• 제목/요약/키워드: Length ratio of pile

검색결과 75건 처리시간 0.033초

Incremental filling ratio of pipe pile groups in sandy soil

  • Fattah, Mohammed Y.;Salim, Nahla M.;Al-Gharrawi, Asaad M.B.
    • Geomechanics and Engineering
    • /
    • 제15권1호
    • /
    • pp.695-710
    • /
    • 2018
  • Formation of a soil plug in an open-ended pile is a very important factor in determining the pile behavior both during driving and during static loading. The degree of soil plugging can be represented by the incremental filling ratio (IFR) which is defined as the change in the plug length to the change of the pile embedment length. The experimental tests carried out in this research contain 138 tests that are divided as follows: 36 tests for single pile, 36 tests for pile group ($2{\times}1$), 36 tests for pile group ($2{\times}2$) and 30 pile group ($2{\times}3$). All tubular piles were tested using the poorly graded sand from the city of Karbala in Iraq. The sand was prepared at three different densities using a raining technique. Different parameters are considered such as method of installation, relative density, removal of soil plug with respect to length of plug and pile length to diameter ratio. The soil plug is removed using a new device which is manufactured to remove the soil column inside open pipe piles group installed using driving and pressing device. The principle of soil plug removal depends on suction of sand inside the pile. It was concluded that the incremental filling ratio (IFR) is changed with the changing of soil state and method of installation. For driven pipe pile group, the average IFR for piles in loose is 18% and 19.5% for L/D=12 and 15, respectively, while the average of IFR for driven piles in dense sand is 30% and 20% for L/D=12 and L/D=15 respectively. For pressed method of pile installation, the average IFR for group is zero for loose and medium sand and about 5% for dense sand. The group capacity increases with the increase of IFR. For driven pile with length of 450 mm, the average IFR % is about 30.3% in dense sand, 14% in medium and 18.3% for loose sand while when the length of pile is 300 mm, the percentage equals to 20%, 17% and 19.5%, respectively.

Effects of pile geometry on bearing capacity of open-ended piles driven into sands

  • Kumara, Janaka J.;Kurashina, Takashi;Kikuchi, Yoshiaki
    • Geomechanics and Engineering
    • /
    • 제11권3호
    • /
    • pp.385-400
    • /
    • 2016
  • Bearing capacity of open-ended piles depends largely on inner frictional resistance, which is influenced by the degree of soil plugging. While a fully-plugged open-ended pile produces a bearing capacity similar to a closed-ended pile, fully coring (or unplugged) pile produces a much smaller bearing capacity. In general, open-ended piles are driven under partially-plugged mode. The formation of soil plug may depend on many factors, including wall thickness at the pile tip (or inner pile diameter), sleeve height of the thickened wall at the pile tip and relative density. In this paper, we studied the effects of wall thickness at the pile base and sleeve height of the thickened wall at the pile tip on bearing capacity using laboratory model tests. The tests were conducted on a medium dense sandy ground. The model piles with different tip thicknesses and sleeve heights of thickened wall at the pile tip were tested. The results were also discussed using the incremental filling ratio and plug length ratio, which are generally used to describe the degree of soil plugging. The results showed that the bearing capacity increases with tip thickness. The bearing capacity of piles of smaller sleeve length (e.g., ${\leq}1D$; D is pile outer diameter) was found to be dependent on the sleeve length, while it is independent on the sleeve length of greater than a 1D length. We also found that the soil plug height is dependent on wall thickness at the pile base. The results on the incremental filling ratio revealed that the thinner walled piles produce higher degree of soil plugging at greater penetration depths. The results also revealed that the soil plug height is dependent on sleeve length of up to 2D length and independent beyond a 2D length. The piles of a smaller sleeve length (e.g., ${\leq}1D$) produce higher degree of soil plugging at shallow penetration depths while the piles of a larger sleeve length (e.g., ${\geq}2D$) produce higher degree of soil plugging at greater penetration depths.

