• Title/Summary/Keyword: Level of Deterioration

Search Result 521, Processing Time 0.025 seconds

Damage classification of concrete structures based on grey level co-occurrence matrix using Haar's discrete wavelet transform

  • Kabir, Shahid;Rivard, Patrice
    • Computers and Concrete
    • /
    • v.4 no.3
    • /
    • pp.243-257
    • /
    • 2007
  • A novel method for recognition, characterization, and quantification of deterioration in bridge components and laboratory concrete samples is presented in this paper. The proposed scheme is based on grey level co-occurrence matrix texture analysis using Haar's discrete wavelet transform on concrete imagery. Each image is described by a subset of band-filtered images containing wavelet coefficients, and then reconstructed images are employed in characterizing the texture, using grey level co-occurrence matrices, of the different types and degrees of damage: map-cracking, spalling and steel corrosion. A comparative study was conducted to evaluate the efficiency of the supervised maximum likelihood and unsupervised K-means classification techniques, in order to classify and quantify the deterioration and its extent. Experimental results show both methods are relatively effective in characterizing and quantifying damage; however, the supervised technique produced more accurate results, with overall classification accuracies ranging from 76.8% to 79.1%.

System Replacement Policy for A Partially Observable Markov Decision Process Model

  • Kim, Chang-Eun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 1990
  • The control of deterioration processes for which only incomplete state information is available is examined in this study. When the deterioration is governed by a Markov process, such processes are known as Partially Observable Markov Decision Processes (POMDP) which eliminate the assumption that the state or level of deterioration of the system is known exactly. This research investigates a two state partially observable Markov chain in which only deterioration can occur and for which the only actions possible are to replace or to leave alone. The goal of this research is to develop a new jump algorithm which has the potential for solving system problems dealing with continuous state space Markov chains.

  • PDF

Utility of Serum Procalcitonin for Diagnosis of Sepsis and Evaluation of Severity (혈청 프로칼시토닌(serum procalcitonin) 측정을 통한 패혈증 진단 및 중등도 평가의 유용성)

  • Park, Tae-Jin;Lim, Chae-Man;Koh, Youn-Suck;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • Background: Early recognition and treatment of sepsis would improve patients' outcome. But it is difficult to distinguish between sepsis and non-infectious conditions in the acute phase of clinical deterioration. We studied serum level of procalcitonin (PCT) as a method to diagnose and to evaluate sepsis. Methods: Between 1 March 2009 and 30 September 2009, 178 patients had their serum PCT tested during their clinical deterioration in the medical intensive care unit. These laboratories were evaluated, on a retrospective basis. We classified their clinical status as non-infection, local infection, sepsis, severe sepsis, and septic shock. Then, we compared their clinical status with level of PCT. Results: The number of clinical status is as follows: 18 non-infection, 33 local infection, 39 sepsis, 26 severe sepsis, and 62 septic shock patients. PCT level of non-septic group (non-infection and local infection) and septic group (sepsis, severe sepsis, septic shock) was $0.36{\pm}0.57$ ng/mL and $18.09{\pm}36.53$ ng/mL (p<0.001), respectively. Area under the curve for diagnosis of sepsis using cut-off value of PCT >0.5 ng/mL was 0.841 (p<0.001). Level of PCT as clinical status was statistically different between severe sepsis and septic shock ($^*severe$ sepsis; $4.53{\pm}6.15$ ng/mL, $^*septic$ shock $34.26{\pm}47.10$ ng/mL, $^*p$ <0.001). Conclusion: Level of PCT at clinical deterioration showed diagnostic power for septic condition. The level of PCT was statistically different between severe sepsis and septic shock.

Measurement of the Engine Oil Deterioration of the Diesel Vehicle Using the Engine Oil Level Gauge (엔진오일 레벨게이지를 이용한 디젤 엔진의 오일 열화특성 측정)

  • Kim, Man Jae;Sin, Tae Ho;Lee, Sang Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.60-65
    • /
    • 2017
  • We designed and fabricated the engine oil monitoring sensor to measure engine oil deterioration through increased vehicle mileage. Since the condition of the engine oil can be affected by the state of the vehicle and its operating conditions, it should be directly measured and determined in every vehicle. The fabricated sensor has an aluminum parallel capacitor structure that measures capacitance related with the dielectric constant, which is one of the indices of oil deterioration. The size of the capacitor is small enough that it could be easily adapted on the oil level gauge without introducing any change in the design. The fabricated device is installed in the diesel engine to measure the change in capacitance accurately as the vehicle moved from 0 km (new engine oil state) to 11,364 km. The results showed the maximum value at around 5,000 km, and the values plateaued as mileage increased, corresponding with the measurement result of the TAN (Total Acid Number). Based on the results, the condition of the oil must be monitored regularly though oil change is recommended once the vehicle has traveled the distance of around 10,000 km.

Estimation of Deterioration Assessment for Weighting Factors in Pipes of Water Supply Systems Using Analytic Hierarchy Process (계층적분석과정을 이용한 상수관로의 노후도 평가를 위한 항목별 가중치 산정)

  • Kim, Eung-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.15-21
    • /
    • 2008
  • The purpose of this study is to estimate deterioration assessment for weighting factors in pipe network for which each local selfgovernment takes rehabilitation and replacement work at present time. Deterioic hierarchy process(AHP), calculates the weighting factors. The appropriate marks matrix of sixteen deterioration factors are made for the precise decision standard of pipe condition through the result of this analysis. The marks matrix of sixteen deterioration factors can solve the complicated decision making problems of pipe rehabilitation workration factors in the pipe network might be influenced by local factors, such as province, location, or land use, in water supply systems. In this study, the sixteen deterioration factors are determined suitable for domestic situation based on the pipe deterioration factor data inside and outside of the country. Also, we select persons in charge of calculating the detail weighting factors and do survey about important level of each deterioration factors. Delphi method, a question survey method applying the analyts.

