• Title/Summary/Keyword: Light Output

Search Result 902, Processing Time 0.031 seconds

Improvement of Light Extraction Efficiency of LED Packages Using an Enhanced Encapsulant Design

  • Choi, Hyun-Su;Park, Joon-Sik;Moon, Cheol-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.370-376
    • /
    • 2014
  • We optimized the design of the flat encapsulant of a light-emitting diode (LED) package to obtain higher light output power (LOP), both by experiment and simulation using three-dimensional ray-tracing software. In the experiment, the refractive index of the encapsulant was varied (1.41 and 1.53). In addition, double-layer structures with these refractive indices (1.41/1.53) were investigated by varying the shape of the interface between the two among flat, concave, and convex. The experiments showed that the LOP of the double-layer encapsulant with convex interface increased by 13.4% compared to the single-layer encapsulant with a refractive index 1.41, which was explained by the increase of the light extraction efficiency (LEE) in connection with the increase of the critical angle (${\theta}_c$) and the decrease of the Fresnel reflection.

Analysis for Light Load Regulation of LLC Converter using Bode Plot (보드 선도를 이용한 LLC 컨버터의 경 부하 레귤레이션 특징 분석)

  • Yeon, Cheol-O;Moon, Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.506-513
    • /
    • 2016
  • In general, LLC converters show great promise in applications that require high efficiency, especially under light load conditions. In particular, LLC converters feature wide gain capability with pulse-frequency modulation and zero voltage switching over entire load conditions. However, output voltage increases in light load conditions. In this study, Bode plot and impedance asymptotes analyses were conducted to obtain insights into the regulation characteristics of LLC converters under light load conditions. To improve the regulation characteristic of LLC converters, a new resonant tank with an additional capacitor is proposed. The design guideline for the proposed LLC converter is determined by the Bode plot and impedance asymptotes analyses. Therefore, the proposed LLC converter achieves the light load regulation while maintaining the advantages of typical LLC converters.

Simulation Study on the Optimization of Hybrid Light Guide Plates for Edge-lit Backlight Applications

  • Lee, Jeong-Ho;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.693-696
    • /
    • 2009
  • The ray-tracing technique was used to optimize the light guide plate for the purpose of improving the on-axis luminance on the edge-lit backlights. One-dimensional prisms and engraved V-shaped patterns were applied to the upper and the lower surfaces of the light guide plate, respectively. By optimizing the apex angles of these micro-structures, as well as the shape of the reverseprism film put over the light guide plate, highly-collimated light-output distribution could be obtained on the backlight, which may contribute to the development of mobile LCD's with low power consumption.

  • PDF

The polymerization rate and the degree of conversion of composite resins by different light sources

  • Ryoo, Joo-Hee;Kwon, Hyuk-Choon
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.565-566
    • /
    • 2003
  • The clinical performance of light polymerized composite resins is greatly influenced by the quality of the light curing unit used. Commonly used halogen light curing units(LCUs) have some specific drawbacks such as decreasing light output with time. To overcome this, the blue LED LCUs are newly developed and introduced. The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue LED LCUs compared with conventional halogen LCUs.(omitted)

  • PDF

Illumination Control in Visible Light Communication Using Transition Frequency Modulation (천이주파수 변조를 이용한 가시광통신의 조명제어)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.99-104
    • /
    • 2021
  • In this study, we utilized the duty factor of the transition frequency modulation (TFM) for the illumination control of the light emitting diode (LED) light in visible light communication (VLC). The average optical power is linearly proportional to the duty factor in TFM waveforms. We used the transition frequencies of Na=5 and Nb=1 for the high and the low bits, respectively, of the non-return-to-zero (NRZ) data in the VLC transmitter. A resistor and capacitor high-pass filter (HPF) was used in the VLC receiver to eliminate the 120 Hz optical noise from adjacent lighting lamps and the spikes at the HPF output were used to recover NRZ data from the TFM waveform. In experiments, the illumination of the LED light was controlled in the range of 25-90% of the constant-wave optical power by changing the duty factor of the TFM waveforms.

Experimental Demonstration of Long-reach 2×2 Multiple-Input Multiple-Output (MIMO) Visible Light Communications Using an Image Sensor Receiver (이미지 센서 수신부를 이용한 장거리 2×2 MIMO LED 무선 가시광 통신 실험)

  • Jeon, Jong-Bae;Kim, Sung-Man
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8B
    • /
    • pp.706-711
    • /
    • 2012
  • The current visible light communication (VLC) systems have a short transmission distance and a low data rate. To overcome this, we studied on the method of appling MIMO technology to VLC. However, it is difficult to apply the original MIMO technology used in RF frequency to wireless VLC. In VLC system, a lens can be used to separate the transmitted signals. And, if we use an image sensor as the receiver, MIMO technology can be applied to LED wireless visible light communication. In this paper, we report an experiment of $2{\times}2$ LED wireless visible light communication using a commercial image sensor receiver. We show the experimental demonstration with a transmission length of 10.5 m and a data rate of 200 bit/s.

