• Title/Summary/Keyword: Lens containers

Search Result 6, Processing Time 0.021 seconds

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

In vitro cytotoxicity of Acanthamoeba spp. isolated from contact lens containers in Korea by crystal violet staining and LDH release assay

  • Shin, Ho-Joon;Cho, Myung-Soo;Jung, Suk-Yul;Kim, Hyung-Il;Im, Kyung-Il
    • Parasites, Hosts and Diseases
    • /
    • v.38 no.2
    • /
    • pp.99-102
    • /
    • 2000
  • In order to observe the cytotoxicity of Acanthamoeba spp., which were isolated from contact lens containers as ethiological agents for the probable amoebic keratitis in Korea, the crystal violet staining method and LDH release assay were carried out. In the crystal violet staining method, among eight contact lens container isolates, isolate 3 (Acanthauloeba KA/LS5) showed 83.6% and 81.8% of cytotoxicity, and isolate 7 (Acanthamoeba KA/LS37) showed 28.2% and 25.1% of cytotoxicity, in 1 mg/ml and 0.5 mg/ml Iysate treatments, respectively. Acanthamoeba cutbertsoni and A. healyi showed 84.0% and 82.8% of cytotoxicity. Similar results were observed in A. costellunii and A. hafchefti which showed 83.6% and 75.5% or cytotoxicity. Acanthamoeba roureba and A. polyphaga showed 9.0% and 1.7% of cytotoxicity. In the LDH release assay, isolate 3 (20.4%) showed higher cytotoxicity than other isolates in 1 mg/ml Iysate treatment. The results provide that at least isolate 3 has the cytotoxic effect against CHO cells and seems to be the pathogenic strain.

  • PDF

Microbial Contamination of Contact lens cases in multi - purpose solution care systems (다목적 용액을 사용하는 콘택트렌즈 관리체계에서 렌즈 보관용기의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2000
  • The microbial contamination rate of contact lens cases in multi-purpose solution(MPS) care systems of 80 asymptomatic soft contact lens wearers was investigated. In caring for their lenses 72 patients (90%) used chemical disinfection(include MPS), six patients(7%) used hydrogen peroxide, and two patients(3%) used heat. Fifty-nine percent of patients used MPS in their care systems. Of 80 contact lens cases, contamination was found in 68%(54) of cases. There is a significant relationship between the ages of lens cases and contamination: older cases being more frequently contaminated. Of the contaminated 31 lens cases(57%) in MPS care systems, four contact lens cases(13%) were contaminated by single organism, 15 cases(48%) by two kinds of organisms, and 12 cases(39%) by more than three kinds of organisms. Of the organisms that were contaminated lens cases, Pseudomonas. Serratia, Bacillus, E. coli and Aspergillus were frequently isolated. When considering the high contamination rate of soft contact lens cases in MPS care systems more effective and hygienical lens care system is important, especially frequent and regular disposal of lens cases may prove to prevent the build-up of microbial colonisation in containers.

  • PDF

Survey on Contact Lens Wear Status in Gyeonggido (경기도 지역 콘택트렌즈 착용실태 조사)

  • Song, Yun-Young;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.373-378
    • /
    • 2014
  • To investigate the wear status of contact lenses by analyzing care of contact lenses container and actual condition of people wearing contact lenses and in Gyeonggido. The results were based on a questionnaire survey of 200 people who are the students of the middle school, the high school and the college among the clients of opticians to purchase contact lenses for six months from January 2013 to July 2013. According to the poll, the highest number of those polled, 139 (55.16%) people, said they were wearing cosmetic color contact lenses. Female respondents and male respondents were in the proportion of 177 (88.5%) to 23 (11.5%), respectively. 37 people (18.5%) who responded said "yes" to the question of them sharing contact lenses and glasses. 103 people (51.5%) answered "no" to the question of regularly replacing their lens containers. 148 people (74%) answered "yes" to the question of having glasses in order to investigate contact lens wearers user rate of glasses. The highest number of respondents, 127 people (63.5%), said "middle school" was the first time that they wore contacts. Meanwhile, 65 people (43.92%) said they initiated wearing glasses at 4th-6th grades. It is considered that it is necessary using proper contact lenses suitable for the clients' eye health in order of vision correction, rather than for cosmetic purposes. The role of the optician is considered to be very important for the proper management of the appropriate contact lens hygiene and regular optical check-ups of the contact lens wearers.

Isoenzyme patterns and phylogenetic relationships in Acanthamoeba spp. isolated from contact lens containers in Korea

  • Shin, Ho-Joon;Cho, Myung-Soo;Kim, Han-jip;IM, Kyung-Il
    • Parasites, Hosts and Diseases
    • /
    • v.37 no.4
    • /
    • pp.229-236
    • /
    • 1999
  • In order to refer to the basic information regarding the identification of isolates obtained from a contact lens container in Korea, the isoelectric focusing gel electrophoresis was employed to compare the isoenzyme band patterns among Acanthamoeba spp. including eight isolates and the simple pairwise dissimilarity analysis was carried out. For an alkaline phosphate development, isolate 7 and Acanthamoeba polyphaga showed homologous band patterns, and isolates 1, 2, and 3 showed the same patterns. For lactate dehydrogenase, similar patterns were observed in isolates 2 and 3. Isolates 3 and 5 showed homologous band patterns for malate dehydrogenase and glucose phosphate isomerase. For hexokinase, isolates 4, 7, and A. hatchetti showed the same band patterns. In others, a considerable number of interstrain polymorphisms was observed in nine isoenzyme band patterns. In Acanthamoeba group II, genetic distances among isolates 1, 2, 3, 4, and 5 ranged from 0.104 to 0.200. In comparison to A. castellanii, A. hatchetti, and A. poIyphaga, genetic distances of isolates 7 and 8 were 0.254 and 0.219, respectively. In Acanthamoeba group III, including A. culbertsoni, A. healyi, and A. royreba, isolate 6 had genetic distances which ranged from 0.314 to 0.336. Finally, when comparing to the six reference Acanthamoeba, it was possible to classify isolates 1, 2, 3, 4, and 5, as genetically close-related species and as independent species group. Furthermore, isolates 6, 7 and 8 were identified as independent species as well.

  • PDF

Optical Sensor of Coplanar Structure Study and Design for Intravenous Solution Exhaustion Alarm System (수액 소진 알람시스템을 위한 동일평면형 광센서의 연구 및 제작)

  • Park, Hyo Soon;Kim, Tae Yun;Jung, Eui Sung;Seong, Ki Woong;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.113-118
    • /
    • 2015
  • Intravenous (IV) infusion set is one of the most common treatment methods applied to hospitalized patients. However, it is necessary to check the injection of IV solution in order to prevent patients from any possible medical injuries. In this paper, using the optical sensors to detect exhaustion of IV solution was proposed. The optical sensor is coplanar structure composed of LED and photodiode which is installed according to focal distance of the lens. These two elements detect exhaustion of IV solution at the desired point conveniently. Through the results of experiments using various wavelength of LED (R.G.B), the blue LED was selected to the optimum light source. The suggested optical sensor can detect exhaustion of IV solution by the differences in the amount of light which is caused by properties such as total reflection, refractive index and scattering. From the implementation, the detector is applicable to both containers of IV solution, glass bottle and plastic pack. And also the result shows apparent differences according to existence of IV solution even if the IV solution color and illumination were changed.