• Title/Summary/Keyword: Light Emission Image

Search Result 50, Processing Time 0.02 seconds

Flow Visualization by Light Emission in the Post-chamber of Hybrid Rocket (광도측정에 의한 하이브리드 로켓 후연소실의 유동 가시화)

  • Park, Kyung-su;Choi, Go Eun;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.8
    • /
    • pp.677-683
    • /
    • 2015
  • Hybrid rocket combustion displays low frequency instability(LFI, 10~30Hz) at a certain condition. Vortex shedding in the post-chamber is suspected to cause the occurrence of LFI. This study focused on the visualization of flow image using light emissions from high temperature combustion gas. Results shows that combustion pressure oscillates at a frequency of about 18 Hz, which is in phase with oscillations of light emission. Since LFI is not a property of thermo-acoustic instability, this result suggested there exists a physical coupling of pressure fluctuations with light emissions proportional to chemical reaction. Also POD analysis shows that dominant symmetric spatial modes in the stable combustion shift suddenly into asymmetric spatial pattern with the appearance of LFI. Especially, the appearance of mode 3 is a typical change of flow dynamics in unstable combustion representing a rotational fluid motions associated with vortex shedding.

DEVELOPMENT OF WIDE-FIELD IMAGING CAMERA FOR ZODIACAL LIGHT OBSERVATION

  • KWON S. M.;HONG S. S.;SHIN K. J.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.179-184
    • /
    • 2004
  • We have developed a wide-field imaging camera system, called WICZO, to monitor light of the night sky over extended period. Such monitoring is necessary for studying the morphology of interplanetary dust cloud and also the time and spatial variations of airglow emission. The system consists of an electric cooler a CCD camera with $60\%$ quantum efficiency at 500nm, and a fish-eye lens with $180^{\circ}$ field of view. Wide field imaging is highly desired in light of the night sky observations in general, because the zodiacal light and the airglow emission extend over the entire sky. This paper illustrates the design of WICZO, reports the result of its laboratory performance test, and presents the first night sky image, which was taken, under collaboration with Byulmaro Observatory, on top of Mt. Bongrae at Yongweol in January, 2004.

Evaluation of Relative Emission of Image Plate by Using Relative Sensitivity in Computed Radiography System (컴퓨터 방사선영상시스템에서 비감도를 이용한 영상판의 상대적 발광량 평가)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.355-361
    • /
    • 2014
  • The aim of the present study was to evaluate a relative emission of image plate (IP) in computed radiography (CR) system by using relative sensitivity in film/screen methods. The characteristic curve was obtained by using the uniform aluminum 11-step wedge penetrometer. X-ray exposure factors on radiographic digital image were 50 kVp, 10 mAs. We adjusted zero of all parameter of algorithms (MUSICA) so proximate to raw data and applied to 200 of exposure class. Modeling on relative emission of IP are used IP without fading time and IP after 4 hours, 8 hours, 12 hours, 24 hours in the respective storage after X-ray exposure. The results of this study showed that the sensitivity point density at the measuring of relative sensitivity in CR was suited pixel values of the 2000 easy to relatively measure the characteristic curve and when relative sensitivity is decreased, the amount of light emitted from the image signal for generating was also decreased. In conclusion, the proposed method of measurement of relative sensitivity can be utilized to evaluate the quantity of relative emission of IP in CR system.

Design of Small-sized Scintillation Pixel Detector with a Light Guide made of the Same Material as the Scintillation Pixel (섬광 픽셀과 동일한 물질로 광가이드를 적용한 매우 작은 섬광 픽셀 검출기 설계)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.523-529
    • /
    • 2023
  • In order to achieve excellent spatial resolution, very small scintillation pixels are used in detectors of positron emission tomography for small animals. However, by using these very small scintillation pixels, scintillation pixels at the edge of the array may overlap in a flood image. To solve this problem, a light guide capable of changing the distribution of light was used. Depending on the material of the light guide, the light spreading tendency is different, and accordingly, the presence or absence of overlapping is different depending on the material of the light guide used. In this study, instead of the conventional glass light guide, a detector using the same material as the scintillation pixel was designed. A scintillator light guide has a higher refractive index than a glass light guide, so the light spread is different. Flood images were acquired to evaluate the degree of separation of the scintillation pixels at the edge of the detector using the two light guides. The degree of separation was evaluated by calculating the distance between the center and the spatial resolution of the image of two scintillation pixels at the edge of the obtained flood image. As a result, when the scintillator light guide was used, better spatial resolution was shown, and the distance between centers of scintillation pixels was wider. When a detector is constructed using a scintillator light guide instead of a conventional glass light guide, it is possible to use a smaller scintillation pixel, thereby securing better spatial resolution.

Image Acquisition Study of Maximal Scintillation Pixel Array using Light Guide (광가이드를 사용한 최대 섬광 픽셀 배열의 영상 획득 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.249-255
    • /
    • 2022
  • Positron emission tomography for small animals has very high spatial resolution for imaging very small organs. To achieve good spatial resolution, the system must be constructed using very small scintillation pixels. When a detector is constructed using very small scintillation pixels, the size of the applicable array varies depending on the photosensor pixel. In a previous study, a study was conducted to find the maximum scintillation pixel arrangement according to the size of the photosensor. In this study, a detector with a light guide was designed to configure the detector using a more extended array of scintillation pixels, and try to find the maximum arrangement in which all scintillation pixels are imaged. The detector was designed using DETECT2000, which can simulate a detector made of a scintillator. Simulations were performed by configuring the detectors from an 11 × 11 scintillation pixel array to a 16 × 16 array. After obtaining a flood image by collecting the light generated from the scintillation pixel with a photosensor, the largest arrangement without overlap was found through image analysis. As a result, the largest arrangement in which all scintillation pixels could be distinguished without overlapping was a 15 × 15 arrangement.

