it economically feasible.

A Field Investigation on Light Trespass of Residential Buildings by Street Lighting (주거지역에서 가로조명에 의한 침입광발생 분석)

  • Ha, Na;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2010
  • Spill light by street lighting is a kind of light pollution creating cozy night atmosphere, interfere visual private and cause insomnia at night. This study was to survey light trespass of the windows in residential buildings. According to outdoor lighting control guidance in Seoul, three different areas were selected to investigate the trespass light to windows. The results were as follows: 37% of the buildings of 386 buildings were influenced by street lighting, and 47% of windows were occurred light trespass. Therefore, the street lighting affected light trespass at night in survey area. The main reasons of light trespass were luminaire type, luminaire pole height, and street width. For protecting the light trespass to windows, it is necessary to non-cutoff fixture to full cutoff fixture by the street width.

Analysis of the Heat Radiation of LED Light Fixture using CF-design (LED조명기구의 CF-Design 방열 해석)

  • Eo, Ik-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1565-1568
    • /
    • 2008
  • This thesis is about the design of heat sink which is the obstacle in commercializing LED light fixture. It suggests a way of solving the problem by the analysis on heat radiation of LED light fixture using CF-design. As a result of the analysis, the difference of simulation value and the measured temperature of proto-type was derived as less than 6[$^{\circ}C$]. Even the results approaching the target value of actual product could be obtained with the given factors well applied.

A Study on a Novel LED Lighting Fixture for Crosswalk Having Two Different Light Distributions (두 가지 배광을 갖는 LED 횡단보도 조명장치에 관한 연구)

  • Kim, Hyeong Jin;Lee, Dong Kyu;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.606-611
    • /
    • 2014
  • Recently, LED lighting fixtures for crosswalk become popular in order to recognize the pedestrians at crosswalk, which can enhance the safety of the pedestrian at crosswalk. However, there are several problems related to the LED lighting fixtures for crosswalk, such as a lot of energy consumption due to a constant illumination during night and glaring of pedestrians at the opposite side of crosswalk. In this study, in order to overcome these problems, we have investigated a novel LED lighting fixture for crosswalk, which has two modules with different angles ($60^{\circ}$, $120^{\circ}$). Illuminance of min and max at four-line city street crosswalk shown 50 Lux, 125 Lux, respectively. Illuminance of min and max at eight-line city street crosswalk shown 150 Lux, 200 Lux, respectively. Simulation investigation was optimized design using optical program. Prototype was verified measurement by goniometer system.

Interior heating effect in an office building according to heat properties of light fixture (업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구)

  • Lee, Yoon-Jin;Ahn, Byung-Lip;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Kim, Tae-Yeon
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

A Study on the Replace Broadcasting Image Lighting of use the LED (LED조명으로 방송스폿조명 대치방안에 관한 연구)

  • Lee, Jang-Weon;Gwon, Gi-Tae;Roh, Jae-Yup;Lee, Jin-Woo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.103-105
    • /
    • 2009
  • A Study on the Replace Broadcasting Image Lighting fixture of LED so electrical charges, eye many of be dazzling, very hot of tungsten halogen light fixture take a photograph studio image in low space studio

  • PDF

Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp (백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

An Educational Program of Luminaire Design based on Component Attributes (성분적 속성에 기초한 조명기구디자인 교육프로그램)

  • 박우성
    • Archives of design research
    • /
    • v.14 no.2
    • /
    • pp.57-66
    • /
    • 2001
  • This research was carried with emphasis on the technical contents of lighting design which had various knowledge system in the educational viewpoint. First of all, phisiolosical and physical factors were considered with the process of vision between human and light. Next, components of attributes in the lighting fixture were prescribed to analyze concept of the fixture. Finally, I proposed educational program in the instruction to meet the purpose of this research. As a result, in overall research concerning the basic direction and structure, instruction should have balance to reconcile theory and practice about lighting. Second, in terms of expansion of cognition about lighting, experimental education that is considered with interface is needed to make practical verification through relationship with man-made environment and scientific data.

  • PDF

Development of 36[W] LED Fixtures for the Broadcasting Spot Lighting (방송 스폿 조명등기구 36[W]급 LED 등기구 개발)

  • Lee, Jang-Weon;Im, Jee-Weon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.127-135
    • /
    • 2010
  • A study on that LED in 36[W] class replaces broadcast illuminator to save energy and improve the quality of film because tungsten halogen illuminators are too hot and spending lots of electrical capacity at the time of camera shooting. And the following result was obtained .36[w] LED lighting fixture's illuminance is lower than 1[kw] halogen Light but object's illuminance became higher, and at the image be showed very bright and softly.