• Title/Summary/Keyword: Lens diameter

Search Result 170, Processing Time 0.027 seconds

PROTOTYPE OF HIGH RESOLUTION 3D DISPLAY USING TWO LENS ARRAYS AND DEPTH SAMPLING

  • Takeichi, Akira;Yendo, Tomohiro;Tanimoto, Masayuki;Fujii, Toshiaki
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.557-561
    • /
    • 2009
  • This paper presents a prototype of high resolution 3D display with a new principle. We have proposed a new 3D display which has the features of both Integral Imaging (II) and volumetric display. The proposed display consists of two lens arrays and a thin volumetric display. When the viewer watches a thin volumetric display through two lens array, he can perceive a thick 3D image. In other words the two lens arrays can play a role of a convex lens which has a large diameter as a amplification of a depth. The advantage of the proposed display is that it has higher resolution than II and it is smaller than volumetric display with a large convex lens. In this paper, we show a detail of a prototype 3D display. We took various errors into consideration when we simulated 3D display and we found suitable lenses parameter from the simulation result. Then we confirm that the prototype will be able to reconstruct 3D images.

  • PDF

Research on Fabrication of Silicon Lens for Optical Communication by Photolithography Process (포토리소그래피를 통한 광통신용 실리콘 렌즈 제작 및 특성 연구)

  • Park, Junseong;Lee, Daejang;Rho, Hokyun;Kim, Sunggeun;Heo, Jaeyeong;Ryu, Sangwan;Kang, Sung-Ju;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.2
    • /
    • pp.35-39
    • /
    • 2018
  • In order to improve the coupling efficiency, a collimator lens that collects the light emitted from the laser diode at a wide angle to the core of the optical fiber is essential. Glass mold method using a mold is widely used as a collimator lens currently used. Although this method is inexpensive to produce, it is difficult to form precisely and quality problems such as spherical aberration. In this study, the precision of surface processing was improved by replacing the existing glass mold method with the semiconductor process, and the material of the lens was changed to silicon suitable for the semiconductor process. The semiconductor process consists of a photolithography process using PR and a dry etching process using plasma. The optical coupling efficiency was measured using an ultra-precision alignment system for the evaluation of the optical characteristics of the silicon lens. As a result, the optical coupling efficiency was 50% when the lens diameter was $220{\mu}m$, and the optical coupling property was 5% or less with respect to the maximum optical coupling efficiency in the lens diameter range of $210-240{\mu}m$.

Model on the Contact Lens Movement from Eye-lid Blinking (순목 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.145-159
    • /
    • 2004
  • A mathematical model and its computer solution program were proposed to analyze the motion of contact lenses which are being subject to lid-blinking. The equation was derived by incorporating an acceleration induced lid's force exerting on the contact lens, the viscous damping resistance in the tear layer beneath the lens and the sliding frictional force between the lid and the contact lens surface into the formulation of differential equation describing the vibration. The model predicts the time-dependent displacement from the equilibrium postion during/after the blinking. During the blinking, as the time for the completion of one cycle of blinking decreases the off-the-equilibrium displacement of contact lens increases while the decrease of diameter in the contact cause the opposite effect. It is found that lid pressure exerting on the lens cause an insignificant lens displacement from the equilibrium position. After blinking the frequency of damped oscillation of contact lens decreases as the diameter of lens increases, due to the incresed surface while the reduced blinking time does not cause a significant frequency change. This is because that driving force for the contact lens movement posterior to blinking is the capillary-induced force not the lid force.