An experimental study on the effect of deterioration of drainage system on tunnel structures (배수시스템 수리기능저하가 터널구조물에 미치는 영향에 대한 실험적 연구)

  • Kwon, Oh-Yeob;Shin, Jong-Ho;Yang, Yu-Hong;Joo, Eun-Jung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.970-979
    • /
    • 2006
  • Construction of underground structure requires higher standard of planning and design specifications than in surface construction. However, high construction cost and difficult working environment limit design level and construction quality. One of the most sensitive factors to be considered are infiltration and external pore-water pressures. Development of pore-water pressure may accelerate leakage and cause deterioration of the lining. In this paper, the development of pore-water pressure and its potential effect on the linings are investigated using physical model tests. A simple physical equipment model with well-defined hydraulic boundary conditions was devised. The deterioration procedure was simulated by controlling both the permeability of filters and flowrate. Development of pore-water pressure was monitored on the lining using pore pressure measurement cells. Test results identified the mechanim of pore-water pressure development on the tunnel lining which is the effect of deterioration of drainage system. The laboratory tests were simulated using coupled numerical method, and shown that the deterioration mechanism can be reproduced using coupled numerical modelling method.

  • PDF

A Study on the Combined Deterioration of Concrete subjected to Freezing-Thawing and Chloride Attack (동해와 염해를 동시에 받는 콘크리트의 복합열화에 관한 연구)

  • Kim Eun-Kyum;Choi Sang-Deok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.225-228
    • /
    • 2005
  • This paper was accomplished for analyzing the reason of the above deterioration happened on the deck of concrete bridge. The bridge was constructed at 660m above the sea level having more freezing and snowing days. Therefore, it is placed on the particular condition sprinkling $CaCl_2$ enough for keeping up with moderate traffic condition. When it is considered to the former condition, the bridge can be assumed to potentialities for combined deterioration with freezing-thawing under sprinkling deicing chemical. Core specimens were gathered from the concrete deck for clearing the reason of the above deterioration exactly, and it is used for various tests for measuring the compressive strength, elastic modulus, content of $Cl^-$, freezing-thawing at the fresh and salt water. As a result of freezing-thawing test, the specimen at the fresh water has over 90$\%$ of durability factor, but another specimen at 1$\%$ of salt water has 0$\%$ of durability factor at 140 cycles of the freezing-thawing. The result means that frost damage is sccelerated at the salt water. Therefore, the deterioration of the concrete deck is estimated to be occured by combined effects of freezing-thawing and chloride ion attack.

  • PDF

A Study of the Sectionalizing for Pipe Deterioration Evaluation in Industrial Facilities (산업시설 배관 노후도 평가를 위한 배관 섹션화 방안 연구)

  • Min, Hyuk-Ki;Kim, Sang-Bum;Kim, Byung-Woo;Kim, Hyoung-Ki;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • In general, no particularly well-established standards have been in place so far, for the method of evaluating the deteriorated level of pipes and ducts of industrial facilities. For that reason, the evaluation depends upon various studies which are based on the analysis of the residual life, thickness thinning, closure rate, and scale thickness that measure a few specific positions of pipes. It also depends upon the expertise in business operation and the specific techniques conducted by the inspection companies and institutions. This research introduces the concept of measuring units per section and the selection method of measurement points per section. Furthermore, specific methodologies were developed to plan and analyze deterioration level of industrial pipes and ducts by engineers and managers using a section map. Consequently, applying the outcomes from this study to the plant equipment of the incineration facility resulted in saving 42% of the repairing and remodeling cost.

A Study on the Deterioration Progress of Railway Arresters (철도용 피뢰기의 열화진전에 관한 연구)

  • Kil Gyung-Suk;Han Ju-Seop;Han Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1393-1395
    • /
    • 2004
  • Arresters are the best protective device on electrical power systems against transient overvoltages generated by lightning and/or switching operation. Nonetheless, arresters will be deteriorated due to absorption of moisture in the environments of its use, repetition in the protective operation to overvoltages, and some defects at manufacturing. It is therefore important to estimate the electrical characteristic changes of ZnO blocks. In this paper, an accelerated deterioration test by a standard lightning impulse current was carried out to extract parameters needed for diagnosing arrester deterioration, and leakage current components were measured. Total energy applied to the ZnO blocks at each time is 1,050[J] in 8/20[${\mu}s$] impulse current. From the experimental results, we proposed electrical parameters and leakage current level to diagnose arrester soundness.

  • PDF

Decision Making of Improvement Priority by Deterioration Risk Assessment of Water Supply Infrastructures (물공급시설의 노후 위험도 평가를 통한 개선 우선순위 결정)

  • Chae, Soo-Kwon;Lee, Dae-Jong;Kim, Ju-Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.367-376
    • /
    • 2009
  • This paper proposes an application methodology of AHP(Analytic Hierarchy Process) based decision making theory for improvement priority by assessment of various risk factors affecting on deterioration of water supply systems, as major social infrastructure. AHP method is organized with three level of hierarchy which is introduced for multi-criteria decision making in this study. In the first level, assessment outputs are calculated by AHP for each affecting factor. In the second level, criteria are estimated by using assessment results with respect to structural and environmental factors. Consequently, ranking decision is performed in the third level. In order to present the effectiveness, a proposed method is compared with FCP(Fuzzy Composite Programming) for decision making. Since the results of the proposed method show better performance with consistent results, it can be applied as an efficient information for the determination for improvement priority of the study infrastructure.