• Title/Summary/Keyword: Lens surface

Search Result 611, Processing Time 0.029 seconds

Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan (안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가)

  • Moon, Se-Young;Hong, Sang-Woo;Seo, Ji-Sook;Kim, Yeong-Beom;Kwak, Wan-Sin;Lee, Seong-Yeong;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

Design of Cooled Infrared Optical System Considering Narcissus (나르시서스를 고려한 냉각형 적외선 광학계 설계)

  • Jeong, Su Seong;Kim, Young Soo;Hong, Jin Suk;Lee, Kyoung Muk;Yoon, Jee Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.219-225
    • /
    • 2019
  • In an infrared optical system, using a cooled detector generates a phenomenon called a narcissus, in which the focal-plane array cooled to very low temperatures is reflected at the lens surface and detected. The narcissus can be removed by non-uniformity correction of the detector pixel, so narcissus is generally ignored in infrared optics. However, non-uniformity correction reduces the sensitivity of the system. Also, as the housing temperature varies due to an environmental temperature change, or a lens is moved for focusing or athermalization purposes, a narcissus may occur even after non-uniformity correction. To minimize such a narcissus, the amount of the effect must be controlled in the lens-design stage. In this paper we designed a midinfrared optical system and analyzed the narcissus by setting the lens surface reflectance to 1%. In addition, the design was divided into stages of an initial design, an improved design, and a minimum design, and the narcissus was improved to about 56% of that in the initial design.

Optical Models of the Finite Schematic Eyes for Presbyopia (노안을 위한 정밀 모형안 설계)

  • Baarg, Saang-Bai
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.439-447
    • /
    • 2008
  • There is a need for a finite schematic presbyopic eye that models vision and image quality under various conditions such as cataract or refractive surgery, as well as near vision corrections with an ophthalmic lens or contact lens. Using recently measured biometric data of presbyopic eyes, new model eyes were designed that are optically and anatomically close to real eyes. The parameters changing significantly with age were incorporated into models for four different age groups. The new model eyes have alpha angle, decentered pupil, aspheric GRIN lens and aspheric retinal surface. It is likely that the new finite presbyopic model eyes will be useful for designing visual instruments such as low vision aids, PALs, IOL and contact lenses, and for the clinical prediction of the retinal image quality of a presbyopic patient.

The morphological study of Cornea in Man College Students (남자대학생들의 각막 형태 연구)

  • Kim, Douk Hoon;Yoo, Jae Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.89-93
    • /
    • 2002
  • The physiology and morphology of cornea has effected on the ocular refractive status. Therefore the measurement of the anterior corneal surface by keratometer is used the treatment of the spectacles and contact lens by optician, optometrist, and ophthalmologist. Furthermore, currently the most corneal topographic mapping system have used the clinical optical shop, eye research center, and eye hospital. Because this method have a very fine data comparative to the previous instrument. The authors have measurement the cornea of the man college students by the corneal topographic mapping method. Especially this data will applied the clinical practice for the contact lens fitting. Especially in Korea, many man college students use the contact lens for the visual acuity and a beauty. Therefore the contact lens wear have increase per every year.

  • PDF

Study on the Superprecision Glass Molding of Aspherical Lens for Optical Communication Module (광통신용 비구면 렌즈 초정밀 성형 공정 연구)

  • Jang, Kyung-Su;Lee, Tae-Ho;Rho, Tae-Yung;Kim, Chang-Seok;Jeong, Myung-Yung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.18-24
    • /
    • 2010
  • Efforts to obtain more efficient coupling of light from a laser diode to a single mode fiber have continued for various applications such as links for optical fiber communication systems. In TO-can package, configuration of optimized aspherical lens is bi-aspheric and its diameter is 2.4mm. We designed and fabricated aspherical coupling lens by means of glass molding technique under consideration of glass shrinkage. By controlling the aspherical profile error and surface roughness which were below 90nm and 10nm, respectively, we obtained the low coupling loss, 5.40dB, which was able to use for coupling a single mode fiber to laser diode.

A Novel Broadband Horn Antenna with Quadruple-Ridged Waveguide and Dielectric Lens (4중 릿지 도파관과 렌즈를 이용한 새로운 광대역 혼 안테나)

  • Lee, Kee-Oh;Park, Dong-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.135-141
    • /
    • 2008
  • In this paper, a design method of broadband horn antenna having 3:1 bandwidth and multiple polarization characteristics is proposed. The feeding section of the antenna adopts quadruple-ridged waveguide type for broadband and multiple polarization characteristics of the antenna. By inserting a shorting bar in the cavity structure with a semi-sphere type back short, the return loss at the feeding section was minimized. A corrugated dielectric lens is designed for phase compensation and lens-surface matching at the antenna aperture, which improves the antenna beam pattern. The validity of the design method is verified by indicating the measured data of the antenna.

