• Title/Summary/Keyword: Lens transmittance

Search Result 114, Processing Time 0.023 seconds

A Study on Electromagnetic Shield Coating of Ocular Lens (안경렌즈의 전자파 차폐 코팅에 관한 연구)

  • Kim, Ki-Hong;Park, Dae-Jin;Kim, In-Su
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2006
  • Electromagnetic shielding, transparent ITO coating layers have deposited on ocular lens substrate by magnetron sputtering. We investigated the effect induced by the substrate temperature on coating layer. The characteristics of the coating layers were analyzed using surface profiler, four-point probe, XRD, spectrophotometer and Auger Electron spectroscopy. As substrate temperature became higher, carrier concentration was increased and transmittance in the visible region was increased, too.

  • PDF

Layout of Long-pass-edge Filter Correspond with the Optical Transmission in Crystalline (수정체 광투과에 대응하는 LPE Filter 설계)

  • Kim, YongGeun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.57-63
    • /
    • 1999
  • The optical absorption and transmittance of cow' crystalline were measured by spectrophotometer in the 200~800nm wavelength regions. The optical absorptions of crystalline composed of a high absorption band in the UV-A, UV-B, and appeared the light transmittance edge in the 400nm wavelength region, and completely transmitted without the absorption in the high wavelength regions than 400nm. Also, the optical absorption and transmittance had no temperature dependence. The optical transmittance spectrum of crystalline concord with the thin film structure of $n_0/(0.5H)L(LH)^6(0.5H)/n_s$ and $n_0{\mid}(0.5LH0.5L)^kL/1.25{\mid}4.0$ of long-pass edge filter form. In the artificial crystalline and inter lens layout, long-pass edge filter layout can UV cut off.

  • PDF

Study of the coloration factors of tinted lenses (착색렌즈의 색비율 정량화에 관한 연구)

  • Lim, Yong-Mu;Shim, Moon-Sik;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.37-46
    • /
    • 2001
  • In this study, We compared the properties of tinted and colored lenses with the standards m the ordinary optical properties, coloration, UV, IR and luminous transmittance, color acceptance for traffic signal, and chromaticity. The UV, lR and luminous transmittance was analysed in the range of 175 nm to 3000 nm by using a UV-Vis-IR spectrophotometer and was used in the synthesis of spectrum of various color lens. A experimental function was made from the slope obtained from the transmittance change as a function of coloration time. We could expect the ordinary optical properties and color acceptance for traffic signal of various color lenses with the requirements of US standard(ANSI Z-80.3).

  • PDF

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Assessment of UV Blocking Performance for Development of Converged Technologies of Vision Correcting Spectacle Lenses (시력교정용 안경렌즈의 융복합적 기술개발을 위한 UV차단 성능 평가)

  • Kim, Heung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.93-98
    • /
    • 2018
  • This study was wanted to confirm ability for UV blocking according to its material. The lenses materials were Acryl, CR-39, NK-55, and MR-8. It was grouped: Group A consisting of anti-scratch hard coated lenses and anti-refractive multi coated lenses, Group B added UV blocking coating on the group A, and Group C consisting of only UV blocking lenses. The results measured UV transmittance, On the UV-A wavelength, Group A showed the UV transmittance of 7.726%, 0.043%, 0.007%, and 0.007% respectively. Group B showed 0.038%, 0.037%, 0.007%, and 0.007%, respectively. The UV-blocking performance of CR-39 has been greatly improved. Group C has shown the best UV blocking function; only 0.005% and 0.004% of UV transmittances.(1.60 and 1.67 index of refraction respectively). For the low power of lenses and sunglasses, the CR-39 lens is the most used. Therefore, to UV blocking from the lens, new materials or UV absorbers or UV coating technology and development of Converged Technologies are required.

Physical Properties Assessment of Soft Contact Lens with Halogen and Carboxylic Substituted Pyridine as Additive (할로겐과 카르복시산으로 치환된 피리딘 첨가제를 사용한 소프트 콘택트렌즈의 물성 평가)

  • Kim, Duck-Hyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.437-443
    • /
    • 2015
  • Purpose: This study evaluated the optical and physical and characteristics of soft contact lens polymerized with addition of 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine-4-carboxylic acid in the basic hydrogel contact lens material. In particular, the utility of 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine- 4-carboxylic acid as a hydrogel contact lens material was investigated. Methods: In this study, 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine-4-carboxylic acid were used as additives. Also, 2-hydroxyethyl methacrylate, acrylic acid, methyl methacrylate and a cross-linker EGDMA were co-polymerized in the presence of AIBN as an initiator. Results: The physical properties of the produced polymers were measured as followings. The water content of 34.54~37.15%, refractive index of 1.4320~1.4342, tensile strength of 0.2872~0.3608 kgf and contact angle of $57.82{\sim}79.57^{\circ}$, UV-B transmittance of 76.8~82.4% and UV-A transmittance of 84.6~86.6% were obtained respectively. Conclusions: Based on the results of this study, contact lens material containing 3-chloropyridine-4-carboxylic acid and 3-fluoropyridine-4-carboxylic acid is expected to be able to used as a material for high wettability and UV-block hydrogel contact lens.

