• Title/Summary/Keyword: Length of Sample

Search Result 943, Processing Time 0.023 seconds

Comparative seed morphology of Solanaceae in Korea (한국산 가지과의 종자 비교형태)

  • Kong, Min-Jung;Lee, Jong-Su;Hong, Suk-Pyo
    • Korean Journal of Plant Taxonomy
    • /
    • v.41 no.1
    • /
    • pp.35-46
    • /
    • 2011
  • The seed morphology of 22 taxa (12 genera) of Solanaceae in Korea was studied by stereo and scanning electron microscopy, and a detailed description of seed morphological features for all examined taxa is provided. The color of the seed is yellow to black, and the shape is reniform to circular. Its size is 0.56-4.29 mm in length and 0.38-3.20 mm in width. The largest sample was found in Datural metel, while the smallest was in Petunia hybrida. Three different surface types (verrucate, verrucate-reticulate, and reticulate) were recognized in the studied taxa. The top of the anticlinal wall produces appendages known as 'fibrils'. This projection of anticlinal wall was found to be specific to the genus Solanum (S. japonense, S. lyratum, and S. lycopersicum). The morphological features (seed shape, size, color, hilum shape, surface type, and fibrils) of the family Solanaceae in Korea are described and their systematic implications are briefly discussed.

Relationship between Dimensionless Leg Stiffness and Kinetic Variables during Gait Performance, and its Modulation with Body Weight

  • Hyun, Seung Hyun;Ryew, Che Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.249-255
    • /
    • 2016
  • Objective: This purpose of this study was to analyze the relationship between dimensionless leg stiffness and kinetic variables during gait performance, and its modulation with body weight. Method: The study sample consisted of 10 young women divided into 2 groups (Control, n=5 and Obese, n=5). Four camcorders (HDR-HC7/HDV 1080i, Sony Corp, Japan) and one force plate (AMTI., USA) were used to analyze the vertical ground reaction force (GRF) variables, center of pressure (COP), low limb joint angle, position of pelvis center and leg lengths during the stance phase of the gait cycle. Results: Our results revealed that the center of mass (COM) displacement velocity along the y-axis was significantly higher in the obese group than that in control subjects. Displacement in the position of the center of the pelvis center (Z-axis) was also significantly higher in the obese group than that in control subjects. In addition, the peak vertical force (PVF) and dimensionless leg stiffness were also significantly higher in the obese group. However, when normalized to the body weight, the PVF did not show a significant between-group difference. When normalized to the leg length, the PVF and stiffness were both lower in the obese group than in control subjects. Conclusion: In the context of performance, we concluded that increased dimensionless leg stiffness during the gait cycle is associated with increased velocity of COM, PVF, and the change in leg lengths (%).

Variation of target strength by swimming orientation and size for Pacific herring (Clupea pallasii) at the frequency of 70-kHz (주파수 70 kHz를 이용한 청어의 유영자세각과 체장에 따른 초음파산란강도의 변동)

  • PARK, Miseon;YOON, Euna;HWANG, Kangseok;LEE, Donggil;OH, Wooseok;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.4
    • /
    • pp.396-403
    • /
    • 2017
  • We measured the target strength according to the swimming tilt angle and size change for Pacific herring at the frequency of 70 kHz as the basic database in order to estimate its abundance as well as density in the survey area using the hydroacoustical method. The number of the sample used in this study was 14 individuals, and its size distribution by fork length ranged between 20.3 and 29.8 cm and wet weight was measured between 187.6 and 269.9 g. The variation of TS according to the swimming angle ($-30{\sim}30^{\circ}$) was measured between 10.3 and 18.8 dB in frequency range, the highest value was measured at head-down of Pacific herring in the tilt angle range between 5 and 9 deg. of its swimbladder. The relationship between TS-FL of herring was the same as $TS=20log_{10}$ (FL) - 66.79 when its swimming tilt angle in the daytime ($3.8{\pm}6.0^{\circ}$) and nighttime ($-3.2{\pm}13.6^{\circ}$), respectively.

Study of Color Evolution by Silica Coating and Etching based Morphological Control of α-FeOOH (실리카 코팅과 에칭에 의한 α-FeOOH의 색상변화 연구)

  • Lee, NaRi;Yu, Ri;Kim, YooJin
    • Journal of Powder Materials
    • /
    • v.25 no.5
    • /
    • pp.379-383
    • /
    • 2018
  • Silica is used in shell materials to minimize oxidation and aggregation of nanoparticles. Particularly, porous silica has gained attention because of its performance in adsorption, catalysis, and medical applications. In this study, to investigate the effect of the density of the silica coating layer on the color of the pigment, we arbitrarily change the structure of a silica layer using an etchant. We use NaOH or $NH_4OH$ to etch the silica coating layer. First, we synthesize ${\alpha}-FeOOH$ for a length of 400 nm and coat it with TEOS to fabricate particles with a 50 nm coating layer. The coating thickness is then adjusted to 30-40 nm by etching the silica layer for 5 h. Four different shapes of ${\alpha}-FeOOH$ with different colors are measured using UV-vis light. From the color changes of the four different shapes of ${\alpha}-FeOOH$ features during coating or etching, the $L^*$ value is observed to increase and brighten the overall color, and the $b^*$ value increases to impart a clear yellow color to the pigment. The brightest yellow color was that coated with silica; if the sample is etched with NaOH or $NH_4OH$, the $b^*$ value can be controlled to study the yellow colors.

