• 제목/요약/키워드: Lens case

검색결과 300건 처리시간 0.025초

여대생의 콘택트렌즈 착용 및 관리 실태에 따른 안구건조증과 눈 피로 (Dry Eye Syndrome and Ocular Fatigue according to the Status of Contact Lens Wearing and Management among Female University Students)

  • 허선;김계하
    • 지역사회간호학회지
    • /
    • 제25권4호
    • /
    • pp.259-269
    • /
    • 2014
  • Purpose: The purpose of this study was to examine dry eye syndrome and ocular fatigue according to the status of contact lens wearing and management among female university students. Methods: The subjects were 195 female university students wearing contact lenses. Ocular Surface Disease Index (OSDI) and Virtual Reality Symptom Questionnaire (VRSQ) were used to determine the level of dry eye syndrome and ocular fatigue. The SPSS/WIN 21.0 program was used for analysis of data. Results: Significant differences in the level of dry eye syndrome were observed according to the period of case solution change (F=3.36, p=.037) and the reasons for the change of lens (F=4.56, p=.004). In ocular fatigue, significant differences were observed according to the price of lens (F=3.53, p=.031), rinse in storing lens in a case (t=-2.57, p=.011), and learning about contact lens (t=-2.01, p=.046). A significant positive correlation was observed between dry eye syndrome and ocular fatigue in the subjects. Conclusion: The results of this study show that some subjects have problems in wearing and management of contact lenses. Therefore, an education program related to contact lenses should be provided to contact lens wearers to improve the status of wearing and management of contact lenses.

The First Acanthamoeba keratitis Case of Non-Contact Lens Wearer with HIV Infection in Thailand

  • Tananuvat, Napaporn;Techajongjintana, Natnaree;Somboon, Pradya;Wannasan, Anchalee
    • Parasites, Hosts and Diseases
    • /
    • 제57권5호
    • /
    • pp.505-511
    • /
    • 2019
  • Acanthamoeba keratitis (AK) is a rare sight-threatening corneal infection, often reporting from contact lens wearers. An asymptomatic human immunodeficiency virus (HIV)-infected Thai male without history of contact lens use complained foreign body sensation at his left eye during motorbike riding. He had neither specific keratitis symptoms nor common drugs responding, which contributed to delayed diagnosis. By corneal re-scraping, Acanthamoeba-like cysts were detected by calcofluor white staining and agar culture. The etiological agent obtained from the culture was molecularly confirmed by Acanthamoeba spp.-specific PCR, followed by DNA sequencing. The results from BLAST and phylogenetic analysis based on the DNA sequences, revealed that the pathogen was Acanthamoeba T4, the major genotype most frequently reported from clinical isolates. The infection was successfully treated with polyhexamethylene biguanide resulting in corneal scar. This appears the first reported AK case from a non-contact lens wearer with HIV infection in Thailand. Although AK is sporadic in developing countries, a role of free-living Acanthamoeba as an opportunistic pathogen should not be neglected. The report would increase awareness of AK, especially in the case presenting unspecific keratitis symptoms without clinical response to empirical antimicrobial therapy.

등가렌즈의 해석적인 변환방법에 대한 연구 (A Study for an Analytic Conversion between Equivalent Lenses)

  • 이종웅
    • 한국광학회지
    • /
    • 제23권1호
    • /
    • pp.17-22
    • /
    • 2012
  • 등가렌즈는 전체굴절능과 주변광선에 대한 근축광학적 특성은 같지만 축상두께가 다른 렌즈이다. 이 연구에서는 두꺼운 렌즈를 등가렌즈로 변환하는 해석적인 방법에 대하여 연구하였고, 변환조건이 2차방정식의 해로서 주어짐을 보였다. 모든 두꺼운 렌즈는 유일해인 경우를 제외하면 이 2차방정식의 두 실근중의 하나이기 때문에 반드시 공액해가 1개 존재한다. 이 공액해는 축성 두께와 근축광학적 특성은 같지만 모양과 수차특성은 다르다. 예제 렌즈의 등가렌즈 변환을 통하여 등가렌즈와 이에 대응하는 공액해의 특성을 살펴보았다.

