• 제목/요약/키워드: Lifting techniques

검색결과 47건 처리시간 0.026초

Painful Boney Metastases

  • Smith, Howard S.;Mohsin, Intikhab
    • The Korean Journal of Pain
    • /
    • 제26권3호
    • /
    • pp.223-241
    • /
    • 2013
  • Boney metastasis may lead to terrible suffering from debilitating pain. The most likely malignancies that spread to bone are prostate, breast, and lung. Painful osseous metastases are typically associated with multiple episodes of breakthrough pain which may occur with activities of daily living, weight bearing, lifting, coughing, and sneezing. Almost half of these breakthrough pain episodes are rapid in onset and short in duration and 44% of episodes are unpredictable. Treatment strategies include: analgesic approaches with "triple opioid therapy", bisphosphonates, chemotherapeutic agents, hormonal therapy, interventional and surgical approaches, steroids, radiation (external beam radiation, radiopharmaceuticals), ablative techniques (radiofrequency ablation, cryoablation), and intrathecal analgesics.

Frequency of bone graft in implant surgery

  • Cha, Hyun-Suk;Kim, Ji-Wan;Hwang, Jong-Hyun;Ahn, Kang-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.19.1-19.4
    • /
    • 2016
  • Background: Implant surgery has become popular with the advance of surgical techniques such as sinus lifting, guided bone regeneration, and block bone graft. However, there were no data about the frequency of bone graft during implant surgery. The purpose of this study was to report the frequency and types of bone graft depending on dental implant patients' profile to complement the database regarding implant surgery. Methods: The implant operations had been performed from January 2006 to October 2014. The upper and lower jaws were divided into six sextants. A total of 792 sextants were included in this study. Patient information including sex, age, sites, bone graft, and types of bone were investigated. Results: A total of 1512 implants had been placed. Male and female sextants were 421 and 371, respectively (M:F = 1:0.88). Average age was 54.3 (ranging from 20 to 88 years old). Implants were placed in the posterior maxilla (322 sextants, 40.7 %), posterior mandible (286 sextants, 36.1 %), anterior maxilla (127 sextants, 16.1 %), and anterior mandible (57 sextants, 7.2 %). Bone graft was performed in 50.3 % of the sextants. Among the bone grafted sites, sinus lifting with lateral approach (22.1 %) and guided bone regeneration (22.7 %) were performed most frequently. Conclusions: Bone graft in implant surgery was necessary to augment defects. More than half of the sextants needed bone graft for implant installation.

레이어 법칙을 활용한 긴 머리형과 중간 머리형의 디자인 연구 (A Study on Layer's Method Applied Long & Middle Hair Design)

  • 박상국;서윤경
    • 한국생활과학회지
    • /
    • 제18권3호
    • /
    • pp.793-798
    • /
    • 2009
  • Hair cut is one of the best useful technical tool for hair styling. In this study using the rule of the layers of hair design, balanced for visual art, perceptual ability and form created by the principles of analysis and offer hair cuts and hair design of the representation of regions and even hair design as the basis of a student of Hair Beauty and all the people working in the field can create a variety of hair design puts the purpose to establish a basis. The result of this study can be outline as follows: First, the step line and the movement of the relationship between the law of the layers above and below the length of the same layer techniques, the same consists of a vertical cross-section of the overall round shape of the cut same layer is created and the appropriate volume and movement, the movement of low-layer round a little bit more feeling and expression is used when you want. High-layer used to want to move a lot of light and could see that. Second, the layer of the Law and over direction, lifting, section, the line control. weight control and analyzed by principle and the principle of the process of forming the written form was unknown. Third, hair design, the expansion of the expressive power of the law of the layers, and the section of the over direction depends on the presence of line control to express the length of the outline I had to, lifting the weight to adjust form controls, and the expression of Hair Design will be expanding the width. A hair designer, a layer style to create a zone he thought the law of the first layer formative area To further the reach will be a lot of research, leading up formative aspects of this research thesis do not have missing parts, or as a result of the Beauty of Hair Design and the width of a hair design education in the field can perform to help feed the reference materials that will be.

