• Title/Summary/Keyword: Level One Test Procedures

Search Result 72, Processing Time 0.027 seconds

Change Patterns on Subjective Distress Level in Gynecological Postoperative Patients with Different Levels of State Anxiety (불안수준에 따른 부인과 수술환자의 불편감지각의 변화 - 통증 자가 조절기 사용 중인 환자를 중심으로 -)

  • Suh, Young-Sook
    • Women's Health Nursing
    • /
    • v.11 no.4
    • /
    • pp.307-315
    • /
    • 2005
  • Purpose: A descriptive study was conducted to identify the change patterns on the level of perceived distress during the early postoperative period with regard to state anxiety in patients using patient controlled analgesia. Method: One hundred women who underwent elective hysterectomy procedures or other gynecologic surgeries completed a series of questionnaires measuring state anxiety, and subjective distress assessed by visual analog scales at 8, 24, & 48 hours postoperatively. Data were analyzed with frequencies, percentages, means, ANOVA, Repeated Measures ANCOVA, and Scheff'e post test utilizing SPSS WIN 11.0. Result: There was a gradual decrease in levels of total distress and pain over the three points in time after surgery regardless the levels of state anxiety. However, women with higher levels of anxiety their pain curve rose at 48 hours post-op. In addition, over the first two points in time, women in the higher anxiety group showed higher levels of distress than those in the lower anxiety group, but no such group differences were observed in the levels of pain, revealing higher pain levels only at 8 hours post-op in both groups. Conclusion: Irrespective of effective pain management modality, most postoperatively experienced distress in gynecological patients was derived from anxiety and pain. These findings have implications for pain management, especially in patients with emotionally charged surgeries like hysterectomy.

  • PDF

Study on icebreaking performance of the Korea icebreaker ARAON in the arctic sea

  • Kim, Hyun-Soo;Lee, Chun-Ju;Choi, Kyung-Sik;Kim, Moon-Chan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.3
    • /
    • pp.208-215
    • /
    • 2011
  • A full-scale field trial in ice-covered sea is one of the most important tasks in the design of icebreaking ships. The first Korean icebreaking research vessel 'ARAON', after her delivery in late 2009, had a sea ice field trial in the Arctic Sea during July-August, 2010. This paper describes the test procedures and data analysis on the icebreaking performance of the IBRV ARAON. The data gathered from the icebreaking performance test in the Chukchi Sea and the Beaufort Sea during the Arctic voyage of ARAON includes the speed and engine power of the ship as well as sea ice thickness and strength data. The air temperature, wind speed and heading of the ship were also measured during each sea ice trial. The ARAON was designed to break 1 m thick level ice with a flexural strength of 630kPa at a continuous speed of 3knots. She is registered as a KR POLAR 10 class ship. The principal dimensions of ARAON are 110 m, 19 m and 6.8 m in length, breadth and draft respectively. She is equipped with four 3,500kW diesel-electric main engines and two Azipod type propulsion motors. Four sea ice trials were carried out to understand the relationship between the engine power and the ship speed, given the Arctic ice condition. The analysis shows that the ARAON was able to operate at 1.5knots in a 2.5m thick medium ice floe condition with the engine power of 5MW, and the speed reached 3.1 knots at the same ice floe condition when the power increased to 6.6MW. She showed a good performance of speed in medium ice floe compared to the speed performance in level ice. More detailed analysis is summarized in this paper.

TIME-DEPENDENT DEFORMATION OF POLYMER-BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS

  • Pae Ahran;Jeong Mi-Sook;Kim Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.717-726
    • /
    • 2005
  • Statement of problem. One of the common problems of provisional crown and fixed partial denture materials is that when they are subjected to constant loads for a long period of time, they exhibit a dimensional change (creep). Purpose. The aim of this study was to investigate the viscoelastic behaviour of polymer-based provisional crown and fixed partial denture materials with time at constant compressive load. Material and methods. Three dimethacrylate-based materials (Protemp 3 Garant, Temphase, Luxatemp) and one monomethacrylate-based material (Trim) were selected. Dimensional changes of the specimens were recorded by a LVDT to evaluate their viscoelastic behavior and creep strain. For all specimens, two loading procedures were used. At first, static compressive stress of 4 MPa was applied for 30 minutes and followed by 1 hour of strain recovery. Then, after 24 hours of water storage, the specimens were loaded again. The creep values between materials were statistically analyzed using one-way ANOVA and multiple comparison $Scheff\acute{e}$ test. Independent samples t-test was also used to identify the difference of creep strain between first and secondary loading conditions at the significance level of 0.05. Results. Following application of the first loading, Trim showed the highest maximum creep strain (32.7%) followed by Luxatemp, Protemp 3 Garant and Temphase, with values of 3.78%, 2.86% and 1.77%, respectively. Trim was significantly different from other materials (P<0.05), while there were no significant differences among Luxatemp, Protemp 3 Garant and Temphase (P>0.05). The highest recovery and permanent set of Trim, were significantly different from those of others (P<0.05). At the secondary loading of the dimethacrylate-based materials, creep deformation, recovery and permanent set decreased and the percentage of recovery increased, while in Trim, all values of the measurements increased. This result showed that the secondary loading at 24 hours produced a significant creep magnitude. Conclusion. The dimethacrylate-based provisional crown and fixed partial denture materials showed significantly higher creep resistance and lower deformation than the monomethacrylate-based material. Thus, monomethacrylate-based materials should not be used in long-term stress-bearing situations.

Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts

  • Choi, Jae Hyung;Cho, Young Soon;Lee, Jung Won;Shin, Hee Bong;Lee, In Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.3
    • /
    • pp.158-164
    • /
    • 2017
  • Objectives: To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods: One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were considered negative (not contaminated) if no colonies were present on the blood agar plate after an 18-hour incubation period. Samples were stratified by hospital and according to the frequency of intubation attempts (10 attempts per year) using the ${\chi}^2-test$ and Fisher exact test. Results: One or more species of bacteria were isolated from 4 (5.6%) handle tops, 20 (28.2%) handles with knurled surfaces, and 27 (18.2%) blades. No significant differences were found in microbial contamination levels on the handle tops and blades between the two hospitals and two areas according to the frequency of intubation attempts. However, significant differences were found between the two hospitals and two areas in the level of microbial contamination on the handles with knurled surfaces (p<0.05). Conclusions: Protocols and policies must be reviewed to standardize procedures to clean and disinfect laryngoscope blades and handles; handles should be re-designed to eliminate points of contact with the blade; and single-use, one-piece laryngoscopes should be introduced.

An artificial noise generation method for MODEM performance test in satellite communication system (위성통신 시스템에서 수신기 모뎀 성능을 시험하기 위한 인위 잡음 발생 방법)

  • Cho, Tae-Chong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.59-64
    • /
    • 2020
  • Occasionally, MODEM test in satellite communication systems are needed. But Rx terminals in satellite communications are designed to obtain high SNR generally, therefore artificial bad conditions and environments are demanded for the test. One of the typical method is satellite output power reduction. Using noise generator can be another method. However, these costs a lot of money, time, and procedures in reality. In order to overcome these problems, this paper proposes an artificial noise generation method for MODEM test in satellite communication systems. First of all, SNR of a general heterodyne Rx terminal is calculated. Based on the calculation, a new model which is including variable attenuator is proposed to increase noise level. Simulation results illustrate the variable attenuator can control SNR, and these show that MODEM test in satellite communication systems be possible.

Diagnostic Evaluation of Serum FSH and LH in Primary Amenorrhea by Radioimmunoassay (방사성 면역측정상의 혈청 FSH와 LH에 관한 일차성 무월경증 환자의 진단적 고찰)

  • Hong, I.S.;Kim, G.E.;Yoo, H.S.;Lee, J.T.;Park, C.Y.;Ryu, K.J.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.37-44
    • /
    • 1980
  • The usefulness of single, random measurements of serum FSH and LH in the diagnosis of primary amenorrhea by radioimmunoassay was investigated. The 16 patients were divided into 3 groups by the level of serum FSH and LH. The first group with increased level of serum FSH and LH is five patients, all of these are related to the acquired or congenital abnormality of the ovary. Further studies indicated include buccal smear, chromosome analysis, gynecography and laparosocopy. The second group with normal serum FSH and LH is nine patients, four patients of these are related to the developmental anomaly of the Mullerian duct and five patients are undo etermined origin. Further studies indicated include laparoscopy and gynecography. The third group with decreased serum FSH and normal or decreased serum LH is two patients, one of these is related to the pituitary function, isolated FSH deficiency, the other is undetermined origin. Further studies indicated include the pituitary function test, LH-RH stimulation test, skull radiography. Determination of serum FSH and LH levels does not permit a specific etiologic diagnosis of primary amenorrhea. However the serum levels of FSH and LH can be used to differentiate the principal area of the investigation and can be of assistance in choosing more specific testing procedures.

