• 제목/요약/키워드: Light Wall

검색결과 624건 처리시간 0.026초

Seismic reliability evaluation of steel-timber hybrid shear wall systems

  • Li, Zheng;He, Minjuan;Lam, Frank;Zhou, Ruirui;Li, Minghao
    • Earthquakes and Structures
    • /
    • 제13권3호
    • /
    • pp.289-297
    • /
    • 2017
  • This paper presents seismic performance and reliability evaluation on steel-timber hybrid shear wall systems composed of steel moment resisting frames and infill light frame wood shear walls. Based on experimental observations, damage assessment was conducted to determine the appropriate damage-related performance objectives for the hybrid shear wall systems. Incremental time-history dynamic analyses were conducted to establish a database of seismic responses for the hybrid systems with various structural configurations. The associated reliability indices and failure probabilities were calculated by two reliability methods (i.e., fragility analysis and response surface method). Both methods yielded similar estimations of failure probabilities. This study indicated the greatly improved seismic performance of the steel-timber hybrid shear wall systems with stronger infill wood shear walls. From a probabilistic perspective, the presented results give some insights on quantifying the seismic performance of the hybrid system under different seismic hazard levels. The reliability-based approaches also serve as efficient tools to assess the performance-based seismic design methodology and calibration of relative code provisions for the proposed steel-timber hybrid shear wall systems.

유리섬유복합소재를 이용한 지중매설형 승하강식 홍수방지 벽체구조물 (Eco-Moving Wall for a Preventing Floods using Glass Fiber Reinforced Composite)

  • Yun, Youngman
    • 한국재난정보학회 논문집
    • /
    • 제9권4호
    • /
    • pp.462-468
    • /
    • 2013
  • 제방 월류방지 대체공법으로 전도식, 부력식 홍수방지벽을 국내 외에서 개발하는 실정이다. 그러나, 사전점검 불가 및 유지관리 문제점이 있어 본 연구에서는 국내 외 최초로 경량 재질이면서 강도가 우수한 유리섬유복합소재를 이용한 승하강식 홍수방지 벽체구조물을 연구 개발하였다. 개발된 홍수방지 벽체구조물은 수치해석을 통해 구조적 안정성과 함께 현장 적용성을 제시하여 공사비를 약 87%~95%로 감소시키고 벽체구조물 내부에 고무 지수부재를 설치하여 차수성이 확보되는 것을 확인하였다.

실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석 (A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds)

  • 현인탁;이재호;윤여범;이광호
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

천장 및 벽구성 방법에 따른 바닥충격음 특성평가 (Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

Bottom ash를 이용한 경량판넬의 특성 연구(2) (A Study on the acoustic characteristic of the Light weight Concrete Pallet using bottom ash)

  • 정갑철;이성호;정진연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.384-387
    • /
    • 2006
  • Recently, the method of the apartment building design has been changed from wall type structures to moment structures. With like this reason, dry walls we used plentifully. Especially, the gypsum board was used from previously plentifully however the weak point of it is difficult to maintain because it weak strength. For the improvement of gypsum board, light weight concrete panel using cement board is used recently. As this study is the research of the series t on the development of non-bearing light weight concrete panel using bottom ash, the purpose of this study is to obtain basic data for application in the field. The results are that the structure 1 satisfies domestic standard concerned with sound insulation between households at the laboratory and field test.

  • PDF

Bottom ash를 이용한 경량판넬의 특성 연구 (A Study on the acoustic characteristic of the Light weight Concrete Panel using bottom ash)

  • 이성호;정갑철;정진연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1379-1382
    • /
    • 2006
  • Recently, the method of the apartment building design has been changed from wall type structures to moment structures. With like this reason dry walls are used plentifully. Especially, the gypsum board was used from previously plentifully however the weak point of it is difficult to maintain because it weak strength. For the improvement of gypsum board, light weight concrete panel using cement board is used recently. As this study is the research of the series t on the development of non-hearing light weight concrete Panel using bottom ash, the Purpose of this study is to obtain basic data for application in the field. The results are that the structure 1 satisfies domestic standard concerned with sound insulation between households at the laboratory and field test.

  • PDF

저회를 이용한 경량판넬의 특성 연구 (A Study on the Acoustic Characteristic of the Light Weight Concrete Panel Using Bottom Ash)

  • 정갑철;정진연
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.149-154
    • /
    • 2007
  • Recently, the method of the apartment building design is changing from wall type to moment structure. Dry walls are used plentifully. Until now, the gypsum board is used mainly but it has many problems. For improving the problems, the light weight concrete panel using cement board is used recently. The purpose of this study is to obtain basic data for the light weight concrete panel using bottom ash. As a result, some structures satisfies domestic standard concerned with sound insulation between households at the laboratory and field test.

Uniform Side Illumination Generated from LEDs Arranged by an Annealing Algorithm

  • Wang, Xu;Lei, Panling;Qian, Chaoyi;Wang, Zhiping;Xu, Xuefen;Su, Zhouping
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.332-336
    • /
    • 2022
  • Given a cubic space, it is easy to uniformly illuminate the floor with light sources placed on top. However, little has been reported about uniform illumination on walls with the same configuration of light sources. Here we present a luminaire consisting of nine light-emitting diodes (LEDs) with perfect Lambertian distribution, placed on the top as a 3 × 3 rectangular LED array. The distances between LEDs and tilt angles of each individual LED are adjustable and optimized by an annealing algorithm. After optimization, the array produces a rectangular illumination pattern on one wall with a uniformity of about 89%. Analysis shows that the tilt angles of individual LEDs are key parameters for uniform side illumination. In a scenario that is more practical, the tilt angles of all the LEDs are set to be the same, only decreasing the uniformity to 83%.

간접 조명 환경 실내 가시광 통신의 채널 모델 (VLC Channel Model Considering Indirect Light)

  • 이정훈
    • 한국통신학회논문지
    • /
    • 제38C권8호
    • /
    • pp.706-712
    • /
    • 2013
  • 본 논문에서는 간접 조명 환경에서 가시광(VLC : Visible Light Communication) 통신을 위한 채널 특성을 모델링하였다. 간접 조명은 직사 조도가 없이 모든 광속이 천정 및 벽을 반사한 후에 실내 바닥 면에 고르게 도달하는 방식이며, 광원에서 출발한 광 입자(Photon)는 간접경로(NLOS : None Line of Sight)를 통하여 수신부(PD, Photodiode)에 도달한다. 실내 간접 조명 환경으로서 가로(6m), 세로(4m), 높이(2.2m) 크기의 방(room)을 가정하였으며, 4개의 LED(Light Emitting Diode) 간접 조명을 2m 높이에 위치하여 벽과 천정을 향하여 빛을 비추도록 하였다. 바닥으로부터 50cm 위에 위치한 PD에서 수신 전력의 크기와 지연 수신된 신호를 통하여 채널 특성을 추출하였다. 도출된 채널은 BPSK 기반 통신 시뮬레이션을 통해서 그 유효성을 입증하였다.

혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가 (Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments)

  • 신화영;김정태
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.