• Title/Summary/Keyword: LiF:Mg,Cu,Si

Search Result 26, Processing Time 0.022 seconds

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Thermoluminescent Characteristics of Newly Developed LiF:Mg,Cu,Na,Si TL Detectors

  • Lee J. I.;Kim J. L.;Chang S. Y.
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • Recently, a new sintered pellet-type LiF:Mg,Cu,Na,Si TL detector which has a high sensitivity and good reusability, named KLT-300(KAERI LiF:Mg,Cu,Na,Si TL detector), was developed by the variation of the dopants concentrations and the parameters of the preparation procedure at KAERI (Korea Atomic Energy Research Institute). In this study, the thermoluminescent characteristics of the newly developed TL detectors were investigated. The sensitivity of the TL detector was compared with that of the TLD-100 by light integration. The dose linearity of the detector was tested from $10^{-6}$ Gy up to 30 Gy. The dose response was very linear up to 10 Gy and a sublinear response was observed at higher doses. The energy response of the detector was studied for photon energies from 20 keV to 662 keV. The result shows that a maximum response of 1.004 at 53 keV and a minimum response of 0.825 at 20 keV were observed. The reproducibility study for the TL detector was also carried out. The coefficients of variation for each detector separately did not exceed 0.016, and for all the 10 detectors collectively was 0.0054. Lower limit of detection for the detector was investigated at 70 nGy by the Harshaw 4500 TLD Reader and the residual signal of the TL detector was found to be $0.57\%$.

Preparation of Radiation Detector and Radiation Dosimetry - TSEE Charactristics of LiF ( Mg , Cu , Na , Si ) Phosphor - (방사선 검출기의 제작과 방사선 선량측정 - LIF ( Mg , Cu , Na , Si ) 형광체의 TSEE 특성 -)

  • 도시홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.4
    • /
    • pp.328-331
    • /
    • 1991
  • LiF(Mg,Cu,Na,Si) 형광체의 ${\gamma}$선과 $\beta$선에 대한 TSEE 특성을 조사하였다. 상(60)Co ${\gamma}$선에 대한 감도는 약 450 counts/mR이었고, 여러 가지 $\beta$선에 대한 TSEE 에너지 의존성은 $\beta$입자의 평균에너지 0.02MeV에서 0.8MeV 사이에서 $\pm$10%이었다. 그리고 제작된 형광체 앞면에 7mg.cm 상(-2)의 인체 등가물질을 두 면 입사 $\beta$입자의 에너지에 무관하게 피부 흡수 선량을 측정할 수 있었다.

  • PDF

Thermally Stimulated Exoelectron Emission from LiF(Mg,Cu,Na,Si) Phosphor (LiF(Mg,Cu,Na,Si)형광체의 열자극엑소전자방출)

  • Doh, Sih-Hong;Jeong, Jung-Hyun;Aoki, M.;Nishikawa, T.;Tamagawa, Y.;Isobe, M.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.11-15
    • /
    • 1994
  • The TSEE characteristics of LiF(Mg,Cu,Na,Si)phosphor for gamma and beta rays are described. The TSEE glow curve of this phosphor showed 5 peaks in the range from $20^{\circ}C$ to $400^{\circ}C$ and its main peak appeared at $240^{\circ}C$. The sensitivity of the phospor for $^{60}Co$ gamma rays was about 450counts/mR. TSEE energy dependence for various beta radiation was nearly constant (${\pm}10%$) in the mean beta particle energy range from 0.02MeV to 0.8MeV. The efficiency of TSEE of the phosphor for beta radiation was $(2{\sim}15){\times}10^{-3}$.

  • PDF