• 제목/요약/키워드: Light Load

검색결과 948건 처리시간 0.031초

50% 미만 부하조건에서의 3상 몰드변압기 진동 측정과 분석 (The vibration detection and analysis of 3-phase cast resin transformer in less than 50% load conditions)

  • 송길목;방선배;김종민;김영석;최명일
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.992-997
    • /
    • 2012
  • In this paper, we were analyzed the vibration characteristics of the three-phase cast resin transformer using less than 50% of load in the field. Most of the cast resin transformer is less than 50% in the domestic field is used for load conditions. Consisting of a solid insulator cast resin transformer is generating lots of noise and vibration. In addition, because it is affected by Joule 's heat is used in light load conditions. As a results, the transformer vibrations at frequencies below about from 200Hz to 500Hz were detected. Vibration velocity depends on the load variations were found. Load up to approximately 20-30% in most cases the vibration velocity was found at 4,000 ${\mu}m/s$ or less, 8,000 ${\mu}m/s$ or more. Vibration frequency at light load conditions were generated at the 120Hz, 240Hz, 360Hz and 480Hz. At the load condition of from 10% to 20%, vibration velocity is higher than another. Most of the vibration velocity were identified at the 1,000 ${\mu}m/s$ or less. Using the vibration frequency and velocity measurements data, the load on the cast resin transformer analyzed the correlation of the burden. Therefore, this data could be found in the vibration characteristics of the light-load conditions. If the field measurements using the data perform diagnostics on the transformer, it's expected to be very effective.

차대 동력계에서의 디젤 차량의 매연 측정을 위한 여지 반사식 및 광투과식 측정법의 비교 연구 (A Comparative Study on the Measurement of Smoke from Diesel Vehicle on Chassis-dynamometer using Reflection Photo and Light Extinction Method)

  • 김주청;이충훈
    • 한국안전학회지
    • /
    • 제22권6호
    • /
    • pp.13-19
    • /
    • 2007
  • Diesel car's smoke measurement equipment and method were investigated based on the exhaust gas regulations. Reflection photo method and light extinction method for measuring smoke were compared under conditions of both no load mode and Lug-down 3 mode. Free acceleration mode at no load condition was used for regular inspection of diesel car, and Lug-down 3 mode was used for fine inspection of the diesel car. A correlation between no load mode and Lug-down 3 mode was investigated in this research. The smoke measured with reflection photo method was 1.5${\sim}$2 times higher than that of light extinction method The correlation coefficient between reflection photo method and light extinction method for measuring smoke was 0.83, which shows comparatively high correlation between the two methods for measuring smoke in diesel engines.

작은 축력을 받는 H형강 기둥의 베이스플레이트 거동과 설계 (Behavior and Design of H-Section Steel Column Base Plates for Light Concentric Load)

  • 심기철;김은화;김원기
    • 한국강구조학회 논문집
    • /
    • 제16권4호통권71호
    • /
    • pp.453-461
    • /
    • 2004
  • 국내에서는 아직 철골구조의 베이스플레이트에 대한 설계기준이 작성되어 있지 않으므로 외국 기준 및 자료들을 근거로 중심축하중을 받는 H형강 기둥아래의 베이스플레이트에 대한 ASD 설계식을 제안하고자 한다. 또한 제안된 설계식과 하중을 변화시키며 설계한 예제를 비교한 결과, 보통의 축력을 받을 때에는 플레이트 면이 위험단면 $0.95d{\times}0.8b_f$인 사각형 길이면에 고정시킨 외측캔틸레버 보와 H형강 기둥 내부3변고정 플레이트로 가정한 것 중 위험한 쪽으로 설계한다. 그리고 적은 축력을 받을 때에는 베이스플레이트의 위험단면 및 지압면은 웨브에 면한 기둥 플랜지 사이의 캔틸레버로 설계한다.

