• 제목/요약/키워드: Level Shift

검색결과 901건 처리시간 0.024초

Onlay technique에 의한 매복중절치의 교정적 치험예 (A CASE OF PALATALLY IMPACTED INCISOR TREATED BY ONLAY TECHNIQUE WITH SURGICAL EXPOSURE)

  • 김광현;최목균;배창
    • 대한치과교정학회지
    • /
    • 제4권1호
    • /
    • pp.57-61
    • /
    • 1974
  • The patient, a girl of 19 years in good health, had a class I malocclusion. The maxillary left centra1 incisors and both lateral incisors had already erupted. But the space for the right central incisor was partially closed by the mesial drifting of the neighboring teeth. The caused a shift in the midline and a cross-bite relation on the incisors. X-ray examination revealed the presence of the right central incisor in the alveolar bone and odontoma just above the crown of the right central incisor. After enough space for the impacted incisor was created in the dental arch with a open-coil spring the rectangular incision was made. Removing the odontoma uncovered the flat surface of the labial aspect of the incisor. During the tooth had erupted of its own accord, any unnecessary force had been imposed on the tooth. When it was decided that the tooth should be brought out by the mechanical device, the gold cast onlay with hook was used and run a light elastic between this hook and the main arch wire. Finally the tooth was brought down to the arch level. The result was excellent. Fortunately the esthetic problem and any detrimental effects on the psychological make-up could be avoided.

  • PDF

A Piezoelectric Immunosensor for Early Cervical Cancer Detection

  • Yang, Li;Huang, Xianhe;Sun, Liang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권21호
    • /
    • pp.9375-9378
    • /
    • 2014
  • Background: A piezoelectric immunosensor for early cervical cancer detection was developed involving short analyis time and less invasive technique for $p16^{INK4a}$, a protein that has been linked to cervical cancer. Materials and Methods: $5{\mu}L$ of 5.0 mg/mL $p16^{INK4a}$ antibody and then supernatant from different clinical samples from West China Second University Hospital (Sichuan, China) were dripped on the center of the AT-cut crystal through a micro-injector. Absorption of the $p16^{INK4a}$ by antibody caused a shift in the resonant frequency of the immunosensor, and the resonant frequency was correlated to the amount of the $p16^{INK4a}$ in the supernatant. Results: The greater severity of lesion grading, the greater the expression level of $p16^{INK4a}$. Conclusion: Degree of cervical cancer lesion development could be determined by detected amount of $p16^{INK4a}$ in different clinical samples.

중소병원 간호사의 직무 스트레스와 임파워먼트가 간호업무성과에 미치는 영향 (Influence of Job Stress and Empowerment on Clinical Nurses' Performance in Small and Medium Hospitals)

  • 김영미;이여진
    • 한국직업건강간호학회지
    • /
    • 제21권3호
    • /
    • pp.258-265
    • /
    • 2012
  • Purpose: The purpose of this study is to identify the influence of job stress and empowerment on nursing performance of clinical nurses working in small and medium hospital. Methods: The empirical data were collected from a self-administered survey using a structured questionnaire with 404 nurses working in 4 medium-sized hospitals (less than 300 beds), located in I-city. The data were analyzed using stepwise multiple regression with the SPSS/WIN 17.0 program. Results: There were significant differences in nursing performance depending on general characteristics (age, marital status, religion, shift work, education level, position, clinical experience, department, and monthly salary). Empowerment correlated with nursing performance. Factors influencing on nursing performance were empowerment, clinical experience, job stress, and marital status with $R^2$ value of 36.3%. The most influencing factor was empowerment (${\beta}$=.47), followed by clinical experience (${\beta}$=.24), job stress (${\beta}$=.20), and marriage (${\beta}$=.12). Conclusion: It is needed to implement specific empowerment strategy, control job stress, and reward experienced and married nurses working in medium-sized hospital for improving nursing task performance.

