• Title/Summary/Keyword: Lens model

Search Result 337, Processing Time 0.029 seconds

Cure and Heat Transfer Analysis in LED Silicone Lens using a Dynamic Cure Kinetics Method (승온 반응속도식을 이용한 LED용 실리콘 렌즈의 경화 및 열전달해석)

  • Song, M.J.;Kim, K.H.;Hong, S.K.;Park, J.Y.;Lee, J.W.;Yoon, G. S.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.101-106
    • /
    • 2015
  • Recently, silicone is being used for LED chip lens due to its good thermal stability and optical transmittance. In order to predict residual stresses, which cause optical birefringence and mechanical warpage of silicone, a finite element analysis was conducted for the curing of silicone during molding. For the analysis of the curing process, a dynamic cure kinetics model was derived based on the results of a differential scanning calorimetry (DSC) testing and applied to the material properties for finite element analysis. Finite element simulation results showed that a step cure cycle reduced abrupt reaction heat and showed a decrease in the residual stresses.

Low-Complexity Lens-shading Correction Algorithm based on Piece-wise Linear Model (낮은 복잡도를 가지는 구간선형 모델 기반 렌즈음영왜곡 보상 알고리즘)

  • Lee, Bora;Park, Hyun Sang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.49-52
    • /
    • 2011
  • 본 논문에서는 구간선형 모델을 적용하여 낮은 복잡도를 가지는 LSC(Lens-Shading Correction) 알고리즘을 제안한다. 제안한 알고리즘은 각 화소와 렌즈 중심점으로부터 거리를 정수형으로 계산하고, 이 정수를 거리에 대한 LSC 이득값이 저장된 LUT(Look-Up Table)에 대한 주소로 적용하여, 입력 화소 값에 곱함으로써 LSC를 수행한다. 거리를 구하려면 제곱근 회로가 추가되어야 한다. LUT에 저장된 이득값은 원점으로부터의 거리에 대한 평균 이득값을 저장하고 있기 때문에, 제곱근 계산에 높은 정밀도를 할애하여도 LSC 보상된 영상의 화질에 미치는 영향은 높지 않으므로 정수형 제곱근 연산을 수행한다. 제곱근 계산은 구간 선형화하여 단지 덧셈과 쉬프트 연산만으로 제곱근 연산을 완료할 수 있도록 간략화 하였다. 제안한 알고리즘을 양산 중인 일반 카메라 모듈에 적용한 결과, 카메라모듈 제조업체의 LSC 평가 기준을 상회하는 수준으로 나타나며, 구현될 하드웨어 복잡도가 매우 낮아서 모바일 카메라 구현에 매우 적합하다.

  • PDF

Convergence Point Adjustment Improving Visual Discomfort for a Zoom on a Stereoscopic Camera

  • Ha, Jong Soo;Kim, Dae Woong;Kim, Dong Hyun
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.633-640
    • /
    • 2016
  • In a dual lens stereoscopic camera, a convergence point determines the stereopsis effects of a video. When a user zooms an object, a convergence point is fixed since it is not coupled with a zoom function. Due to the fixed convergence point, it is possible for a zoom to cause the excessive binocular disparity resulting in visual discomfort. In this paper, to solve this problem, we build the relational model including all phenomena possible to arise and propose the adjustment methods of a convergence point by the positions of a focus, an object and a convergence point. We also evaluate the experiments measuring a binocular disparity and the subjective test to investigate the visual comfort. The results show that one of the proposed methods produced more comfortable 3D images to viewers than the others.

A HIGH PRECISION CAMERA OPERATING PARAMETER MEASUREMENT SYSTEM AND ITS APPLICATION TO IMAGE MOTION INFERRING

  • Wentao-Zheng;Yoshiaki-Shishikui;Yasuaki-Kanatsugu;Yutaka-Tanaka
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.77-82
    • /
    • 1999
  • Information about camera operating such as zoom, focus, pan, tilt and tracking is useful not only for efficient video coding, but also for content-based video representation. A camera operating parameter measurement system designed specifically for these applications is therefore developed. This system, implemented in real time and synchronized with the video signal, measures the precise camera operating parameters. We calibrated the camera lens using a camera model that accounts for redial lens distortion. The system is then applied to infer image motion from pan and tilt operating parameters. The experimental results show that the inferred motion coincides with the actual motion very well, with an error of less than 0.5 pixel even for large motion up to 80 pixels.

Resolution improvement of 3D images in plane-based computational integral imaging reconstruction technique (평면기반 컴퓨터 집적 영상 재생 방법에서 3차원 영상의 해상도 개선)

  • Shin, Dong-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1944-1949
    • /
    • 2007
  • In this paper, a new plane-based computational reconstruction technique for three-dimensional (3D) objects in 3D internal imaging based on a lens model is proposed. For the proposed technique, computational experiments have been carried out for various test images. Resolution of the reconstructed images is analyzed and compared with that obtained by the conventional technique. From experiments, it is shown that the resolution of a 3-D reconstructed image was improved by using the proposed technique.

