• Title/Summary/Keyword: Life Signal

Search Result 1,156, Processing Time 0.027 seconds

Tool Life Monitoring using AE Signal in Gear Shaping (기어가공식 AE 신호를 이용한 공구수명의 감시)

  • 최성필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.130-134
    • /
    • 1996
  • The characteristics of AE(Acoustic Emission) signal is related to cutting conditio, tool material, and tool geometry in metal cutting. The relation between AE signal and tool life was investigated experimentally. Experiment is carried out by gear shaping and SCM 420 workpiece. AE RMS voltage were increased according totool wear. It is suggested that maximum value of AE RMS voltage is an effective parameter to monitor tool life.

  • PDF

Comparison of Alpha-Factor Preprosequence and a Classical Mammalian Signal Peptide for Secretion of Recombinant Xylanase xynB from Yeast Pichia pastoris

  • He, Zuyong;Huang, Yuankai;Qin, Yufeng;Liu, Zhiguo;Mo, Delin;Cong, Peiqing;Chen, Yaosheng
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.4
    • /
    • pp.479-483
    • /
    • 2012
  • The secretory efficiency of recombinant xylanase xynB from yeast Pichia pastoris between the ${\alpha}$-factor preprosequence and a classical mammalian signal peptide derived from bovine ${\beta}$-casein was compared. The results showed that although the bovine ${\beta}$-casein signal peptide could direct high-level secretion of recombinant xylanase, it was relatively less efficient than the ${\alpha}$-factor preprosequence. In contrast, the bovine ${\beta}$-casein signal peptide caused remarkably more recombinant xylanase trapped intracellularly. Real-time RT-PCR analysis indicated that the difference in the secretory level between the two signal sequences was not due to the difference in the transcriptional efficiency.

A Study on the Monitoring Technique in Tool Failure and Tool Life by AE Method (AE법에 의한 공구손상 및 수명의 감시기술에 관한 연구)

  • Han, Eung-Kyo;Kim, Ki-Choong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.2 no.1
    • /
    • pp.62-71
    • /
    • 1985
  • This is a study on the monitoring technique in tool failure and tool life by AE method. The relation between amplitude level of AE signal and flank wear width was studied by experiments. The relation between amplitude level of AE signal and tool life was also studied. As the result, it was observed that amplitude level of AE signal was only affected by cutting velocity. Amplitude level of AE signal was directly proportional to flank wear width and the increasing rate was related to cutting velocity. So, the relation between amplitude level of AE signal and tool life was represented as follow: $CT^n$ = $AE_{rms}$ where, n=0.35 C=9.5*$10^{-2}$

  • PDF

Identifiable life vest signal generator in case of marine accident (해양사고 시 식별 가능한 구명조끼용 신호발생 장치)

  • Bang, Gul-Won
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.317-322
    • /
    • 2022
  • In general, life jackets are worn by people in critical situations on the water to rise to the surface without falling into water, and life jackets simply serve to prevent sinking, but do not actively help rescue disaster areas in critical situations early. In order to solve this problem, a device that automatically generates a distress signal in an emergency situation was developed. When the survivor is in hand for a while, the distress signal generator is automatically separated from the life jacket, allowing information such as location values and other information to be transmitted wirelessly and a rescue signal using LED light. As a result of the experiment, when submerged in water, the life jacket and the distress signal generator were automatically separated, and the result of wireless transmission of the coordinate value of the location received by the GPS was confirmed. By using this, the location of the distress or missing person can be identified, which can be quickly replaced in case of an emergency

Comparison of the Sensitivity of Type I Signal Peptidase Assays

  • Sung, Meesook
    • Journal of Life Science
    • /
    • v.11 no.2
    • /
    • pp.94-98
    • /
    • 2001
  • Type I signal peptidase cleaves the signal sequence from the amino terminus of membrane and secreted proteins afters these protein insert across the membrane. This enzyme serves as a potential target for the development of novel antibacterial agents due to its unique physiological and biochemical properties. Despite considerable research, the signal peptidase assay still remains improvement to provide further understanding of the mechanism and high-throughput inhibitor screening of this enzyme. In this paper, three known signal peptidase assays are tested with an E. coli D276A mutant signal peptidase to distinguish the sensitivity of each assays. In vitro assay using the procoat synthesized by in vitro transcription translation shows that the D276A signal peptidase I was inactive while in vivo processing of pro-OmpA expressed in the temperature-sensitive E. coli strain IT41 as well as in vitro assay using pro-OmpA nuclease A substrate show that D276A signal peptidase I has activity like wild-type signal peptidase. These results suggest that in vitro assay using the pro-OmpA nuclease A and in vivo pro-OmpA processing assay are more sensitive monitors than in vitro assay using the pro-coat. In conculsion, caution should be used when interpreting the in vitro results using the procoat.

  • PDF

Noninvasive Life Signal Detecting Systems and Their Analyses

  • Park, Jung-Min;Park, Dong-Hyuk;Park, Seong-Ook
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.45-49
    • /
    • 2003
  • Wireless life signal detecting system is implemented with using the mechanism of Doppler Effect. This system can measure the respiration and heart rates with the periodic movement of skin and muscle near the heart. The system is consisted of antenna, RF transmitter, receiver, and display part. We did use two operating frequencies at 1.9 ㎓ and 10 ㎓. Firstly, the link budget about detecting system is analyzed and the signal detected from the system is compared with electrocardiogram(ECG) of monitor which is using for patient monitoring in hospital. Secondly, the detection of vital sign is also performed according to the different distances, and including behind the wall.

Smart Radar System for Life Pattern Recognition (생활패턴 인지가 가능한 스마트 레이더 시스템)

  • Sang-Joong Jung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.91-96
    • /
    • 2022
  • At the current camera-based technology level, sensor-based basic life pattern recognition technology has to suffer inconvenience to obtain accurate data, and commercial band products are difficult to collect accurate data, and cannot take into account the motive, cause, and psychological effect of behavior. the current situation. In this paper, radar technology for life pattern recognition is a technology that measures the distance, speed, and angle with an object by transmitting a waveform designed to detect nearby people or objects in daily life and processing the reflected received signal. It was designed to supplement issues such as privacy protection in the existing image-based service by applying it. For the implementation of the proposed system, based on TI IWR1642 chip, RF chipset control for 60GHz band millimeter wave FMCW transmission/reception, module development for distance/speed/angle detection, and technology including signal processing software were implemented. It is expected that analysis of individual life patterns will be possible by calculating self-management and behavior sequences by extracting personalized life patterns through quantitative analysis of life patterns as meta-analysis of living information in security and safe guards application.

Evaluation of CDMA Network Based Wireless 3 Channel ECG Monitoring System (CDMA망 기반 3채널 심전도 모니터링 시스템의 평가)

  • Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.295-301
    • /
    • 2008
  • A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.

Condition Diagnosis of Air-conditioner Compressor by Waveform Analysis of AE Raw Signal (AE 원신호 파형분석에 의한 에어컨 컴프레서의 상태 진단)

  • 이감규;강익수;강명창;김정석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.125-129
    • /
    • 2004
  • For the diagnosis of compressor abnormal condition in air-conditioner, AE signal which is derived from wear condition, compressed air and assembly error is analyzed experimentally. The burst and continuous type AE signal occurred by metal contact and compressed air and AE raw signal of compressors were directly acquired in production line. After extracting samples according to waveforms, Early Life Test(ELT) is conducted and classified to normal and abnormal waveform. The efficient parameters of waveform pattern are investigated in time and frequency domain and the diagnosis algorithm of air-conditioner by Neural Network estimation is suggested.