• Title/Summary/Keyword: Lens case

Search Result 300, Processing Time 0.039 seconds

A Study of Soft Contact Lens Wearer on Women College Students (여대생의 소프트 콘택트렌즈 착용자에 대한 연구)

  • Kim, Douk-Hoon;Yoo, Jae-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.187-192
    • /
    • 2000
  • The objective of this study was to investigate the problems of soft contact lens wear on the women college students. The results were as follows 1. Almost the purchase of soft contact lens was the optical shop. 2. Almost the motive of soft contact lens use was the discomfort of glasses wear. 3. Almost the good feeling of glasses wear was moderate degree. 4. On the main reason of exchange of contact lens, teens was contact lens damage and tweenths was lifespan of contact lens. 5. On the contact lens wearing time at one day, teens was over 10 hours and tweenths was from 7 hours to 10 hours. 6. On the contact care and treatment, teens was a lens washing and storage and tweenths was a lens washing and disinfectant. 7. On the main difficult of contact lens handling, teens was a lens separation in eye and disinfection of lens case and tweenths was a solution treatment and insertion of contact lens in the eye. 8. On the contact lens insertion in the eye, the most difficult item was hanging of the eyelid and fear thinking in teens and fear thinking in tweenths. 9. On the difficult in separate of contact lens wear, a most subjects were eye opening. 10. On the most inconvenient state in contact lens wearing, the subjects were eye redness, foreign body and eye pain. 11. On the advantage of contact lens wearing, teens was decrease in glasses side effects and twenties was a beauty.

  • PDF

Biosafety of the New Soft Contact Lens Materials in the Fibroblast L-929 Cell Line (흰쥐의 섬유아세포 L-929를 이용한 새로운 Soft Contact Lens 소재의 생물안전성 검증)

  • You, Young-Hyun;Nam, Joo-Hyeung;Kim, Bieong-Kil;Kim, Soon-Bok;Moon, Ik-Jae;Kim, Jong-Pil;Seu, Young-Bae
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • In this study, we polymerized new materials for soft contact lens using HEMA (2-hydroxyethyl methacrylate) which is the based-monomer of soft contact lens, EGDMA (ethylene glycol dimethacrylate) as cross linkage agent, and the new additives of monoester or di-ester derived from itaconic acid commercially produced by the fermentation of Asp. itaconicus. New polymer materials for soft contact lens were synthesized with the mixture of HEMA and mono- or diester at different ratios and presented to a good water content and oxygen transmissibility (Dk/L) values. In case of polymerization with HEMA and mono-ester (15%), the water content and oxygen transmissibility of contact lens were found to be good values at 57.6% and 28.5 Dk respectively. The mixture of HEMA and mono-ester is more excellent than HEMA/di-ester in the water content and oxygen transmissibility. The toxicity of new contact lens materials were confirmed in the fibroblast L-929 cell line using a agar overlay test and a growth inhibition test with the extract solution of contact lens.

Improvement of Color Temperature Uniformity of Integrated Optic Lens Type LED Packaged using Compression Molding Method (가압성형 방식을 사용한 렌즈 일체형 LED 패키지의 색온도 균일성 향상에 관한 연구)

  • Kim, Wan-Ho;Kang, Young-Rae;Jang, Min-Suk;Joo, Jae-Young;Song, Sang-Bin;Kim, Jae-Pil;Yeo, In-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • Optical characteristics including the view angle and color temperature uniformity of LED packages with an integrated lens fabricated by compression molding method are investigated according to lens shape, lens materials, and phosphor coating methods. Four types of lens shape are designed and their optical output power dependence on the refractive index of silicone encapsulant are evaluated. Also, spatial color temperature uniformities of packages fabricated with different phosphor coating methods-direct coating on a chip vs. uniformly mixed with silicone encapsulant- are compared at various view angles. As the result, it is found that phosphor coating method is more effective on color temperature uniformity than lens shape. The maximum color temperature difference of a package with direct coating of phosphor on a chip is 1,340K according to the view angle at the color temperature of 5,000K, and that of a package with uniformly mixed phosphor is 250K, which indicates 1,090K improvement of color uniformity for the latter case.

Protein Absorption and Characterization of Hydrogel Polymer Containing 2-Methacryloyloxyethyl Phosphorylcholine as Additive

  • Kim, Duck-Hyun;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.9 no.4
    • /
    • pp.249-254
    • /
    • 2016
  • This study evaluated the physical and optical characteristics of hydrophilic ophthalmic polymer with addition of 2-methacryloyloxyethyl phosphorylcholine in the basic hydrogel ophthalmic lens material, and in particular, the utility of 2-methacryloyloxyethyl phosphorylcholine as an ophthalmic contact lens material for ophthalmologic devices was investigated. In this study 2-methacryloyloxyethyl phosphorylcholine were used as additives. For the preparation of hydrogel lens 2-hydroxyethyl methacrylate, methyl methacrylate, acrylic acid and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. The physical properties of the produced polymers were measured as followings. The refractive index of 1.433~1.393, water content of 35.95~53.16%, contact angle of $70.6{\sim}51.24^{\circ}$, UVB transmittance of 81.2~82.4%, UV-B transmittance of 81.2~82.4% and visible transmittance of 91.4~92.2% were obtained. Also, in case of protein absorption, the measurement showed that absorbance of Reference and MPC-10 sample was 0.2598 and 0.2250 respectively. Based on the results of this study, ophthalmic lens material containing 2-methacryloyloxyethyl phosphorylcholine is expected to be used usefully as a material for high wettability and inhibitor of protein adsorption for ophthalmic hydrogel lens.