Effects of Aquatic Intervention on Range of Motion, Gross Motor Function and Balance in the Children with Cerebral Palsy : Meta-Analysis (뇌성마비 아동의 수중 중재가 관절가동범위와 대동작기능 및 균형에 미치는 효과 : 메타분석)

  • Choi, Kibok;Cho, Sunghyoun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.71-83
    • /
    • 2019
  • Purpose: This meta-analysis aimed to analyze to the effects of aquatic exercise programs in children with cerebral palsy and identify directions for future research. Methods: A systematic search based on the PRISMA guidelines was undertaken for studies conducted between 2006 and 2018 on aquatic exercise programs in children with cerebral palsy. A total of 10 studies were selected according to the inclusion criteria. The methodological quality was assessed using the Risk of Bias Tool for Randomized Controlled Trials (RoB) and Risk-of-Bias Assessment Tool for Non-randomized Studies (RoBANS). A meta-analysis software (CMA 3.0) was used to calculate the mean effect size, effect size by intervention (Halliwick and Watsu Aquatic methods), and effect size by outcome. Results: The mean effect size was 0.457. The effect size by intervention was largest for the Halliwick method, followed by the Watsu method. The effect size by outcome was largest for range of motion, followed by the gross motor function measure, the Pediatric Berg Balance Scale, and the Modified Ashworth Scale. Meta-regression analysis showed effect size increased when sample size, number of sessions, and length of sessions increased. Conclusion: The results show that aquatic exercise programs have a positive effect on children with cerebral palsy. Therefore, it is necessary to develop a guideline that recommends the appropriate intervention and the identifies the direction of future studies on aquatic exercise programs.

Statistical Analysis of Quantitative Traits of Saccharina japonica cultured in Goheung, Jellanam-do (전남 고흥 양식 다시마의 양적형질에 대한 통계적 분석)

  • Yun, Y.S.;Kim, C.W.;Choi, S.J.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.22 no.2
    • /
    • pp.59-67
    • /
    • 2020
  • Growth tests on the Wando and Baengnyeongdo cultivars of Saccharina japonica were performed at the Myeongcheon and Gyedo aquafarms, Goheung in Jeollanamdo, from February to July in 2003. Five environmental conditions and 2 traits were measured monthly. The data were used to analyze the growth patterns, relationships between traits and principal component. Box plots were used to display the growth patterns. Scatter plots and regression and correlation coefficients were used to determine the strength of relationships between the traits. A principal component analysis revealed that the first principal component explained more than 91.4% and 90.5% of the total sample variance in the Myeongcheon and Gyedo aquafarms. From the viewpoint of the economic traits (blade length, blade weight), the growth of populations from the Gyedo aquafarm was stronger than that of those from the Myeongcheon aquafarm, and the growth of the Baengnyeongdo cultivar was superior to that of the Wando one.

Correlation Analysis of Pelvic Tilt and Gait according to the Paralytic Side of Stroke Patients (뇌졸중 환자의 마비쪽에 따른 골반의 기울임과 보행의 상관관계 분석)

  • Yong Seon, Lee;Jong-Hyuk, Yun
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.4
    • /
    • pp.111-120
    • /
    • 2022
  • Objective: This study investigated the effect of pelvic tiltng according to the paralytic side on gait in stroke patients during a 10 m functional movement timed up and go (TUG) test. Method: In this study, gait parameters were measured using a gait analyzer for 20 stroke patients and their gait was analyzed during a 10 m TUG test. For statistical analysis, an independent sample t-test were performed for age, height, and weight among general characteristics of subjects and homogeneity was tested by performing a chi-square test for gender, paralysis side, period of onset, and K-MMSE score. In order to understand the relationship between each variable, Pearson correlation analysis was performed on the variables. Results: First, the right-hand paralyzed group showed correlations in cadence and gait velocity in the up and down tilt of the pelvis, and the left-hand paralyzed group showed correlations in cadence and step length in the anterior and posterior tilt of the pelvis. Second, the tilt of the pelvis was correlated with the Sit to stand, walk forward, walk backwards, turn around at the end point, sit on a chair and the total TUG time in the right hemiplegic group compared to the left hemiplegic group. Conclusion: In this study, a significant correlation was confirmed as a result of gait analysis of right-handed stroke patients divided into a right paraplegic group and a left paraplegic group. In the future, it is suggested that treatment for improving gait of stroke patients should be treated differently for the right and left paralyzed side.

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • Analytical Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

Computer Vision-Based Measurement Method for Wire Harness Defect Classification

  • Yun Jung Hong;Geon Lee;Jiyoung Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2024
  • In this paper, we propose a method for accurately and rapidly detecting defects in wire harnesses by utilizing computer vision to calculate six crucial measurement values: the length of crimped terminals, the dimensions (width) of terminal ends, and the width of crimped sections (wire and core portions). We employ Harris corner detection to locate object positions from two types of data. Additionally, we generate reference points for extracting measurement values by utilizing features specific to each measurement area and exploiting the contrast in shading between the background and objects, thus reflecting the slope of each sample. Subsequently, we introduce a method using the Euclidean distance and correction coefficients to predict values, allowing for the prediction of measurements regardless of changes in the wire's position. We achieve high accuracy for each measurement type, 99.1%, 98.7%, 92.6%, 92.5%, 99.9%, and 99.7%, achieving outstanding overall average accuracy of 97% across all measurements. This inspection method not only addresses the limitations of conventional visual inspections but also yields excellent results with a small amount of data. Moreover, relying solely on image processing, it is expected to be more cost-effective and applicable with less data compared to deep learning methods.

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.