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

Preparation and Characteristics of Photochromic Plastic Lenses by Hard Coatings (하드코팅에 의한 광변색 플라스틱 렌즈의 제조 및 특성)

  • Yu, Dong-Sik;Ha, Jin-Wook;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1635-1641
    • /
    • 2009
  • In this study, we have prepared plastic lenses with both photochromic and hard properties by hard coating, and evaluated their optical properties and surface characteristics. Photochromic effects could be observed on the UV spectra of the closed forms and the visible spectra of the open forms. Visible light transmittance of photochromic lenses was from 83.44% for graphite(GP) to 85.15% for blue(BL) in colourless state and from 71.10% for red(RE) to 79.98% for yellow(YE) in colour state. Red photochromic lens was higher in optical density(${\Delta}$OD) and color difference(${\Delta}$$E^{\ast}_\;{ab}$) than the others. Photochromic lenses applied by hard coating showed good adhesion, hot water resistance, chemical resistance and surface appearance. Also, compared to the uncoated lens, hardness and abrasion resistance were increased. Consequently, this coating system could impart functional properties such as photochromic and hard coating property onto ophthalmic lenses.

Polymerization and Physical Property Assessment of Optical Lens Materials Containing Amide Group

  • Lee, Min-Jae;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.2
    • /
    • pp.113-117
    • /
    • 2018
  • The basic hydrogel lens with addition of N,N-dimethylacrylamide (DMA) and N-methyl-N-vinylacetamide (NMV) were manufactured. The optical and physical characteristics of ophthalmic lens were evaluated by measuring water content, oxygen permeability (Dk), refractive index and optical transmittance. The water content & oxygen permeability (Dk) of sample containing Ref., DMA group and NMV group was in the average of 34.48%, 35.54~49.19% & $13.003{\sim}18.468{\times}10^{-11}(cm^2/sec)$($mlO_2/ml{\times}mmHg$) and 36.28~44.95% & $12.270{\sim}16.883{\times}10^{-11}(cm^2/sec)$ ($mlO_2/ml{\times}mmHg$), respectively. And also, refractive index of the sample containing Ref., DMA group and NMV group was in the average of 1.4350, 1.4330~1.4131 and 1.4335~1.4195, respectively. Standard hydrogel monomer containing DMA and NMV was expected to be used usefully as a material for fabricating hydrophilic functional ophthalmic lens.

Elution Properties of Naringin from Soft Contact Lens Containing Naringin (나린진(naringin)이 함유된 소프트 콘택트렌즈에서 나린진의 용출 특성)

  • Ryu, Geun-Chang;Jun, Jin;Jin, Moon-Seok;Chae, Soo-Chul;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: A soft contact lens was manufactured by adding naringin known as natural anti-bacterial material to resin solution. With solution eluted from manufactured contact lens, we examined its optical properties, physical and chemical states of naringin in the polymer, and elution properties. Methods: The soft contact lens with naringin was synthesized by bulk polymerization method. IR spectrum and HPLC were used to define the bonding type of naringin itself in the soft contact lens contained naringin, elution process of naringin to the saline solution, and the amount of naringin solution eluted from the lens with elapsed time. Results: Naringin was continuously eluted with constant concentration from the soft contact lens for about a month and the structure ofnaringin which is eluted was as same as before it was added to resin solution. Any change in optical properties such as transmittance couldn't be found. Bonding state and the structure of naringin in contact lens were explained with IR spectrum and HPLC results. Conclusions: In the contact lens with naringin, naringin remained in the contact lens bonding with weak hydrogen bonding and/or van der Waals force between naringin and polymer. Naringin was continuously eluted from the contact lens contained naringin during about 1 month. Even after 1 month, it showed that the concentration of the naringin eluted was approximately 10 ppm in a day. From the results, adding naringin to the soft contact lens resin is very effective method for manufacturing the soft contact lens which has anti-bacterial function for a period of time.

  • PDF