Investigation of Asymmetric Aspherical Triangular Prism Optical System for Video Information Display (영상정보디스플레이용 비대칭 비구면 삼각 프리즘 광학계 연구)

  • Youn, Gap-Suck;Yoo, Kyung-Sun;Hyun, Dong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.590-595
    • /
    • 2014
  • We have investigated anamorphic prism lenses with distortions of 0.3-0.5%. We designed the plastic triangular lens and confirmed the minimum resolution using MTF graphs. Also we confirmed that the SVGA optical system can realize a resolution of $864{\times}648$ 56 megapixels. A distortion of about 0.5% aberration appears in the maximum field, and a finite beam aberration of about $15{\mu}m$ is confirmed. We made a mold based on the design data and completed the prism lens through exodus molding. We confirmed the shape error (< $30{\mu}m$) and surface roughness (> 40 nm) of the three sides. We made the video-information-display prototype glasses using prism lens by measuring the performance, we determined the distortion aberration (0.3%) and SVGA resolution. Our approach will enable fabrication of a portable large-screen display device for glasses and sunglasses for the domestic market and, after 2015, for the world market.

A study on the fabrication method of middle size LGP using continuous micro-lenses made by LIGA reflow

  • Kim, Jong-Sun;Ko, Young-Bae;Hwang, Chul-Jin;Kim, Jong-Deok;Yoon, Kyung-Hwan
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.3
    • /
    • pp.171-176
    • /
    • 2007
  • LCD-BLU (Liquid Crystal Display-Back Light Unit) of medium size is usually manufactured by forming numerous dots with $50{\sim}300\;{\mu}m$ in diameter by etching process and V-grove shape with $50\;{\mu}m$ in height by mechanical cutting process. However, the surface of the etched dots is very rough due to the characteristics of the etching process and V-cutting needs rather high cost. Instead of existing optical pattern made by etching and mechanical cutting, 3-dimensional continuous micro-lens of $200\;{\mu}m$ in diameter was applied in the present study. The continuous micro-lens pattern fabricated by modified LIGA with thermal reflow process was tested to this new optical design of LGP. The manufacturing process using LIGA-reflow is made up of three stages as follows: (i) the stage of lithography, (ii) the stage of thermal reflow process and (iii) the stage of electroplating. The continuous micro-lens patterned LGP was fabricated with injection molding and its test results showed the possibility of commercial use in the future.

Fabrication of Lenticular Lens by Continuous UV Roll Imprinting (UV Roll 임프린팅 공정을 이용한 렌티큘러 렌즈 제작)

  • Myung H.;Cha J.;Kim S.;Kang S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.91-94
    • /
    • 2005
  • With increasing demands for large-scale micro-optical components in the field of digital display, the establishment of large-scale fabrication technology fur polymeric patterns has become a priority. The starting point of any polymer replication process is the mold, and the mold often has flat surface. However, It is very hard to replicate large-scale micro patterns using the flat mold, because the cost of large-scale flat mold was very high, and some uniformity and releasing problems were often occurred in large scale flat molding process. In this study, a UV roll imprinting system to overcome the financial and fabrication issues of large-scale pattern replication process was designed and constructed. As a practical example of the system, a lenticular lens with radius of curvature of $223{\mu}m$ and pitch of $280{\mu}m$, which was used to provide wide viewing angle in projection TV, was designed and fabricated. The roll stamper was fabricated using direct machining process of aluminum roll base. Finally, the shape accuracy and uniformity of roll imprinted lenticular lens sheet were measured and analyzed.

  • PDF

Effect of TiC amount on Fracture Toughness of materials for glasses lens cutting (TiC함량이 안경렌즈 절삭용 재료 파괴인성에 미치는 영향)

  • Lee, Young Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.207-210
    • /
    • 2000
  • The SiC-TiC composites materials for glasses lens cutting were fabricated by hot-pressing and annealing. The amount of TiC was 0, 10, 20, 30wt% in the mixture of ${\beta}-SiC$. The microstructure of materials for glasses lens cutting was very dependent on the TiC amount. The introduction of larger amount of TiC improved fracture toughness, optical microscope and XRD analysis of the surface of samples were carried out. An in situ-toughened microstructure, consisted of distributed elongated SiC, matrix like TiC grains was developed by using ${\beta}-SiC$. Typical hardness and fracture toughness of materials for spectacle lens cutting were 14.9 GPa and $5.7MPa{\cdot}m^{1/2}$, respectively.

  • PDF