A study on Technical Development a Trend of Digital Image Information (디지털 영상정보의 기술 발전 동향 연구)

  • Kim, Soo-Yong;Jee, Suk-Kun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.755-760
    • /
    • 2008
  • 영상 Display의 시장 동향과 기술 동향에 대하여 기술하였다. 영상 Display 로서는 그밖에 유기 EL(Electroluminescence), FED(Filed Emission Display) 등이 있고 차세대 Display도 개발이 진행되고 있다. 양자 모두 스스로 발광하는 형태를 취하기 위해서는 Back Light가 필요하지 않고, 박형과, 넓은 시야각, 또한 응답 속도가 빠르고 때문에 액정 Display 보다 유리하리라 판단된다.

  • PDF

Optical Gain Measuring System in the Laser Discharge using Feedback Light (귀환광을 이용한 레이저방전내의 광이득 측정시스템)

  • Choi, Sang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.9-14
    • /
    • 2011
  • A spectroscopic measuring system was developed in order to determine optical gain of gas laser discharge for any optical transitions between 190[nm] and 800[nm] without laser resonator. With an image optical system and a feedback optical system emission light of laser discharge are entered in a monochromator and received at a photomultiplier. Subsequently optical gain and line intensity are measured.

SMALL-SCALE STRUCTURE OF THE ZODIACAL DUST CLOUD OBSERVED IN FAR-INFRARED WITH AKARI

  • Ootsubo, Takafumi;Doi, Yasuo;Takita, Satoshi;Matsuura, Shuji;Kawada, Mitsunobu;Nakagawa, Takao;Arimatsu, Ko;Tanaka, Masahiro;Kondo, Toru;Ishihara, Daisuke;Usui, Fumihiko;Hattori, Makoto
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.63-65
    • /
    • 2017
  • The zodiacal light emission is the thermal emission from the interplanetary dust and the dominant diffuse radiation in the mid- to far-infrared wavelength region. Even in the far-infrared, the contribution of the zodiacal emission is not negligible at the region near the ecliptic plane. The AKARI far-infrared all-sky survey covered 97% of the whole sky in four photometric bands with band central wavelengths of 65, 90, 140, and $160{\mu}m$. AKARI detected the small-scale structure of the zodiacal dust cloud, such as the asteroidal dust bands and the circumsolar ring, in far-infrared wavelength region. Although the most part of the zodiacal light structure in the AKARI far-infrared all-sky image can be well reproduced with the DIRBE zodiacal light model, there are discrepancies in the small-scale structures. In particular, the intensity and the ecliptic latitude of the peak position of the asteroidal dust bands cannot be reproduced precisely with the DIRBE models. The AKARI observational data during more than one year has advantages over the 10-month DIRBE data in modeling the full-sky zodiacal dust cloud. The resulting small-scale zodiacal light structure template has been used to subtract the zodiacal light from the AKARI all-sky maps.

White Electroluminescent Device by ZnS: Mn, Cu, Cl Phosphors

  • Kim, Jong-Su;Park, Je-Hong;Lee, Sung-Hun;Kim, Gwang-Chul;Kwon, Ae-Kyung;Park, Hong-Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.3 s.16
    • /
    • pp.1-4
    • /
    • 2006
  • White-light-emitting ZnS:Mn, Cu, Cl phosphors with spherical shape and the size of $20\;{\mu}m$ are successfully synthesized. They have the double phases of cubic and hexagonal structures. They are applied to electroluminescent (EL) devices by silk screen method with the following structure: $electrode/BaTiO_3$ insulator layer ($50{\sim}60\;{\mu}m$)/ ZnS:Mn, Cu, Cl phosphor layer ($30{\sim}50\;{\mu}m$)/ITO glass. The EL devices are driven with the voltage of 100 V and the frequency of 400 Hz. The EL devices show the three emission peaks. The blue and green emission bands are originated from $CICu^{2+}$ transition and $ClCu^+$ transition, respectively. The yellow emission band results from $^4T^6A$ transition of $Mn^{2+}$ ion. As an increase of Cu concentrations, the blue and green emission intensities decrease whereas the yellow emission intensity increases; the quality becomes warm white. It is due to the energy transfer from the blue and green bands to the yellow band.

  • PDF

Two Layer DOI Detector Design for PET using Multiple Light Guides for Designing Light Distribution (다수의 광가이드를 통한 빛 분포 설계로 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.703-708
    • /
    • 2022
  • A detector module measuring the depth of interaction(DOI) was designed to improve the spatial resolution of positron emission tomography(PET). The scintillation pixel array consists of two layers, and a light guide is inserted between the layers to make the light generated through the gamma-ray event different for each layer. There are four light guides, and one light guide is designed to be coupled to a 2 × 2 array of scintillation pixels. The light generated from the top layer is moved to the photosensor with a wider distribution through the light guide, and the light generated from the bottom layer is incident on the photosensor with a narrower distribution than the top layer. When a flood image is reconstructed based on the signals obtained from the photosensor by different distributions, scintillation pixels are imaged at different positions for each layer. To verify this, a DETECT2000 simulation tool that simulates the behavior of light in a scintillator was used. By designing a scintillation pixel array, a detector consisting of a light guide and a photosensor, a gamma ray event was generated in all scintillation pixels to obtain a flood imgae. As a result, it was confirmed that the top and bottom layers were imaged at different positions and completely separated. When this detector is applied to PET, it is considered that image quality can be improved through imporved spatial resolution.