  • PDF

The effect analysis of birefringence of plastic f$\heta$ Iens on the beam diameter (플라스틱 f$\heta$렌즈의 복굴절이 결상빔경에 미치는 영향분석)

  • 임천석
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.73-79
    • /
    • 2000
  • We measure a beam diameter of scan and sub-scan direction of LSD (Laser Scanning Urnt) which uses $fheta$ lens produced by injecLion molding method as a scanning lens. While the measured beam diameter in scan direction, which is $62muextrm{m}$ to $68\mu\textrm{m}$, shows similar size comparing to the design beam diameter, the sub-scan beam diameter shows sIzable beam diameter deviation as much as 37 11m ranging from $78\mu\textrm{m}$ to $115\mu\textrm{m}$. Injection molding lens has the surface figure error due to the shrinkage III the cooling time and the internal distortion (birefringence) due to the uneven cooling conditIOn so that these bring about wavefront aberration (i.e., the enlargement of beam size), and are eventually expre~sed as the deterioration of the pdnting image. In this paper. we first measure and analyze beam diameter, birefringence (polanzation ratio), and asphedcal figure error of mIens in order to know the principle cause of the beam diameter deviation in sub-scan directIOn. And Lhen. through the analysis of a designed depth of focus and a calculated field curvature (imaging position of the optical axis directIon) using the above figure elTor data, we know Lhat the birefringence IS the main factor of sizable beam diameter deVIation in sub-scan direction. ction.

  • PDF

Optical Design of Gradient-Index Objective for Optical Pickup (광 Pickup 용 Gradient-Index 대물렌즈 설계)

  • Park, In-Kyu;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.256-263
    • /
    • 2007
  • High NA objective design by using SELFOC materials was studied, and two kinds of objective for optical pick-up were designed. The SELFOC materials have radial gradient index distribution, and it gives additional degree of freedom in optical design. Therefore, we expect that optical design of high NA objective without aspheric surface will be possible. In this study, the variation of ms spot diameter was investigated as a function of quadratic constant and refractive index on axis for various combinations of axial thickness and entrance pupil diameter. For the survey, Code V was used for optimization and evaluation of the objective lenses. The result suggested that larger quadratic constant and higher refractive index on axis could give us better imaging performance for all combinations of axial thickness and pupil diameter. Based on the survey, we designed high NA objectives for DVR. There were two kinds of design solution consisting two spherical SELFOC lenses. The solution I had positive-positive lens configuration with short over-all-length, but it had poor off-axial performance compared with the solution II. The solution II had negative-positive lens configuration with good off-axial imaging performance. But the solution II had some disadvantages, long over-all-length and large diameter of the second lens.

Analysis of IR lens mounting with elastomer (밀봉재를 이용한 적외선 렌즈 마운팅 분석)

  • 김연수;김현숙;최세철;김창우
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.460-462
    • /
    • 2001
  • We have analyzed the characteristics of IR lens mounting with elastomer and applied the results to the mounting of a silicon lens with diameter 117 mm which is the objective of a thermal imaging system. The elastomer, the 577 primerless silicone adhesive (Dow Corning Co.) which is heat cure type, and the mount material, A16061 are used for our analysis. Theoretical analysis gives the result that the space between lens and mount is required to be more than 250 ${\mu}{\textrm}{m}$ under the operational temperature conditions of -40~+6$0^{\circ}C$.

  • PDF

Solid Immersion Lens Microscope for Spectroscopy of Nanostructure Materials

  • Yim, Sang-Youp;Kim, Joon-Heon;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.78-81
    • /
    • 2011
  • We demonstrate a high-spatial-resolution imaging and spectroscopy tool using a solid immersion lens (SIL), a hemispherical lens made of high refractive index glass (n ~2). Photoluminescence (PL) images of single CdSe nanocrystals confirm a numerical aperture enhancement factor of ~2, close to the refractive index of the SIL. In particular, a bare-eye observation of PL signals emitted by single nanocrystals with ${\sim}10\;{\mu}m^{-2}$ densities was possible over an ${\sim}30\;{\mu}m$ diameter region. In addition, the PL spectra of single CdSe nanocrystals were successfully measured at room temperature. Thus, this SIL microscope ensures a simple but powerful method for nanostructure spectroscopy.