Development Plan of a Human Model System for Educating Acupoint Location and Its Implementation (경혈 위치교육 평가지원시스템의 개발계획 수립과 제작)

  • Yeo, Sujung;Nam, Donghyun
    • Korean Journal of Acupuncture
    • /
    • v.36 no.1
    • /
    • pp.44-51
    • /
    • 2019
  • Objectives : Teaching the standardized acupuncture point locations and improving the accuracy of acupoint locations through objective evaluation is a very important part of Korean medicine education. The aim of this study is to develop a dummy system for evaluation and support of teaching acupoint location in meridian and acupoints classes and to introduce the developed system. Methods : We established a protocol for the development of the system. The protocol included definition of usage purpose, definition of its essential performance, and set of scope. The system compares the amount of light at the target acupoint with the amount of light at the other sites to determine whether the target acupoint is properly specificated. Results : A prototype of the system was built according to the protocol and consists of light emitter, dummy, control/operation, input part and output part. The light emitter projects laser beam passing through the skin of the dummy. Light sensors were attached inside the acupoints of the dummy. Three types of light sensors were selected depending on the location of the acupoints. The arithmetic, input, and output parts were constructed using Arduino and Raspberry pi boards. The developed system was applied in class. Conclusions : It is thought that the dummy system for evaluation and support of teaching acupoint location can be used as a training model in order to help teach standardized acupoint locations and objective evaluation.

Assessment of the radiant emittance of damaged/contaminated dental light-curing tips by spectrophotometric methods

  • Abdulrahman A. Balhaddad;Isadora Garcia;Fabricio Collares;Cristopher M. Felix;Nisha Ganesh;Qoot Alkabashi;Ward Massei;Howard Strassler;Mary Anne Melo
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.55.1-55.12
    • /
    • 2020
  • Objectives: This study investigated the effects of physically damaged and resin-contaminated tips on radiant emittance, comparing them with new undamaged, non-contaminated tips using 3 pieces of spectrophotometric laboratory equipment. Materials and Methods: Nine tips with damage and/or resin contaminants from actual clinical situations were compared with a new tip without damage or contamination (control group). The radiant emittance was recorded using 3 spectrophotometric methods: a laboratory-grade thermopile, a laboratory-grade integrating sphere, and a portable light collector (checkMARC). Results: A significant difference between the laboratory-grade thermopile and the laboratory-grade integrating sphere was found when the radiant emittance values of the control or damaged/contaminated tips were investigated (p < 0.05), but both methods were comparable to checkMARC (p > 0.05). Regardless of the method used to quantify the light output, the mean radiant emittance values of the damaged/contaminated tips were significantly lower than those of the control (p < 0.05). The beam profile of the damaged/contaminated tips was less homogeneous than that of the control. Conclusions: Damaged/contaminated tips can reduce the radiant emittance output and the homogeneity of the beam, which may affect the energy delivered to composite restorations. The checkMARC spectrophotometer device can be used in dental offices, as it provided values close to those produced by a laboratory-grade integrated sphere spectrophotometer. Dentists should assess the radiant emittance of their light-curing units to ensure optimal curing in photoactivated, resin-based materials.

A CLINICAL STUDY ON THE MAINTENANCE OF LIGHT INTENSITY OF VISIBLE-LIGHT CURING MACHINES FOR THE POLYMERIZATION OF COMPOSITE RESINS (복합레진 중합용 가시광선 광중합기의 적정 광강도 유지를 위한 임상적 고찰)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.363-368
    • /
    • 2001
  • It is well known that numerous factors influence the light output of curing units, but many dentists are un aware that the output of their curing lights are inadequate. This study was conducted to evaluate the light in tensity of visible-light curing units in some private dental clinics and hospital dental clinics. In order to determine the maximum light intensity of the curing units, lamps, filters and fiber optic bundles, they were replaced with new ones and light intensity was remeasured. Light intensity was measured by employing a digital radiometer (EFOS model #8000, USA). Light intensity ranged in $29\sim866mW/cm^2$ (below $150mW/cm^2$ ; 17.8%, $150\sim300mW/cm^2$ : 46.6%, above $300mW/cm^2$ ; 35.6%). The replacement of the components increased the light intensity, with maximum increases of 94.8% for lamps, 82.3% for filters, 200.8% for fiber optics and 361.5% for all three parts. According to the manufacturer of radiometer, curing light is considered as unsuitable for use with a reading of above $300mW/cm^2$ by the radiometer. Applying these criteria to the present study, 64.4% of the curing units required repair or replacement. The results of this study indicated that the light intensities of the curing units used in dental practice were lower than optimum level.

  • PDF

A High-Efficiency, Auto Mode-Hop, Variable-Voltage, Ripple Control Buck Converter

  • Rokhsat-Yazdi, Ehsan;Afzali-Kusha, Ali;Pedram, Massoud
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.115-124
    • /
    • 2010
  • In this paper, a simple yet efficient auto mode-hop ripple control structure for buck converters with light load operation enhancement is proposed. The converter, which operates under a wide range of input and output voltages, makes use of a state-dependent hysteretic comparator. Depending on the output current, the converter automatically changes the operating mode. This improves the efficiency and reduces the output voltage ripple for a wide range of output currents for given input and output voltages. The sensitivity of the output voltage to the circuit elements is less than 14%, which is seven times lower than that for conventional converters. To assess the efficiency of the proposed converter, it is designed and implemented with commercially available components. The converter provides an output voltage in the range of 0.9V to 31V for load currents of up to 3A when the input voltage is in the range of 5V to 32V. Analytical design expressions which model the operation of the converter are also presented. This circuit can be implemented easily in a single chip with an external inductor and capacitor for both fixed and variable output voltage applications.