Velvet의 pile 길이가 촉감 및 물리적 특성에 미치는 영향 (The Effect of Pile Length on the Handle and Physical Properties of Velvet)

  • 장정애;류덕환
    • 한국의류학회지
    • /
    • 제19권3호
    • /
    • pp.471-482
    • /
    • 1995
  • Using the acetate velvet and viscose velvet whose pile lengths were sheared as 1.45, 1.55, 1 65, 1.75, 1.85, 1.90mm under the condition equating the weaving process of ground fabric, the conclusions were as follows through the results of the sensory assessments estimated by women students in our university and the physical properties, H. V and T. H. V obtained by KES-F system. 1. In the sensory assessments estimated by the method of paired comparison and ranking of samples, the longer pile length was, the more the hand values of smoothness, softness, thickness, heaviness increased on the whole. 2. The H V. and T. H. V. measured by KES-F system were as follows; Kohi increased to pile length 1.85mm and then decreased a little at 1.90mm. hummer increased as pile length was longer. Fukurami increased to pile length 1.75mm and then decreased gradually as pile length was longer. Total hand value increased gradually from 1. 45mm to 1.85mm, had the top value at 1.85mm, and then decreased a little at 1.90mm. 3. In the results of summarizing $\ulcorner$the physical properties correlated closely with the H. V obtained by sensory assessments$\lrcorner$ and tithe Physical properties correlated closely with the H. V. and T. H. V obtained by KES-F systems, it showed that all the sensory properties correlated closely with compressive energy, flexural rigidity, thickness, weight and pile ratio in the former and that the physical properties correlated closely with each H V and T. H. V were different in the latter. 4. It showed that factor 1 was related to compressive energy, thickness, weight, pile ratio, factor 2 was related to recovery energy, compressive resilience, compressive index, and factor 3 was related to compressive recovery ratio in the result of factor analysis. 5. In the multiple repression analysis, the expressions of all sensory properties had compressive ratio, frictional coefficient in the regression expressions of $\ulcorner$H. V. obtained by sensory assessments$\lrcorner$, while the expressions of each H. V. and different physical properties in the regression expressions of $\ulcorner$H. V. obtained by KES-F system$\lrcorner$.

  • PDF

단일 현장타설말뚝의 가상고정점 설계를 보완한 상부기둥-하부말뚝 최적 길이비 분석 (Analysis of Optimized Column-pile Length Ratio for Supplementing Virtual Fixed Point Design of Bent Pile Structures)

  • 정상섬;김재영
    • 대한토목학회논문집
    • /
    • 제33권5호
    • /
    • pp.1915-1933
    • /
    • 2013
  • 본 연구에서는 단일 현장타설말뚝의 가상고정점을 고려한 해석과 기둥-말뚝을 3차원 전체 모델링한 해석을 비교 분석하여 가상고정점 해석법의 적정성을 평가하였다. 또한, 말뚝 길이, 기둥 및 말뚝 직경, 철근비, 지반조건 등 주요 영향인자에 따라 단일 현장타설말뚝의 거동 평가를 수행하였으며, 이를 통해 가상고정점 해석을 보완한 최적 기둥-말뚝 길이비를 분석하였다. 본 연구결과, 가상고정점을 고려한 해석은 전체 모델링한 해석과 비교하여 침하량과 수평변위를 작게 예측하였으나, 반대로 축력과 휨모멘트는 가상고정점을 고려한 해석에서 크게 나타났다. 따라서 가상고정점을 통한 해석법은 실제 구조물 거동과 다른 단부조건으로 단일 현장타설말뚝의 정확한 거동을 파악하기엔 무리가 있음을 알 수 있었으며, 이에 단일 현장타설말뚝의 정확한 설계를 위해서는 3차원 전체 모델링한 해석이 필요한 것으로 판단되었다. 또한 본 연구에서는 하부 말뚝 길이와 말뚝의 허용 수평변위 관계를 통해 최적 기둥-말뚝 길이비를 분석하였으며, 이를 통해 가상고정점을 고려한 설계를 다소 보완한 경제적이고 개선된 단일 현장타설말뚝 설계를 수행할 수 있을 것으로 기대되었다.