Adaptive and Robust Aeroelastic Control of Nonlinear Lifting Surfaces with Single/Multiple Control Surfaces: A Review

  • Wang, Z.;Behal, A.;Marzocca, P.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권4호
    • /
    • pp.285-302
    • /
    • 2010
  • Active aeroelastic control is an emerging technology aimed at providing solutions to structural systems that under the action of aerodynamic loads are prone to instability and catastrophic failures, and to oscillations that can yield structural failure by fatigue. The purpose of the aeroelastic control among others is to alleviate and even suppress the vibrations appearing in the flight vehicle subcritical flight regimes, to expand its flight envelope by increasing the flutter speed, and to enhance the post-flutter behavior usually characterized by the presence of limit cycle oscillations. Recently adaptive and robust control strategies have demonstrated their superiority to classical feedback strategies. This review paper discusses the latest development on the topic by the authors. First, the available control techniques with focus on adaptive control schemes are reviewed, then the attention is focused on the advanced single-input and multi-input multi-output adaptive feedback control strategies developed for lifting surfaces operating at subsonic and supersonic flight speeds. A number of concepts involving various adaptive control methodologies, as well as results obtained with such controls are presented. Emphasis is placed on theoretical and numerical results obtained with the various control strategies.

Granuloma Formation, a Rare Complication after PDO Threads Lifting, and Adjuvant Treatment Using Dual-Frequency Ultrasound (LDM®-MED)

  • Hong, Seok Won;Park, Eun Soo
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.35-38
    • /
    • 2019
  • Thread-lifting is a minimally invasive procedure that shows good results and fewer complications as compared with those results and complications of standard surgery. Many procedures and techniques have been developed to create a younger appearance of facial/neck skin for aging people, and the demand for an improved aesthetic appearance is increasing. Since the incidence of side effects is much less than that of non-absorbable threads, which can lead to complications such as foreign body reactions, polydioxanone (PDO) threads are predominantly used for face lift procedures. A 66-year-old woman presented to our clinic with inflamed palpable masses. She had undergone a face lift with absorbable threads in our clinic 5 months previously. Excisional biopsy was performed with the patient under local anesthesia. During the operation, any threads were not detected and there was both fibrotic scar tissue and granulomatous tissue. For effectively promoting healing and managing the scars, treatment with LDM®-MED was performed on the day after surgery. The treatment was performed according to the author's protocol. Although foreign body granuloma as a complication after using non-absorbable thread types have been previously reported, it is relatively rare to find this type of complication after using absorbable thread. In this report, we present a case in which a 66-year-old female with foreign body granuloma after undergoing a face lift using absorbable threads was treated with the application of dual-frequency ultrasound, which promoted wound healing.

침자 수기법 교육 시스템 개발 (Development of Acupuncture Manipulation Education System)

  • 임진웅;정원모;이인선;서윤정;류호선;류연희;채윤병
    • Journal of Acupuncture Research
    • /
    • 제31권4호
    • /
    • pp.11-19
    • /
    • 2014
  • Objectives : Acupuncture manipulation, a kind of sophisticated hand movements, has been considered a fundamental skill for acupuncture practice. In this study, we aimed to develop acupuncture manipulation education system(AMES) using visual feedback of acupuncture manipulation. We also investigated whether or not acupuncture practice-$na{\ddot{i}}ve$ students could enhance their acupuncture manipulation skills after AMES training. Methods : Using AMES and motion sensor, we visualized a time-series motion template(intended motion) and participant's own motion(actual motion) manipulating an acupuncture needle. Ten students were trained with complex lifting/thrusting techniques for 8 training trials. We compared the motion pattern error of the students between the first and the last trials. Results : In our pilot experiment, half of the participants showed significantly improved manipulation skills in complex lifting/thrusting techniques after training with AMES which is developed in this study, while the other half of the participants did not show significant improvements. Conclusions : The AMES could be useful in acupuncture-manipulation training for students. Our findings suggest that novice can improve sophisticated hand movement for acupuncture manipulation with sensorimotor learning using visual feedback.