Link Quality Estimation in Static Wireless Networks with High Traffic Load

  • Tran, Anh Tai;Mai, Dinh Duong;Kim, Myung Kyun
    • Journal of Communications and Networks
    • /
    • 제17권4호
    • /
    • pp.370-383
    • /
    • 2015
  • Effective link quality estimation is a vital issue for reliable routing in wireless networks. This paper studies the performance of expected transmission count (ETX) under different traffic loads. Although ETX shows good performance under light load, its performance gets significantly worse when the traffic load is high. A broadcast packet storm due to new route discoveries severely affects the link ETX values under high traffic load, which makes it difficult to find a good path. This paper presents the design and implementation of a variation of ETX called high load - ETX (HETX), which reduces the impact of route request broadcast packets to link metric values under high load. We also propose a reliable routing protocol using link quality metrics, which is called link quality distance vector (LQDV). We conducted the evaluation of the performance of three metrics - HETX, ETX and minimum hop-count. The simulation results show that HETX improves the average route throughput by up to 25% over ETX under high traffic load. Minimum hop-count has poor performance compared with both HETX and ETX at all of the different traffic loads. Under light load, HETX and ETX show the same performance.

뜬바닥층의 하중조건에 따른 경량충격음 저감량 분석 (Analysis of the Reduction of Light-weight Imapct Noise for Load Condition of Floating Floor)

  • 김명준;이성호;양재훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.356-360
    • /
    • 2006
  • Recently, for the purpose of improving the isolation performance of impact noise, many resilient materials have been installed in a residential building. As one of the reduction method for improving the performance of light-weight impact noise, this study is focused on the load condition of floating layer over resilient material. We studied the correlation between the mass or load of the floating layer and the reduction of light-weight impact noise by experiments in reverberation chamber for testing the impact noise. The results show that the reduction of impact noise is improved by increasing the mass per unit area of floating layer until about $140kg/m^2$. But the reduction is not obvious by adding extra mass on the floating layer.

  • PDF

비배수 전단강도에 따른 압입식 경량강재앵커블록의 거동 특성 (Characteristics of Behavior of Pressurized light-weight steel Anchor according to undrained shear strength)

  • 허열;안광국;박경수;이용준;강홍식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.219-224
    • /
    • 2009
  • In this study, the characteristics of pullout behavior of Pressurized light-weight steel Anchor was investigated through centrifuge model tests considering pull-out angle $0^{\circ}$ with changing undrained shearstrength(0~1, 2~4, 5~7kPa) of clay. According to the results of tests, the yield pullout load of clay ground was gradually increased up to 30% as undrained shear strength was increased. Therefore, it was known that the yield pullout load was affected by increasing the undrained shear strength, in addition, the pattern of behavior was not changed.

  • PDF

경충돌안전장치 설계를 위한 기초연구 (The basic study on the design of the Light Collision Safety Device)

  • 최원목;정현승;유원희;구정서;권태수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.238-244
    • /
    • 2006
  • The Light Collision Safety Device is used to protect the important part of trains and passengers at the low velocity accidents. The Light Collision Safety Device comprises mainly tension bolts, shear bolts and an energy absorber. The work mechanism of this device is that first, the tension bolts break at designed collapse load and second, the energy absorber absorb rest collision energy. In this paper, the tension bolt characteristics were validated by the simple tension test using the FEM(Finite Element Method) and the characteristic of the two types of energy absorber were compared by using the load-displacement curves and absorbed energy. Last, in order to determine integrated load-displacement curve of tension bolts and the energy absorber, the unified analysis was conducted by using the FEM.

  • PDF

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.

Design of a Variable Inductor Using MR Fluid Gap for Wide Load Range Efficiency Improvement of a Soft-Switching High-Power Density Bidirectional Dc-Dc Converter

  • Ahmed, Furqan;Kim, Su-Han;Cha, Honnyong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.184-185
    • /
    • 2013
  • In this paper, design of a variable inductor using MR Fluid Gap is proposed for wide load range efficiency improvement of a bidirectional DC-DC converter. As compared to conventional constant value inductor designed to have negative current for ZVS at heavy load but suffers high losses at light load due to its small inductance, the proposed variable inductor not only have small inductance at high current for ZVS but also it has large inductance at low current to decrease light load losses.

  • PDF

BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구 (A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System)

  • 이충식;이응직;이철구
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.