단일형 현장타설말뚝의 소성힌지를 고려한 최적설계법 제안 (Analysis of Plastic Hinge of Pile-Bent Structure with Varying Pile Diameters)

  • 안상용;정상섬;김재영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.349-356
    • /
    • 2010
  • In this study, a new design method of pile bent structure considering plastic hinge was proposed on the basis of the beam-column model. Based on the analysis results, it is found that the positioning of plastic hinge on the pile bent structure was influenced by nonlinear behavior of material and p-$\Delta$ effect. Moreover, concrete cracking began to occur at the joint section between the pile and column in case of pile bent structure with different cross-sections. The plastic hinge can be developed on the pile bent structure when large displacement was occurred, and pile bent structures can be maintained well only if it is developed on the column part. Therefore, in this study, the optimized cross-section ratio between column and pile was analyzed to induce the plastic hinge at the joint section between the pile and column. Based on this, the optimized diameter ratio of pile and column can be obtained below the inflection point of the bi-linear curve depending on the relations between column-pile diameter ratio($D_c/D_p$) and normalized lateral cracking load ratio($F/F_{Dc=Dp}$). And through this study, it is founded that in-depth limit($L_{As}$=0.4%) normalized by the pile length($L_P$) are proportionally decreased as the pile length($L_P/D_P$) increases up to $L_P/D_P$=17.5, and beyond that in-depth limit converges to a constant value. Finally, it is found that the proposed limit depth by taking into account the minimum concrete-steel ratio would be more economical design of the pile bent structure.

  • PDF

사질토 지반에서 시멘트밀크 주입비에 따른 매입말뚝의 수평지지력 (The Lateral Load Capacity of Bored-Precast Pile Depending on Injecting Ratio of Cement Milk in Sand)

  • 홍원표;윤중만
    • 한국지반신소재학회논문집
    • /
    • 제12권4호
    • /
    • pp.99-107
    • /
    • 2013
  • 매입말뚝의 수평저항 특성을 고찰하기 위하여 매입말뚝에 대한 수평재하시험을 실시하여 수평하중과 수평변위관계를 분석하였다. 말뚝수평재하시험은 시멘트 밀크가 말뚝매입길이의 50%, 70%, 100%로 주입된 6개의 말뚝에 대하여 실시하였다. 시멘트 밀크의 주입비(시멘트 밀크 주입길이/말뚝의 길이)는 매입말뚝의 수평변위, 항복하중, 수평지지력에 큰 영향을 미치는 것으로 나타났다. 시멘트 밀크의 주입비가 증가할수록 매입말뚝의 수평변위가 발생되기 시작하는 위치는 지표면에 가까워지며 말뚝의 수평변위는 감소한다. 그리고 말뚝의 수평지지력과 항복하중은 시멘트 밀크 주입비가 증가할 수록 크게 나타났다. 시멘트 밀크 주입비가 1인 매입말뚝의 항복하중과 극한수평지지력은 시멘트 밀크 주입비가 0.5인 경우보다 약 2~3배 정도 크게 나타났다.

모형실험에 의한 사질토 지반에서 단말뚝의 수평거동 특성 (Lateral Behavior Characteristics of Short Pile in Sands by Model Tests)

  • 김진복;박종운;한대환;권오균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.366-376
    • /
    • 2008
  • The model tests of short pile with very small pile length/diameter(L/D) were performed in this paper. Varying the pile diameter, length, and the lateral loading point, the lateral resistance and behavior of very short pile were studied in this model tests. The experimental and analytical results are as follows. The lateral ultimate resistance of short pile in sands was the maximum at the point of h/L=0.75, regardless of pile length/diameter(L/D). As the pile diameter is larger, the lateral ultimate resistance of pile with L/D=1 decreases a little and the lateral resistance increases according to the ratio of pile length/diameter. As the lateral loads are acting on the pile, the displacement of pile head is maximum at the pile top of h/L=0, but minimum at the middle point of the pile. And if the loading point is under the middle of pile, the displacement of pile head occurs oposite in the loading direction, but its magnitude is very small.