ESPI를 이용한 구면 안경렌즈의 면외 변형 측정 (Out-of-plane Deformation Measurement of Spherical Glasses Lens Using ESPI)

  • 양승필;김경석;장호섭;김현민
    • 한국안광학회지
    • /
    • 제12권4호
    • /
    • pp.77-81
    • /
    • 2007
  • 구면 렌즈는 굴절력에 따라 크게 (+)디옵터와 (-)디옵터 렌즈로 구분할 수 있다. 렌즈에 가해지는 외력에 의해 발생되는 변형은 디옵터의 증가 또는 감소에 따라 다르게 발생된다. 본 논문에서는 수년간 광계측 분야에서 널리 사용되고 있는 ESPI를 이용하여 렌즈에 발생되는 변형을 정량적으로 측정 하였다. ESPI(Electronic Speckle Pattern Interferometry: ESPI)는 빛의 가간섭성을 이용하여 대상물의 변형을 비접촉으로 정밀하게 측정할 수 있다는 장점을 지니고 있다. 실험은 총 16종의 플라스틱 안경 렌즈를 대상으로 수행 하였다. 동일한 변위를 주었을 때, (+)렌즈는 디옵터가 증가함에 따라 변형량이 감소하고, (-)렌즈의 경우 (+)디옵터 렌즈와는 반대로 디옵터가 감소함에 따라 변형량이 증가한다는 것을 확인 하였다. 또한 (+)디옵터 렌즈가 (-)디옵터 렌즈에 비해 상대적으로 변형량이 적게 발생한 사실을 알 수 있었다. 따라서 본 논문의 결과는 다양한 렌즈에 외부 변위가 가해지는 경우 렌즈의 변형에 의한 광학적 결함 등을 정량적으로 측정 할 수 있는 가능성을 제시하고 렌즈 산업 분야에 다양하게 응용 될 것으로 기대된다.

  • PDF

순차이송 GMP 방식용 유리렌즈 금형의 열응력에 관한 연구 (A Study on the Thermal Stresses of the Glass Lens Mold Using in Progressive GMP Process)

  • 장성호;이영민;신광호;윤길상;정우철;정태성;허영무
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2007
  • To prevent the damage of glass lens molds and deterioration of glass lenses using in progressive GMP process, a thermal stress and a deformation of the glass lens molds at forming temperature should be considered in the design step. In this study, as a fundamental study to develop a multi cavity mold used in an aspheric glass lens molding, a heat transfer and a thermal stress analysis were carried out for the case of one cavity glass lens mold used in progressive GMP process. Finally, using analysis results, we estimated the thermal stress in a glass lens mold and predicted a modified height of guide ring that determines the forming height of a glass lens.

  • PDF

유체 렌즈의 초점과 유동 인자의 상관관계에 대한 수치해석 (Numerical study on the relation between flow parameters and the focal point of fluidic lens)

  • ;김대겸
    • 한국가시화정보학회지
    • /
    • 제17권2호
    • /
    • pp.90-95
    • /
    • 2019
  • In the present work, the effect of flow parameters such as volume flow rate on focal point of fluidic micro lens is investigated numerically. ANSYS Fluent is used for simulations, and the flow parameters and number of simulations are determined using the space filling method of design of experiment (DOE). Having determined the location of interfaces between fluids inside the micro lens which acts as the lens curvature, a ray tracking simulation on each case is performed using COMSOL Multiphysics to determine the focal point for each lens. These data are then used to provide a relation between flow parameters and the focal point of the lens.

