A Study on the Measurement and Investigation of Air Quality in a University Library (대학도서관 실내 공기질 측정 및 조사 연구)

  • Lee, Jae-Won
    • Journal of Korean Library and Information Science Society
    • /
    • v.50 no.4
    • /
    • pp.635-658
    • /
    • 2019
  • In this study, the harmful factors measured in S university's central library were divided into ① air harmful substance ② biological harmful factors ③ carbon monoxide, carbon dioxide, and nitrogen dioxide concentration, measured and analyzed compared to the relevant criteria. The analysis showed that the harmful substances in the air - fine dust, asbestos, volatile organic compounds and formaldehyde - were all lower than the relevant standards, and that biological harmful factors such as fungi in the air, gramophageal bacteria, and endotoxin were also found to have no particular problems. The concentration of carbon monoxide, carbon dioxide, and nitrogen dioxide in the air was also maintained without any unusual factors compared to the concentration in the ordinary atmosphere. However, the library is a multi-use facility that needs regular cleaning and ventilation to manage the environment.

Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator (산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화)

  • 김만구;권영진;정영림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.2
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

The Study On tile Distribution of Indoor Concentration of Microorganism in Commercial Building (다중이용 시설의 실내공기 미생물 오염실태에 관한 연구)

  • Choi, Sang-Gon;Hong, Jin-Kwan;Park, Kyung-Su
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.15-20
    • /
    • 2005
  • Recently, IAQ(indoor air quality) is one of the greatest problems in our modern societies. Although research for IAQ is made rapid progress but microorganism concentration is much to be desired. So we have examined a variety of department store, subway station, underground shopping center, kindergartens, library etc. where people complain about the indoor air quality. The microorganism concentration of indoor air was investigated in this study and the average of total microorganisms was measured. The experimental results show that the ministry of Environment recommendation value (800 $CFU/m^3$)is in need of revision in the naer future.

  • PDF

The Study On the Distribution of Indoor Concentration of Microorganism in Commercial Building (다중이용시설의 실내공기 미생물 오염실태에 관한 연구)

  • Park Kyung-Su;Choi Sang-Gon;Hong Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.620-626
    • /
    • 2006
  • Recently, indoor air quality (IAQ) is one of the greatest problems in our modern societies. Although research for IAQ is made rapid progress but IAQ problems concerning in door microorganism contamination is required to be studied still more. So we have investigated the indoor microorganism concentration of a variety of department store, subway station, underground shopping center, kindergartens, library where people complain about the in-door air quality. The experiment on microorganism concentration of indoor air was carried out and the average of total microorganisms was measured. Comparing the experimental results with existing foreign criterion, the experimental results show that the ministry of environment recommendation microorganism concentration value ($800 CFU/m^3$) is in need of revision in the near future.

Impact Assessment of Remodeling Works on Indoor Air Quality in a University Library Building (대학 도서관 건물 리모델링에 따른 실내공기질 영향 평가)

  • Baek, Sung-Ok;Park, Dae-Gwon;Park, Sun-Young;Lee, Yeo-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.876-887
    • /
    • 2006
  • Recently, there have been a large number of remodeling (or renovation) works in old buildings in urban areas. Compared to new buildings, environmental risk might be more significant in such buildings where remodeling works are going on, since some parts of the building may still be in service for people. This study was carried out to investigate the impacts of remodeling works on the indoor air quality (IAQ) of a large building (a 22 stories university library). Indoor air monitoring was conducted during and after the remodeling works every two weeks for a one year period, and target compounds included BTEX, styrene, TVOC, carbonyl compounds such as formaldehyde and acetaldehyde. $CO,\;CO_2,\;PM_{10}$, and $PM_{2.5}$. Overall, the IAQ appeared to be recovered within two months after the remodeling works. However, in some places, concentrations of formaldehyde, toluene, xylene. and ethylbenzene showed higher levels even after works than those during the works. The results indicate that painting, glues and office furnitures are major sources of aromatic VOCs and formaldehyde. Therefore, in order to decrease the concentrations of toxic VOCs, the use of environmental-friendly building materials is strongly recommended during the remodeling works. In addition, IAQ control and management scheme (for example, baking the inside of the building) should be taken into consideration before reopening the buildings.

Indoor Air Quality in Various Type of Public Facilities at Honam Province (호남지역의 다중이용시설별 실내공기질 실태 조사)

  • Seo, Byeong-Ryang;Jeong, Man-Ho;Jeon, Jun-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

The Distribution Characteristics of Carbon Dioxide in Indoor School Spaces (교육시설 실내공간의 이산화탄소 농도분포 특성 연구)

  • Cho, Young-Min;Lee, Ji-Yun;Kwon, Soon-Bark;Park, Duck-Shin;Park, Jae-Hyoung;Cho, Ki-Chul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.117-125
    • /
    • 2011
  • There are many studies reporting the average carbon dioxide levels in various indoor spaces. However, there have been a few studies showing how carbon dioxide concentration varied at many measurement points in one indoor space. In this study, the changes of indoor carbon dioxide concentration at classroom, library, and kindergarten were reported to find its carbon dioxide distribution change at various locations and altitudes. The maximum carbon dioxide concentration of the 3 sites were measured as 2,684, 2,295, and 1,526 ppm, respectively. These values exceeded the guideline concentration of 1,000 ppm for public places. The concentration of carbon dioxide was higher at upper area than lower area, and this is probably due to the rise of warm breathing air generated from students. In the upper area, the carbon dioxide concentration was higher at center area than four corners. However, in the lower area, the carbon dioxide concentration was higher at four corners than center area. Therefore, it could be concluded that the center of upper area is the best place for the installation of ventilation or carbon dioxide removal system.

Users' Satisfaction on the Dormitory of High School in Jeonju City (고등학교 기숙사 주거시설에 대한 사용자 만족도 - 개인공간 단위실을 중심으로 -)

  • An, Jin-Sook;Choi, Byung-Sook
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.93-101
    • /
    • 2007
  • This study was to find out users' satisfaction on the dormitory of high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows: 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 2.88, and their satisfaction of the technical factor was 2.71 that was the lowest score in them. And The functional factor was highly effected their satisfaction. 5) The space utility and the space size of functional factor, the soundproof, the heating/ventilation and the indoor quality of technical factor, and the privacy of behavior factor were highly correlative to their satisfaction of unit space.

Users' Satisfaction on the Dormitory of High School in Jeonju City (고등학교 기숙사 주거시설에 대한 사용자 만족도)

  • An, Jin-Sook;Choi, Byung-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.202-207
    • /
    • 2006
  • This study was to find out users' satisfaction on the dormitory high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows : 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 3.23, and the space utility and the space size of functional factor and the heating/ventilation of technical factor were highly effected their satisfaction.