HVCM(Hybrid Voice Coil Motor) Actuator적용을 통한 AUTO Focusing Camera Module 성능개선 (HVCM (Hybrid Voice Coil Motor) Actuator apply performance improvement through the AUTO Focusing Camera Module)

  • 권태권;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.307-309
    • /
    • 2011
  • 최근 출시되는 고사양의 Hand-phone 적용되어진 Camera Module은 대부분 Auto Focusing기능이 탑재되어 있으며 Camera Module의 화소수가 높아지면서 좀 더 정밀하고 안정적인 AF구동제품이 소비자에 의해 요구되고 있다. 본 논문은 현재 출시되고 있는 Camera Module적용 VCM(Actuator)의 문제점인 Auto Focusing시 Lens 초점위치 및 Module 자세에 따른 해상도편차 발생으로 해상도 보증 및 안정된 Actuator 구동을 위해 개선된 구조의 Hybrid VCM을 제안한다.

  • PDF

화소 설계 어레이 시뮬레이터 (PDAST)를 이용한 대면적 고화질을 위한 TFT-LCD의 화소설계 (YFY-LCD Pixel Design for Large Size, High Quality using PDAST(Pixel Design Array Simulator))

  • 이영삼;윤영준;정순신;최종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1364-1366
    • /
    • 1998
  • An active-matrix LCD using thin film transistors (TFT) has been widely recognized as having potential for high-quality color flat-panel displays. Pixel-Design Array Simulation Tool (PDAST) was used to profoundly understand the gate signal distortion and pixel charging capability, which are the most critical limiting factors for high-quality TFT-LCDs. Since PDAST can simulate the gate, data and pixel voltages of a certain pixel on TFT array at any time and at any location on an array, the effect of the resistivity of gate line material on the pixel operations can be effectively analyzed. The gate signal delay. pixel charging ratio, level-shift of the pixel voltage were simulated with varying the parameters. The information obtained from this study could be utilized to design the larger area and finer image quality panel.

  • PDF

섬망사정도구를 사용하는 중환자실 간호사의 섬망인식, 섬망사정의 장애요인 및 섬망사정 수행의 중요도 (The Perception of Delirium, Barriers, and Importance of Performing Delirium Assessment of ICU Nurses Utilizing the CAM-ICU)

  • 공경희;하이경;강인순
    • 중환자간호학회지
    • /
    • 제8권2호
    • /
    • pp.33-42
    • /
    • 2015
  • Purpose: This study was conducted to identify the perception, barriers, and importance of delirium assessment of intensive care unit nurses utilizing a tool for delirium assessment. Methods: The subjects were 150 intensive care unit nurses who routinely use the CAM-ICU to screen delirium. Data were collected using self-report questionnaires and analyzed using descriptive statistics and ranking. Results: Most intensive care unit nurses had experience of education about delirium and delirium assessment, and had assessed over once in a shift. However, a small number of nurses recognized utilizing their assessment result and the effect on higher mortality and underdiagnosed and preventable problem. The first rank of barriers was being too busy to assess patients and the second was difficulty of interpreting intubated patients. The importance of delirium assessment was considered lower than assessing catheter placement and level of pain. Conclusion: The study identified intensive care unit nurses' use of a delirium assessment tool, and the perception, barriers, and importance of delirium assessment. Furthermore, it is necessary to develop education programs to improve the early recognition of delirium by intensive care unit nurses.

우리나라 겨울철 기온과 북반구 대기 순환과의 상관성 분석 (Analysis on the Relationship between the Korean Temperature and the Atmospheric Circulation over the Northern Hemisphere during Winter)

  • 임소민;예상욱;김공래
    • 대기
    • /
    • 제22권2호
    • /
    • pp.187-197
    • /
    • 2012
  • This study investigates the relationship between the Korean temperature and the atmospheric circulation such as Arctic Oscillation, Siberian High and Aleutian Low during the winter (December-January) for the period of 1970-2011. It is found that all indices to represent aforementioned circulations are significantly correlated with Korean winter temperature for the period of 1970 - 2011. There are marked contrasts in such relationship, however, before and after the mid-1980s when a significant regime shift of Korean winter temperature occurred. While Korean winter temperature has a close relationship with Arctic Oscillation after the mid-1980s, its relationship with Siberian High and Aleutian Low is weakened. The composite analysis between a positive and negative phase of Arctic Oscillation before and after the mid-1980s is conducted to examine a recent strengthening of Arctic Oscillation-Korean winter temperature relationship. It is found that the structural changes of low-level wind and the geopotential height at 500 hPa between the two phases of Arctic Oscillation are more effective to influence Korean winter temperature after the mid-1980s. This may induce a close relationship between the Korean winter temperature variability and Arctic Oscillation after the mid-1980s compared to before the mid-1980s.