  • PDF

사질토 지반에서 말뚝의 수평거동 (Lateral Behavior of Sin811e and Group Piles in Sand)

  • 김영수;김병탁
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.3-44
    • /
    • 1999
  • This paper discusses the lateral behavior of single and group piles in homogeneous and non-homogeneous(two layered) soil. In the single pile, the model tests were conducted to investigate the effects on ratio of lower layer height to embedded pile length, ratio of soil modules of upper layer to lower layer, boundary rendition of pile head and tip, embedded pile length, pile construction condition, ground condition with saturate and moisture state in Nak-Dong river sand. Also, in the group pile, the model tests were to investigate the effects on spacing-to-diameter ratio of pile, pile array, ratio of pile spacing, boundary condition of pile head and tip, eccentric load and ground condition. The maximum bending moment and deflection induced in active piles were found to be highly dependent on the relative density, pile construction condition, boundary condition of pile head and tip. Based on the results obtained, it was found that the decrease of lateral bearing capacity in saturated sand was in the range of 31% - 53% as compared with the case of dry sand. Also, in the group pile, a spacing-to-diameter of 6.0 seems to be large enough to eliminate the group effect for the case of relative density of 61.8%, and 32.8%, and then each pile in such a case behaves essentially the same as a single pile. In this study, the program is developed by using the modified Chang method which used p - y method and the exact solution of governing equation of pile and it can be used to calculate the deflection, bending moment and soil reaction with FDM in non-homogeneous soil. In comparing the modified Chang method with field test results, the predict results shows better agreement with measured results in field tests.

  • PDF

파일길이비와 암반층의 위치에 따른 마이크로파일 설치방법 (Installation Methods of Micro-piles by the Length Ratio of Pile and the Depth of Rock Layer)

  • 황태현;권오엽
    • 한국지반공학회논문집
    • /
    • 제27권4호
    • /
    • pp.5-20
    • /
    • 2011
  • 본 연구는 토사지반 또는 유한심도 내 암반층이 있는 지반을 대상으로 마이크로파일의 효과적인 설치방법을 제안하고 제안된 설치방법의 적용성을 평가하기 위해 수치해석을 수행하였다. 해석결과, 지반에 설치된 파일이 강체거동을 하는 경우는 파일 선단부와 암반층 위치 따라 파일 보강지반 지지력이 달라지나, 연성거동을 하는 경우는 파일 선단부와 암반층의 위치보다 파일강성과 관련한 파일 설치길이와 파일 근입길이에 따라 지지력이 달라지는 것으로 나타났다.

Experimental study on axial response of different pile materials in organic soil

  • Canakci, Hanifi;Hamed, Majid
    • Geomechanics and Engineering
    • /
    • 제12권6호
    • /
    • pp.899-917
    • /
    • 2017
  • Sixty four tests were performed in a steel tank to investigate the axial responses of piles driven into organic soil prepared at two different densities using a drop hammer. Four different pile materials were used: wood, steel, smooth concrete, and rough concrete, with different length to diameter ratios. The results of the load tests showed that the shaft load capacity of rough concrete piles continuously increased with pile settlement. In contrast, the others pile types reached the ultimate shaft resistance at a settlement equal to about 10% of the pile diameter. The ratios of base to shaft capacities of the piles were found to vary with the length to diameter ratio, surface roughness, and the density of the organic soil. The ultimate unit shaft resistance of the rough concrete pile was always greater than that of other piles irrespective of soil condition and pile length. However, the ultimate base resistance of all piles was approximately close to each other.