안경원의 시험착용 콘택트렌즈 및 관리용품 관리 실태 (The Actual Management State of Trial Contact Lenses and Lens Care Products in Local Optical Shops)

  • 박미정;이운정;김소라
    • 한국안광학회지
    • /
    • 제16권4호
    • /
    • pp.391-401
    • /
    • 2011
  • 목적: 국내 안경원의 시험착용렌즈와 관리용품의 관리 실태를 조사하고 분석함으로써 관리 소홀로 인하여 유발될 수 있는 사고의 위험성을 낮추고자 하였다. 방법: 콘택트렌즈 착용자들을 대상으로 시험착용렌즈의 착용 시 느끼는 점을 설문 조사하였으며, 콘택트렌즈를 취급하는 안경원의 안경사를 대상으로 시험착용 콘택트렌즈인 미용렌즈와 RGP 렌즈 그리고 렌즈 관리용품의 관리 실태를 설문 조사하였다. 결과: 시험착용 미용렌즈와 RGP 렌즈의 경우는 98% 이상의 안경사들이 렌즈 착용 전후 세척을 실시하고 있기 때문에 소비자들은 렌즈의 위생 상태를 신뢰하고 있는 것으로 나타났다. 시험착용 미용렌즈의 착용 전 세척은 생리식염수 38.5%, 전용 다목적 용액 40.5%, 생리식염수와 다목적 용액의 병행 사용 21%로 이루어지고 있었으며, 착용 후 세척은 생리식염수 13%, 다목적 용액 75%, 생리식염수와 다목적 용액의 병행이 12%로 이루어지고 있었다. 반면 시험착용 RGP 렌즈의 경우는 착용 전 세척에는 생리식염수가 28.5%, 전용 다목적 용액이 38.5%, 식염수와 다목적 용액 병행이 33%로 나타났으며, 착용 후 보관전 세척은 식염수가 2.5%, 다목적 용액이 70%, 다목적 용액 세척 후 식염수 세척은 27.5%를 차지하여 비교적 세척이 잘 이루어지고 있었다. 안경원에서 시험착용 미용렌즈의 세척은 주로 열흘에서 1개월을 주기로 이루어지는 것으로 나타냈고, 보관용기의 세척은 1 개월을 주기로 이루어졌다. 시험착용 RGP 렌즈의 세척주기는 주로 1개월 또는 2~3개월이었다. 시험착용렌즈 보관용기의 경우는 계면활성제를 이용하여 세척한 후 찬물로 헹구는 경우가 75% 이상으로 나타났다. 관리용품인 생리식염수의 보관기간은 주로 일주일로 나타났고, 다목적 용액의 보관기간은 주로 1개월이나 2~3개월로 나타나 안경원에서 렌즈 관리용액의 보관기간은 비교적 잘 지켜지고 있는 것으로 조사되었다. 결론: 안경원에서의 시험착용렌즈 및 관련 관리용품의 관리는 전반적으로 양호하게 이루지고 있었으나 생리식염수를 이용한 세척을 지양하고, 2주 이내의 세척주기와 뜨거운 물로의 렌즈 보관용기 헹굼이 추가적으로 강화된다면 국민의 눈 건강 증진과 더불어 안경사에 대한 더 높은 신뢰성 구축이 가능할 것이다.

홀더종류에 따른 소프트 콘택트렌즈의 정점굴절력 측정의 정확도 분석 (Analysis of Vertex Refractive Power Accuracy of Soft Contact Lens with Holder Type)