Sedative Effect of Sophora flavescens and Matrine

  • Lee, Hyun-ju;Lee, Sun-young;Jang, Daehyuk;Chung, Sun-Yong;Shim, Insop
    • Biomolecules & Therapeutics
    • /
    • 제25권4호
    • /
    • pp.390-395
    • /
    • 2017
  • The present study investigated the sedative effects of Sophora flavescens (SF) and its bioactive compound, matrine through performing locomotor activity test and the electroencephalography (EEG) analysis in the rat. The underlying neural mechanism of their beneficial effects was determined by assessing c-Fos immunoreactivity and serotonin (5-HT) in the brain utilizing immunohistochemical method and enzyme-linked immunosorbent assay. The results showed that SF and matrine administration had an effect on normalization of caffeine-induced hyperactivity and promoting a shift toward non-rapid eye movement (NREM) sleep. c-Fos-immunoreactivity and 5-HT level in the ventrolateral preoptic nucleus (VLPO), a sleep promoting region, were increased in the both SF and matrine-injected groups. In conclusion, SF and its bioactive compound, matrine alleviated caffeine-induced hyperactivity and promoted NREM sleep by activating VLPO neurons and modulating serotonergic transmission. It is suggested that SF might be a useful natural alternatives for hypnotic medicine.

Radical Surgical Excision and Use of Lateral Thoracic Flap for Intractable Axillary Hidradenitis Suppurativa

  • Teo, Wan-Lin;Ong, Yee-Siang;Tan, Bien-Keem
    • Archives of Plastic Surgery
    • /
    • 제39권6호
    • /
    • pp.663-666
    • /
    • 2012
  • Current treatments for hidradenitis suppurativa (HS) include prolonged courses of antibiotics, retinoids, immunosuppressants, and biologics. Severe cases that are resistant to prolonged medical treatment pose a therapeutic challenge. We propose radical excision and lateral thoracic flap reconstruction as a treatment option for such cases. In our experience with two patients, good aesthetic and functional outcomes were achieved, with a high level of patient satisfaction. The availability of suitable flap coverage allows for wide resection of all of the hair-bearing skin, leading to a low incidence of residual disease and subsequent recurrence. Following excision of the affected tissue, the ideal reconstructive method in the axilla provides suitable coverage without unacceptable donor site morbidity and also avoids axillary contractures. A long lateral thoracic flap with delay has excellent coverage with minimal donor tissue sacrifice. With a suitable flap coverage option, the management paradigm of intractable HS should shift from prolonged medical treatment to allow decisive radical excision, which will improve the quality of life for patients.

패키징으로 인한 응력이 MEMS 소자에 미치는 영향 분석 및 개선 (Effects of Package Induced Stress on MEMS Device and Its Improvements)

  • 좌성훈;조용철;이문철
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.165-172
    • /
    • 2005
  • In MEMS (Micro-Electro-Mechanical System), packaging induced stress or stress induced structure deformation becomes increasing concerns since it directly affects the performance of the device. In the decoupled vibratory MEMS gyroscope, the main factor that determines the yield rate is the frequency difference between the sensing and driving modes. The gyroscope, packaged using the anodic bonding at the wafer level and EMC (epoxy molding compound) molding, has a deformation of MEMS structure caused by thermal expansion mismatch. This effect results in large distribution in the frequency difference, and thereby a lower yield rate. To improve the yield rate we propose a packaged SiOG (Silicon On Glass) process technology. It uses a silicon wafer and two glass wafers to minimize the wafer warpage. Thus the warpage of the wafer is greatly reduced and the frequency difference is more uniformly distributed. In addition. in order to increase robustness of the structure against deformation caused by EMC molding, a 'crab-leg' type spring is replaced with a semi-folded spring. The results show that the frequency shift is greatly reduced after applying the semi-folded spring. Therefore we can achieve a more robust vibratory MEMS gyroscope with a higher yield rate.