• Title/Summary/Keyword: Level maintaining Device

Search Result 28, Processing Time 0.024 seconds

[ $H{\infty}$ ] Control of Level Maintaining Device (수평유지장치의 $H{\infty}$ 제어)

  • Oh, Young-Jin;Suh, Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.2
    • /
    • pp.77-84
    • /
    • 2003
  • This paper is concerned with level control of a upper plate in a vehicle. The objective of control is to maintain the upper plate at level regardless of road slopes. The road slope is detected using an accelerometer-type inclinometer and H infinity control method is used to simultaneously reduce effects of road slopes and sensor noises. By the simulation, it is shown that the upper plate is successfully maintained at level.

An Active Damping Device for a Distributed Power System (전력시스템을 위한 Active Damping Device)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Distributed power systems (DPSs) has been widely used various industrial/military applications due to their various advantages. Furthermore, the "All electric" concept, in conjunction with DC DPS, appears to be more advanced and mature in the AEV(All-Electric Vehicular) industry. Generally, AEV carry many loads with varied functions. However, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, a converter with spilt capacitors and a simple adaptive controller is proposed as a active damping device to mitigate the voltage transients on the bus. The proposed converter allows the smaller capacitive storage. In addition, the proposed control approach has the advantage of requiring only one sensor and performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. The control algorithm has been implemented on a TMS320F2812 Digital Signal Processor (DSP). Simulation and experimental results are presented which verify the proposed control principle and demonstrate the practicality of the circuit topology.

A Study on the Analysis and Improvement of Medical Device Standards in Korea (국내 의료기기 표준 분석 및 개선에 관한 연구)

  • Yong Wan Kang;Kyung Ah Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.204-210
    • /
    • 2023
  • This study focuses on analyzing medical device standards and regulatory requirements in the medical device industry, based on the Medical Device Act in Korea. The objective of this analysis is to determine whether the domestic standards for medical devices in Korea align with international and regional standards. Furthermore, it aims to identify the current application of domestic standards in ensuring the safety and essential performance of medical devices. The analysis revealed that out of a total of 281 domestic standards, 127 standards reference international standards. In terms of the application of domestic standards to specific items, there were 473 types of instruments/machines, 30 types of medical supplies, and 45 types of dental materials. However, the level of compliance with international standards among the domestic medical device standards was only 21%. Upon detailed analysis, general and collateral standards accounted for 24%, while particular standards accounted for 19%. This indicates a significant deviation from the latest international standards. On the other hand, the level of compliance with international standards was analyzed to be 60% for particular standards and 72% for general and collateral standards in Korean industrial standards (KS). Considering these results, the disparities between domestic standards and international standards underscore the need for discussions on domestic medical device regulation and standardization. In conclusion, this study emphasizes the significance of maintaining up-to-date medical device standards and ensuring their alignment with international standards to ensure the safety and quality of medical devices. The findings highlight the necessity for further efforts to strengthen the domestic standardization system in order to promote the development of safe and high-quality medical devices.

Modular Backpropagation Network to Diagnosing Plasma Processing Equipment

  • Kim, Byungwhan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.32.5-32
    • /
    • 2002
  • Processing plasmas are playing a crucial role in either depositing thin films or etching fine patterns. Any variability in process factors (such as radio frequency power or pressure) can cause a significant shift in plasma state. When this shift becomes large enough to change operating condition beyond an acceptable level, overall product quality can greatly be jeopardized. Thus, timely and accurate diagnosis of plasma malfunction is crucial to maintaining device yield and throughput. Many diagnostic systems have been developed, including HIPOCRATES [1] and PIES [2]. Plasma equipment was also diagnosed by combining neural network and expert system called Dempster-Schafer Theory [3]. A fact c...

  • PDF

Thermal Characteristic Analysis of IPMSM for Traction Considering a Driving Pattern of Urban Railway Vehicles (도시철도차량의 운행패턴을 고려한 견인용 IPMSM의 열 특성 분석)

  • Park, Chan-Bae;Kim, Jae-Hee;Lee, Su-Gil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.431-436
    • /
    • 2014
  • In this paper, temperature change properties on the 210kW-class Interior Permanent Magnet Synchronous Motor (IPMSM) are performed with the cooling performance of a water cooling device through the thermal characteristic analysis of the IPMSM considering a real driving pattern of urban railway vehicles. First, the thermal analysis modeling of 210kW-class IPMSM, which is an alternative to the conventional induction motor, and its water cooling device is conducted. Next, the thermal characteristic analysis of the IPMSM considering a real driving pattern of urban railway vehicles is performed using 2-Dimensional FEM tool. Finally, the calculated characteristic results are analyzed. Consequently, it is confirmed that the internal temperature of the 210kW-class IPMSM may be lowered to about 42~52% by maintaining the coolant flow rate of the water cooling device (Cross sectional shape of the pipe has 220mm width and 10mm height) for 0.2kg/s level.