  • 이민제;성아영
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.105-115
    • /
    • 2015
  • 목적: 본 연구는 안경렌즈홀더와 콘택트렌즈홀더를 사용하여 다양한 디옵터와 함수율을 가진 소프트 콘택트렌즈의 굴절력을 측정하고 정확도를 평가하여 그 차이를 비교하였다. 방법: 실험에 사용한 소프트 콘택트렌즈의 함수율은 각각 38%, 43% 및 58%이었으며, 굴절력에 따라 -3.000 D, -7.000 D 및 -10.000 D로 분류하여 각각 실험하였다. 또한 망원경식 렌즈미터를 사용하여 안경렌즈홀더 및 콘택트렌즈홀더로 각각의 정점굴절력을 측정하여 정확도를 분석하였다. 결과: 안경렌즈홀더를 사용한 경우 -3.0000 D는 -3.3273 D로 측정되었으며, -7.0000 D는 -7.1306 D, -10.0000 D는 -10.2944D로 각각 측정되었다. 또한 콘택트렌즈홀더를 사용한 경우 -3.0000 D는 -3.1060 D로 측정되었으며, -7.0000 D는 -7.0028 D, -10.0000 D는 -10.2611 D로 각각 측정되었다. 모든 종류의 콘택트렌즈에서 콘택트렌즈홀더를 사용한 방법이 안경렌즈홀더를 사용한 방법보다 더 정확한 측정값을 나타내었다. 결론: 위 결과로 볼 때, 망원경식 렌즈미터를 사용한 소프트 콘택트렌즈의 굴절력 측정에 있어 콘택트렌즈홀더를 사용한 방법이 안경렌즈홀더를 사용한 방법보다 더 높은 정확도를 가진 것으로 판단된다.

소형 복사방식 순차제조 비구면 렌즈 제조시스템 개발 (Development of a Small Radiant Sequential Production System for Aspheric Lens)

  • 국금환;정준효
    • 한국정밀공학회지
    • /
    • 제27권12호
    • /
    • pp.67-74
    • /
    • 2010
  • The fabrication method of aspheric lens is changed from machining to press molding so as to improve the productivity. In the case of the press molding method, the temperature control of the molding die is most impotent, because the temperature of each molding die determines the quality of lens. But any practical method for direct measuring of the lens temperature and the die internal temperature is yet unknown. Besides, in the case of the press molding system in which the heating and pressing and cooing of a die is done at one work station, the cycle time for the system is yet too long. The paper shows an improved structure of radiant sequential system in which the heating and pressing and cooing of dies is done at individual work station so as to cut down the cycle time. To know the die internal temperature, numerical results are given using ANSYS. An experimental radiant sequential system is developed and tested. Finally, the Taguchi method is applied in order to optimize the setting conditions of individual work station.

ESPI를 이용한 안경용 렌즈의 열변형 측정 (Thermal Deformation Measurement Spherical Glasses Lens Using ESPI)

  • 김경석;장호섭;김현민;양승필
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.137-143
    • /
    • 2008
  • 안경용 구면 렌즈는 굴절력에 따라 (+)디옵터와 (-)디옵터 렌즈로 구분할 수 있다. 렌즈에 가해지는 외부 열원에 의해서 생기는 열변형은 디옵터의 종류에 따라 다르게 나타난다. 본 논문에서는 빛의 가간섭성을 이용하여 물체의 변형을 비접촉으로 정확하게 측정할 수 있는 전자처리 스페클법을 이용하여 렌즈에 발생되는 열변형을 정량적으로 측정하였다. 외부 열원에 의한 온도 분포의 측정은 실시간 비접촉으로 온도를 측정할 수 있는 적외선 열화상 카메라를 사용하였다. 실험은 총 14종의 플라스틱 상용 안경 렌즈를 대상으로 수행하였다. 동일한 온도차에서 (+)디옵터 렌즈의 경우에는 디옵터의 증가에 따라서 열변형량이 증가하였다. 반면에 (-)디옵터 렌즈는 디옵터의 증가와 관계없이 열변형량이 거의 선형적이었다. 또한 동일한 디옵터에서 (+)디옵터 렌즈의 열변형량이 (-)디옵터 렌즈의 열변형량 보다 작았다. 따라서 본 논문에서는 렌즈에 열이 가해지는 경우 렌즈의 열변형량을 정량적으로 측정할 수 있음을 확인하였다.