  • PDF

Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries

  • Prasetyono, Theddeus O.H.;Koswara, Astrid Felicia
    • Archives of Plastic Surgery
    • /
    • v.42 no.2
    • /
    • pp.164-172
    • /
    • 2015
  • Background The use of a tourniquet in hand surgery is generally accepted as necessary to create a clear visualization of the operative field. This study aims to determine the effectiveness of one-per-million tumescent solution (1:1,000,000 epinephrine concentration) in creating a bloodless operative field in post-burn hand deformity surgeries performed without a tourniquet. Methods This retrospective observational study was conducted on a series of 12 patients with post-burn hand deformities who underwent surgery between February 2013 and January 2014. A total of 29 operative fields were recorded. The one-per-million tumescent solution was used for hemostatis instead of a tourniquet. The clarity of the operative field, volume of solution injected, duration of surgery, scar thickness and density, and functional outcomes at least three months after the surgery were observed. The relationship of scar thickness and density with the clarity of the operative field was analyzed with the chi-square test. Results Of the 29 operative fields in which the one-per-million tumescent technique was used, 48.2% were totally bloodless, 44.8% had minimal bleeding, and 6.9% had an acceptable level of bleeding. Both scar thickness and density were shown to have a significant relationship with operative field clarity (P<0.05). Conclusions The one-per-million tumescent technique is effective in facilitating post-burn hand deformity surgeries involving meticulous, multiple, and lengthy procedures by creating a relatively clear operative field without the use of a tourniquet. Although scar thickness and density are associated with the clarity of the operative field, this technique can be considered safe and effective in creating a clear operative field.

A Study on the Standard Setting for the Basic Skills Competency Test: Focusing on 3rd Grade Basic Mathematics (기초학력 진단평가의 성취수준 설정에 관한 연구: 초등학교 3학년 '기초수학' 사례를 중심으로)

  • Kim, HeeKyoung;Cho, Seongmin
    • Journal of the Korean School Mathematics Society
    • /
    • v.16 no.3
    • /
    • pp.479-498
    • /
    • 2013
  • As education is one of key factors to improve national competitiveness, quality education becomes a top priority in all countries around the world. In South Korea, The Basic Skills Competency Test is administered annually to select below-basic third graders and provide intervention programs. The Basic Skills Competency Test was designed to diagnose the minimal competency of third graders according to a national-level standards. The purpose of this study was to analyze standard-setting procedures and set cut-off scores. This study offered the empirical evidence that standard-setting is generally applicable in schools by the modified Ebel method. More future researches addressing appropriate and efficient standard-setting methods in real school situations are needed to be taken in.

  • PDF

Nurse's Job Satisfaction and Organizational Commitment according to Hospital Ethical Climate Types (병원조직의 윤리풍토가 간호사의 직무만족, 조직몰입에 미치는 영향)

  • Noh, Yoon Goo;Jung, Myun Sook;Lee, Young Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.19 no.4
    • /
    • pp.513-524
    • /
    • 2013
  • Purpose: This study was conducted to identify ethical climate factors in hospitals and analyze their influence on job satisfaction and organizational commitment. Methods: A convenience sample of 196 nurses from one national university hospital in J city participated in this descriptive study survey. Instruments included the Ethical Climate Questionnaire, Job Satisfaction Scale, and Organizational Commitment Scale. Cronbach's ${\alpha}$ and factor analysis were done to test reliability and construct validity of the scales. Data were collected from March 15 to March 25, 2013 and analyzed using descriptive statistics, one-way ANOVA, t-test, Pearson correlation, and multiple regression with SPSS/WIN 18.0. Results: Seven ethical climate factors were identified; laws and professional codes, social responsibility, company rules and procedures, self-interest, personal morality, efficiency, and friendship. Factors influencing job satisfaction were friendship (${\beta}$=.25), social responsibility (${\beta}$=.20), laws and professional codes (${\beta}$=.20), and educational level (${\beta}$=.27), explaining 37.6% of variance in job satisfaction. Factors influencing organizational commitment included social responsibility (${\beta}$=.29), friendship (${\beta}$=.27), laws and professional codes (${\beta}$=.23), and age (${\beta}$=.19), with explanatory power of 44.6%. Conclusion: Results can be used as preliminary data for developing new strategies to establish positive ethical climates in hospital environments and thus enhance nurses' job satisfaction and organizational commitment.

A Study on Standardization of Test Method for Water Vapour Permeability of Textiles Fabrics (군용 피복류의 투습도 시험방법 표준화 연구)

  • Lee, Min-Hee;Hong, Seong-Don;Chung, Il-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.27-33
    • /
    • 2016
  • Military textiles with breathable waterproof materials are expanding as form of winter clothes. Waterproof moisture-permeable clothes are very important for soldiers to survive in cold weather operations because they prevent loss of body heat from the penetration of water into the human body. Korea military uses the water resistance and moisture permeability to test the performance of waterproof moisture-permeable materials. Moisture permeability is measured according to the amount of evaporated water vapor passing through a fabric under specified temperature and humidity by using acetic acid potassium presented in KS K 0594. However, the test procedure for measuring the moisture permeability in the standard is presented only briefly and the preparation procedures for the test in accredited testing institutions are applied differently, leading to significant deviation of the results. This paper compares the procedures of testing institutions and examines the factors that affect moisture permeability. Finally, we propose a procedure to reduce the deviation of results and apply the proposed procedure in testing institutions. Our analysis results with one-way ANOVA under significant level (0.05) confirm that the deviation of results is reduced.