Aspherical Lens Design and Injection Mold Analysis Using Extracted Shape Information (형상정보 추출을 통한 비구면 렌즈 설계 및 성형해석에 관한 연구)

  • Song, K. H.;Kim, B. C.;Yoon, H. S.;Yang, J. K.;Kim, K. B.;Xiao, H.;Cho, M. W.
    • Transactions of Materials Processing
    • /
    • v.24 no.6
    • /
    • pp.437-442
    • /
    • 2015
  • The development of polishing technology has enabled the production of injection molds with high quality surfaces and shapes. For products such as mobile phones which require high quality performance the use of plastic materials has many constraints such as shrinkage and deflection. The purpose of the current research is to use reverse engineering in order to find and analyze the data of a selected aspherical lens and then creating a process to design an improved lens. Additionally, the improved lenses are subject to molding analysis. In order to solve this problem, the lens construction program, Zemax, was used to analyze and optimize performance. In the case of optimization, the object was to eliminate spherical aberration and to find good MTF data. The result of the optimization data was similar to the MTF data found from a random lens. Specific resin and analysis conditions were selected and CAD modeling was done to enhance the injection molding analysis.

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

The Comparison of Fluorescein Patterns between Spherical RGP Lens and Aspherical RGP Lens by Corneal Type and Astigmatic Degree (각막형상과 난시도에 따른 구면 RGP 렌즈와 비구면 RGP 렌즈의 플루레신 염색 패턴 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • Purpose: The change of alignment between RGP lens and cornea according to the lens design was investigated by comparing the areas of fluorescein pattern in central and peripheral regions analyzed by astigmatic degree and corneal type when spherical and aspherical RGP lenses fitted in alignment. Methods: The fluorescein patterns of 90 eyes (19-30 years, $25.12{\pm}3.52$) having with-the-rule astigmatism were analyzed after spherical and aspherical RGP lenses fitted in alignment. Then, their fluorescent areas in central and peripheral regions were calculated and compared for the quantitative evaluation. Results: The case showing concordant base curve between spherical and aspherical RGP lenses in alignment fitting was 72% however, the possibility to have same base curves between spherical and aspherical RGP lenses in alignment fitting was to be less in the case of symmetric bowtietyped cornea and high astigmatism. The fluorescent area in peripheral region of aspherical RGP lens in alignment fitting was smaller than it of spherical RGP lens. Peripheral fluorescent areas in both RGP lenses decreased according to the increase of astigmatic degree and peripheral area in symmetric bowtie-typed corea was smaller than round-typed cornea's peripheral area. In the case of same astigmatic degree, peripheral fluorescent area of aspherical RGP lens was smaller in both corneal types. Conclusions: The results above suggest the changing degree in the alignment between RGP lens and cornea can be varied according to lens design, corneal astigmatism and corneal type. Thus, the results obtained from the quantitative analysis of the alignment between lens design and cornea may be used as the basic information about the establishment of guidelines for RGP lens fitting, the development of proper lens design, and different tear volume in partial regions.

A Study on the Residual Astigmatism Appeared after Operating ICL Lens (ICL 렌즈 시술 후 나타나는 잔류난시에 대한 연구)

  • Kim, Dook-Hoon;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.155-160
    • /
    • 2008
  • Purpose: To develop a program for analyzing the condition of implanted ICL lenses in case the residual astigmatism appears after the implantation. Methods: From analyzing the measured residual astigmatism after operating ICL lens, we could induce formulas that produce the rotating angle and the corresponding MR prescription of the implanted ICL lens. Using the Delphi 6.0 language, we could develop a program by which we conveniently confirm, in the window screen visually, the rotating angle and the corresponding MR prescription of the implanted ICL lens calculated by these formulas. Results: We induced formulas that produce the rotating angle and the corresponding MR prescription of the implanted ICL lens by analyzing the measured residual astigmatism after operating ICL lens and developed a program which can analyze the condition of the implanted ICL lens. By this program we could easily analyze the condition of the implanted ICL lens. Conclusions: Judging from the results of applying this program to many clinical cases, we could conclude that this program is very effective in analyzing the condition of implanted ICL lenses.

  • PDF

THE CONTACT LENS RELATED CASE REPORTS IN PEDIATRIC POPULATION I -Congenital Cataract With Divergent Squint (콘택트렌즈에 연관된 소아집단 I 에서 증례 보고 -개산성 사시를 가지는 선천성 백내장)

  • Chen, Ai-Hong;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.75-79
    • /
    • 2004
  • Some ocular complications were connected to the contamination by the contact lens related. Especially the most cause of ocular complications was a microorganism from several processing of infections. Therefore the patients stopped the contact lens wear immediately by the side effects of ocular pathology. We had analyzed the microorganism from the laboratory. It was identified as mixed growth of the Chryseamonas meningosepticum and Enterobacter sp.

  • PDF

New Design Method of Stable Lens System Against Chromatic Variation Based on Paraxial Ray Tracing

  • Lee, Jong-Ung
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.23-30
    • /
    • 2020
  • This paper presents a new method for designing a lens system stable against chromatic variation at a specified wavelength. Conventional lenses are corrected for chromatic aberration, but the new method suppresses chromatic changes of the marginal ray in the image-side. By doing so, paraxial properties of the lens system are stabilized against chromatic variation. Since the new method is based on paraxial ray tracing, the stabilizing conditions against chromatic variation are given by recurrence formulas. However, there is an analytic solution for the case of a cemented doublet in the air. A stable doublet at 405 nm wavelength is designed and analyzed.