펀측 상지에 적용된 고유수용성 신경근 촉진법이 반대측 하지의 근 활성도에 미치는 영향 (Effect of Proprioceptive Neuromuscular Facilitation Applied to the Unilateral Upper Extremity on the Muscle Activation of Contralateral Lower Extremity)

  • 김경환;박지원;배성수
    • PNF and Movement
    • /
    • 제4권1호
    • /
    • pp.9-18
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effect of Proprioceptive Neuromuscular Facilitation (PNF) applied to the unilateral upper extremity on the muscle activation of contralateral lower extremity. Twenty-two healthy subjects (mean age of 23.7 years) participated in this study. Method : PNF patterns applied on the unilateral upper extremity in all subjects were the flexion/abduction/external rotation and lifting pattern. The hold and appoximation techniques for the irradiation were applied to end range of both patterns. Muscle activations in four patterns were measured in vastus medialis, tibialis anterior, rectus femoris, and gastrocnemius medial muscles of contralateral lower extremity using surface EMG system. Each EMG value in individual muscle was normalized for maximal voluntary contraction. The data were analyzed by one factor analysis of variance with repeated measure test. Result : There were significant differences in the between-subject effect (muscles) and within-subject effect (patterns) in comparison of muscle activation by application of PNF patterns (p<.05). The irradiation led to higher activation in the flexion/abduction/external rotation pattern than that of lifting pattern in all muscles (p<.05). The approximation techniques revealed more activations than these of hold technique in all muscles (p<.05). Conclusion : These results suggest that the application of PNF patterns to the unilateral upper extremity affect on the muscle activation of contralateral lower extremity and increase according to the intensity of resistance. This mechanism of contralateral effect might provide a help to the development of treatment method for the affected side and functional improvement for the patients who have damages of central nervous system or musculoskeletal problems by orthopedic injury.

  • PDF

A Multicenter Noncomparative Clinical Study on Midface Rejuvenation Using a Nonabsorbable Polypropylene Mesh: Evaluation of Efficacy and Safety

  • Pak, Chang Sik;Chang, Lan Sook;Lee, Hobin;Jeong, Jae Hoon;Jeong, Jinwook;Yoon, Eul-Sik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.572-579
    • /
    • 2015
  • Background Facial rejuvenation can be achieved using a variety of techniques. Since minimally invasive procedures for face lifting have become popular because of their convenience and short operating time, numerous minimally invasive surgical procedures have been developed. In this study, a nonabsorbable polypropylene mesh is introduced as a new face lifting instrument, with the nasolabial fold as the main target area. In this paper, we report the efficacy and safety of a polypropylene mesh in midface rejuvenation. Methods Thirty-three subjects with moderate-to-severe nasolabial folds were enrolled from two medical institutions for a noncomparative single-sample study. A mesh was inserted above the superficial muscular aponeurotic system layer, reaching the nasolabial folds through a temporal scalp incision. After 3 weeks, the temporal end of the mesh was pulled to provide a lifting effect. Then, the mesh was fixed to the deep temporal fascia using nonabsorbable sutures. To evaluate efficacy, we compared the scores on the Wrinkle Severity Rating Scale and a visual analog scale for patient satisfaction between the baseline and 7 weeks postoperatively. In addition, we evaluated safety based on the incidence of adverse events. Results The treatment was deemed effective at improving wrinkles in 23 of 28 cases, and patient satisfaction improved significantly during the study period. There were seven cases of skin or subcutaneous tissue complications, including edema and erythema, but there were no suspected serious adverse events. Conclusions Face lifting using a nonabsorbable mesh can improve nasolabial folds without serious adverse effects. Thus, this technique is safe and effective for midface rejuvenation.

불량한 치조제에서의 임플랜트 시술증례 (IMPLANT REHABILITATION IN THE UNFAVORABLE ALVEOLAR RIDGE)

  • 박재범;안상헌;정수일;조병완;안재진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권1호
    • /
    • pp.35-44
    • /
    • 1997
  • The most critical factor in determining which type of implant to be used would be the available bone of the patient. Usually a minimum of 5mm in the bone width and 8mm in the bone height is necessary to ensure primary implant stability and maintain the integrity of bone contact surface. Placement of implant is limited by the several anatomic strutures such as maxillary sinus, floor of the nose, inferior alveolar neurovascular bundle and nasopalatine foramen, etc. When severe resorption of alveolar ridge is encountered, implant placement would be a problematic procedure. A number of techniques to improve the poor anatomic situations have been proposed. This article reports 4 cases of patients using surgical procedures such as blade implant technique, cortical split technique in the anterior maxillary area, sinus lifting and lateral repositioning of inferior alveolar nerve, We treated dental implant candidates with unfavorable alveolar ridge utilizing various surgical techniques, resulted in successful rehabilitation of edentulous ridge.

  • PDF

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.