Changes of Lens Morphology and TBUT by Dehydration of Soft Contact Lens (소프트콘택트렌즈 건조로 인한 렌즈 형태 및 TBUT의 변화)

  • Park, Mijung;Lee, Yu-Na;Kang, Kyu Eun;Lee, Min Ha
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Purpose: This study was performed to evaluate the changes of lens morphology and tear stability during wearing soft contact lenses (SCLs) which were kept in drying condition like dry eye or became to be dried due to heedless care. Method: SCLs having different water content, thickness or material were rehydrated after being dehydrated artificially 2 or 4 times, and estimated their diameter and radius. Furthermore, the changes of tear film break-up time (TBUT) during SCL wearing were also measured. Result: Due to the dryness, the diameter of both 70% water content SCL and 59% water content SCL decreased, but the decrement was larger in 59% water content SCL. The more 59% water content SCL was dehydrated, the more its radius changed. However, the radius of 70% water content SCL did not change by 2 times dehydration and increased greatly by 4 times dehydration. The reduction of diameter of -1.00 D SCL was greater than that of -9.00 D SCL. Moreover, the radius of -1.00 D SCL increased depending on the frequency of dehydration but that of -9.00 D SCL did not changed. The diameter and radius changes of lotrafilcon B, silicone hydrogel lens, were less than those of hilafilcon B, copolymer of HEMA and N-vinyl pyrrolidone. TBUT during wearing SCLs decreased by wearing dehydrated SCLs. Conclusion: The diameter and radius of dehydrated SCLs as well as TBUT during wearing them were changed in spite of rehydration, which would be the important cause of uncomfortable feeling when people wore dehydrated SCL. The changes of SCL morphology and TBUT differed according to the water content, lens thickness and material.

  • PDF

Morphogenesis of the Eye of Brown Croaker (Miichthys miiuy)

  • Park, In-Seok;Seol, Dong-Won;Cho, Sung-Hwoan;Song, Young-Chae;Choi, Hee-Jung;Noh, Choong-Hwan;Myoung, Jung-Goo;Kim, Jong-Man
    • Ocean and Polar Research
    • /
    • v.28 no.3
    • /
    • pp.287-290
    • /
    • 2006
  • Eye growth and lens diameter of brown croaker Miichthys miiuy were positively allometric between hatching and 180 days post-hatch (d.p.h.). Eye growth in relation to head length and head height was nearly isometric. Eyes were formed completely at 14 d.p.h. At this age, the eye has a crystalline lens, an optic nerve fiber layer, a ganglion cell layer, an inner plexiform layer, an inner nuclear layer, an outer plexiform layer, an outer nuclear layer, an outer limiting membrane, and a pigment epithelium. The essential demands that must be met by the retina in this species pertain to light sensitivity and spatial resolution.

Nondestructive Test of Optical Connector by Resonant Ultrasound Spectroscopy Method (공명초음파분광법에 의한 광컨넥터용 결합소자의 비파괴검사)

  • Kim, Sung-Hoon;Lee, Kil-Sung;Kim, Dong-Sik;Kim, Young-Nam;Jeong, Sang-Hwa;Yang, In-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.143-150
    • /
    • 2004
  • In this paper, resonant ultrasound spectroscopy(RUS) was used to determine the natural frequency of a ceramic ferrule and a ball lens. The ceramic ferrules are cylinderical shape with $\phi$ 2.56mm diameter and l0mm in length. Crack lengths of these ferrules are 10.40$\mu$m, 21.18$\mu$m and 32.35$\mu$m. The spherical ball lens was made of BK-7 glass, one's diameter in 2mm and 5mm. RUS system is consisted of spectrum analyzer, power amplifier, PZT sensor and support frame. The principle of RUS is that the mechanical resonant frequency of the materials depends on density and the coefficient of elasticity. Rus system is based on that given resonant frequency of the materials can be represented by the function of density and the coefficient of elasticity, and it is applied to excite specimen and to inspect the difference of natural frequency pattern between acceptable specimen and defective ones. Defect evaluation by RUS are performed to investigate the natural frequency measure of ferrule and ball lens.