Design of Optical Pickup Actuator (광 디스크 드라이브의 픽업 액츄에이터 설계)

  • 조유호;조석환;오재견;최영석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.635-639
    • /
    • 1997
  • In order to design a system a process or plant must be put into a mathematical form for analysis and evaluation, and an appropriate controller must be designed to attain the desired system response. In this paper, the mathematical model for an optical pickup actuator is proposed and an H .inf. controller is employed to obtain the optimal focusing/tracking servo system behavior. Simulation and experiments are carried out to verify the performance of the proposed model.

  • PDF

Analysis on the Depressing Force to the Cornea by Fitted Spherical Contact Lens (구면 콘택트렌즈의 피팅에 따른 각막 부착력 해석)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.97-106
    • /
    • 2011
  • Purpose: This review article was written to theoretically compare the depressing force (pressure, adhesion) to the cornea between when the spherical lenses were being tightly and flat fitted. Methods: Mathematical equations and their numerical solution programs (model) were formulated to calculate the depressing (adhesion) force to the cornea by both the tightly and flat fitted contact lenses. Based on this proposed model the effects of parameters characterizing a contact lens such as BCs, diameters, edge shape and corneal shape (ratio of long and short corneal axis, p) on the depressing force to the cornea were predicted/analyzed in both tightly and flat fitting regimes. Results: Corneal adhesion increased as the corneal p-value increased. Adhesion increase caused by the increased p-value was much larger in flat fitted case than in tight fitted one. Corneal adhesion reduced abruptly as the BC increased in flat fitting regimes while the adhesion rise was insignificant in tight fitting ones. Reduction in corneal adhesion due to lens-size increase was predicted to be insignificant in both tight and flat fitting regimes. Both the lens edge shape (edge angle) and thickness were relevant only in tight fitting regime. Corneal adhesion increased as the increased with tight-fitted lenses. As the thickness of tight fitted lenses increased, corneal adhesion inversely decreased. Conclusions: The two most significantly affecting the depressing force to cornea were found to be the degree of corneal bending toward the periphery and the BCs of lenses.

The evaluation of lens absorbed dose according to the Optimold for whole brain radiation therapy (전뇌 방사선치료 시 Optimold에 따른 수정체의 흡수선량 평가)

  • Yang, Yong Mo;Park, Byoung Suk;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 2014
  • Purpose : In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. Materials and Methods : In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made ??up to 5mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. Results : When there was the Optimold mask in the eyeball part, it was measured at $10.2cGy{\pm}1.5$ in the simulation therapy, and at $24.8cGy{\pm}2.7$ in the treatment, and when the Optimold mask was removed in the eye part, it was measured at $12.9cGy{\pm}2.2$ in the simulation therapy, and at $17.6cGy{\pm}1.5$ in the treatment. Conclusion : In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3 cGy in the simulation therapy and was reduced approximately 7 cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause cataracts and side effects was considered to be reduced due to decrease of the absorbed dose to the eye lens which had the high sensitivity on the radiation.

Numerical Analysis of Cyclic Deformation of Polymer Foam Film Using Stretched Truncated Octahedron Model (모서리가 제거된 팔면체 인장모델을 이용한 다공성 폴리머 박막의 반복변형거동 수치해석)

  • Yoo, Ui-Kyung;Lee, Young-Seog
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.3
    • /
    • pp.104-110
    • /
    • 2010
  • Cyclic deformations of polymer foam film are simulated using the finite element method. Material of polymer foam film is polypropylene (PP). The calculated polymer foam film is micro-scale thin film has cellular structure. The polymer foam film is used in ferro-electret applications. The polymer foam film is idealized to one cell structure as lens shaped stretched truncated octahedron model. Cyclic deformation is performed by uniaxial stretching. Stretching direction is perpendicular to plane of cellular film. Various cyclic strain amplitudes, pore wall thicknesses, pore shape are investigated to find deformation tendency of cellular structure. Consequently, cellular structure has various macroscopic stresses on cyclic deformation with various pore thickness and pore shape.

Exploring Knowledge Processing in a Social Complex Adaptive Organization : Wikipedia through the Lens of the LIFE Model

  • Faucher, Jean-Baptiste P.L.;Everett, Andre M.;Lawson, Rob
    • Journal of Information Technology Applications and Management
    • /
    • v.18 no.1
    • /
    • pp.15-39
    • /
    • 2011
  • A deeper understanding of how organizations behave as social complex adaptive systems is needed. In this paper we demonstrate how the Leadership Invigorating Flows of Energies model can help with this understanding. The model highlights the role of emergent leadership as a force encouraging the creation, diffusion, and utilization of knowledge through self-organizing mechanisms. We illustrate our approach by examining Wikipedia and show how it can be described as a social CAS. Our analysis of Wikipedia describes how emerging intrapreneurship behaviors result in dynamic flows of knowledge and self-organizing feedback mechanisms across the organization. We provide implications for organization studies and present evidence to support claims made by advocates of complexity theory. We conclude by proposing that Wikipedia can be seen as a new form of organization, and finish with a brief note highlighting a possible way forward.