The Impact of ISO 13485 on the Performance of Korean Medical Device Manufacturers (ISO 13485 인증 시스템이 경영성과에 미치는 영향 분석 : 국내 의료기기 제조업을 대상으로)

  • Kim, Chung-Yeon;Ko, Sung-Seok;Han, Yong-Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.11-23
    • /
    • 2018
  • This paper investigated relationship among internal as well as external motive to receive the ISO 13485 certification, countermeasure to the certification examination, active reception/execution level of the certification, and operational as well as financial performance of the medical device related enterprises in South Korea which received and are maintaining the ISO 13485 certification. SEM (structural equation model) and related analyses using AMOS 21.0 and SPSS 21.0 have been applied to verify the hypotheses of the research. Result of the research showed that internal as well as external motive for certification positively(+) affects active reception/execution level of the certification as well as countermeasure to the certification examination. The reception/execution level of the certification also positively(+) affects on the operational as well as financial performance of the certified enterprises. However, countermeasure to the certification examination was found out to negatively(-) affects the active reception/execution level of the certification and we can interpret that relatively more countermeasure to the certification examination burdens the employees of the enterprise, causing them to be less active on the reception/execution level of the certification. This research found that an enterprise's operational/financial performance improves when an enterprise introduces the ISO 13485 certification standard spontaneously on the purpose of improving its system and the certification system is applied to the enterprise actively, not passively. This research emphasizes the need to recognize the difference of the level of active reception implication among members of an enterprise according to the motive of introduction of the certification system.

Quality Control of Diagnostic X-ray Equipment in Medical Field (의료분야 진단용방사선발생장치의 품질관리)

  • Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2021
  • The examination using diagnostic x-ray equipment is one of the most useful diagnostic equipment for identifying information in the human body in diagnostic radiology. For this reason, the number of examinations has recently increased a lot. Increasing the number of examinations will accelerate the aging of the device. In addition, this makes them aware of the importance of quality control for the diagnostic x-ray device. Particularly, in a diagnostic x-ray device, quality control refers to an act of always maintaining a certain level of image quality by identifying and correcting all problems that may lead to reduction of the diagnosis area in advance. Therefore, this study summarizes and reports general information about quality control in examinations using diagnostic x-ray equipment.

Marketing strategy of urinary incontinence equipment in Europe (웰빙용 여성 요실금 치료기의 유럽 마케팅 전략)

  • Lee, Woo-Chun;Park, Roh-Gook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.1
    • /
    • pp.67-72
    • /
    • 2012
  • This study describes the environment change of an internal and external medical device market to be entered to European market of an urinary incontinence treatment device, is aimed at suggesting a participation plan analyzing urinary incontinence and treatments, and characteristic of new products & European urinary incontinence market. In conclusion, to sell the urinary incontinence treatment device developed as the world's first in European market, the following strategies are needed. First, the strategies domestic firms make family doctors and urologists heighten awareness of the urinary incontinence treatment device developed in Korea through participation of associations and exhibition being held in Europe to increase a market penetration level are needed. Second, it may be necessary to emphasize the fact that this devices are a characterful products and treatments, and cost-effectiveness treatments reducing infection ratio. Third, the domestic production firms of the urinary incontinence treatment device should suggest quality, delivery, and price consistency through looking for ways to lower the price while maintaining the quality in an increasingly competitive market conditions.

  • PDF

ADC-Based Backplane Receivers: Motivations, Issues and Future

  • Chung, Hayun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.300-311
    • /
    • 2016
  • The analog-to-digital-converter-based (ADC-based) backplane receivers that consist of a front-end ADC followed by a digital equalizer are gaining more popularity in recent years, as they support more sophisticated equalization required for high data rates, scale better with fabrication technology, and are more immune to PVT variations. Unfortunately, designing an ADC-based receiver that meets tight power and performance budgets of high-speed backplane link systems is non-trivial as both front-end ADC and digital equalizer can be power consuming and complex when running at high speed. This paper reviews the state of art designs for the front-end ADC and digital equalizers to suggest implementation choices that can achieve high speed while maintaining low power consumption and complexity. Design-space exploration using system-level models of the ADC-based receiver allows through analysis on the impact of design parameters, providing useful information in optimizing the power and performance of the receiver at the early stage of design. The system-level simulation results with newer device parameters reveal that, although the power consumption of the ADC-based receiver may not comparable to the receivers with analog equalizers yet, they will become more attractive as the fabrication technology continues to scale as power consumption of digital equalizer scales well with process.

Effect of Pintle Inflection Points on Performance of the SNECMA Modulatable Thrust Devices (핀틀의 변곡점 형상이 SNECMA 노즐목 가변 추력기의 성능에 미치는 영향)

  • Wang, Seung-Won;Huh, Hwan-Il
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.237-240
    • /
    • 2011
  • Numerical simulation was carried out to investigate the effect of pintle inflection point on the performance of the SNECMA modulatable thrust devices. Results show that the effect of inflection points in the pintle is to decrease aerodynamic load while maintaining required thrust level.

  • PDF