• Title/Summary/Keyword: Length of Sample

Search Result 941, Processing Time 0.026 seconds

A Selectively Cumulative Sum (S-CUSUM) Control Chart with Variable Sampling Intervals (VSI) (가변 샘플링 간격(VSI)을 갖는 선택적 누적합 (S-CUSUM) 관리도)

  • Im, Tae-Jin
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.11a
    • /
    • pp.560-570
    • /
    • 2006
  • This paper proposes a selectively cumulative sum (S-CUSUM) control chart with variable sampling intervals (VSI) for detecting shifts in the process mean. The basic idea of the VSI S-CUSUM chart is to adjust sampling intervals and to accumulate previous samples selectively in order to increase the sensitivity. The VSI S-CUSUM chart employs a threshold limit to determine whether to increase sampling rate as well as to accumulate previous samples or not. If a standardized control statistic falls outside the threshold limit, the next sample is taken with higher sampling rate and is accumulated to calculate the next control statistic. If the control statistic falls within the threshold limit, the next sample is taken with lower sampling rate and only the sample is used to get the control statistic. The VSI S-CUSUM chart produces an 'out-of-control' signal either when any control statistic falls outside the control limit or when L-consecutive control statistics fall outside the threshold limit. The number L is a decision variable and is called a 'control length'. A Markov chain model is employed to describe the VSI S-CUSUM sampling process. Some useful formulae related to the steady state average time-to signal (ATS) for an in-control state and out-of-control state are derived in closed forms. A statistical design procedure for the VSI S-CUSUM chart is proposed. Comparative studies show that the proposed VSI S-CUSUM chart is uniformly superior to the VSI CUSUM chart or to the Exponentially Weighted Moving Average (EWMA) chart with respect to the ATS performance.

  • PDF

Length-weight Relationship and Condition Factor of Zacco platypus in the Lake Hoengseong (횡성호에 분포하는 피라미 (Pale chub: Zacco platypus) 개체군의 Length-weight Relationship 및 Condition Factor)

  • Jang, Young-Su;Choi, Jae-Seok;Lee, Kwang-Yeol;Seo, Jin-Won;Kim, Bom-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.3
    • /
    • pp.412-418
    • /
    • 2007
  • The dynamics of Zacco platypus population of upstream and downstream in the lake Hoengseong, Korea were investigated from April to October 2005. Length-weight relationship, condition factor (K) and relative condition factor $(K_n)$ of Z. platypus were compared by the study stations. The equations based on length-weight relationship in the lake Hoengseong were $Log(T_w)=-2.2s+3.18{\cdot}Log(T_L)\;(r^2=0.99)$. The result in comparison of variations of Z. platypus populations, in lake was more remain to better than in upstream and downstream them. Also the b value, assessed by Length-weight relationship in lake was 3.36, in upstream and downstream were 3.09, 3.15, respectively indicating the fish in lake better than stream. The slopes of population condition controlled by K factor also showed positive relationship. It was higher in lake environment than in stream sample, reflecting that population of Z. platypus distributed in lake Hoengseong was favorable and stable condition. The lake environment seems to be providing more favorable condition for Z. platypus population.

A Study on the Classification of an Bodice Size of Rent Wedding Dress (대여 웨딩드레스의 상반신 사이즈 분류에 관한 연구)

  • Park Hee-Young;Lee Hyo-Jin
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.5 s.104
    • /
    • pp.13-28
    • /
    • 2006
  • The object of this study lies on classifying the size, which is mostly favored in Korea where the wedding dress is usually regarded as an article for rent, and on suggesting the range of sleeve design and that of neck line of bodice. For that, I extracted the average size by analyzing and researching the standard size of actual bodice from real wedding dress manufacturing company. According to the result of the research I named the standard size of Korean wedding dress for rent as 'WM' which has the girth of 88cm and the waist measure of 69cm. Based on the size 'WM', I also named the size 'WS' which has the girth of 82cm with extra length of 6cm up and down and the waist measure of 64cm with extra length of 5cm, and the size 'WL' which has the girth of 94cm and the waist measure of 74cm with same extra length as the size 'WS'. The extra space for the inseam of the back is 3 inches for left and right for all sizes and the mark of body size is standardized as 'girth-waist measure'. After that, I suggested the design types of sleeves and neck line of bodice which defined as its size by classifying the bodice of wedding dress based on its size. Generally the neck line of the tank top style has the widest range of wearable size, and the high neck line and bateau neck line types have the narrowest range. And the sleeveless type has the widest range of wearable size while the raglan type has the narrowest one.

Influence of operator's experience level on lifespan of the WaveOne Primary file in extracted teeth

  • Saleh, Abdulrahman Mohammed;Tavanafar, Saeid;Vakili-Gilani, Pouyan;Al Sammerraie, Noor Jamal;Rashid, Faahim
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.4
    • /
    • pp.222-226
    • /
    • 2013
  • Objectives: The aim of this study was to assess the influence of operator experience level on the lifespan of the WaveOne Primary file (Dentsply Maillefer, Ballaigues, Switzerland) in extracted teeth. Materials and Methods: Moderately curved canals of extracted maxillary and mandibular molars were randomly distributed into 2 groups: experienced and inexperienced operators. Ten files were allocated to each group (n = 10). Each canal was prepared until the working length was reached, and the same file was used to prepare additional canals until it separated. The number of canals prepared before file separation was recorded. The fragment length of each file was measured, and the location of the fragment in the canal was determined. Data were statistically analysed using the independent 2-sample t-test. Results: The 2 operators prepared a total of 324 moderately curved canals of maxillary and mandibular molars. There was no significant intergroup difference in the mean number of canals prepared (p = 0.27). The average lifespan of the WaveOne Primary file was 17.1 and 15.3 canals, and the longest lifespan was 25 and 20 canals, when used by experienced and inexperienced operators, respectively. There were no statistically significant intergroup differences in separated fragment length and location. Conclusions: Within the limitations of this study, operator experience level appears to have no effect on the lifespan of the WaveOne Primary file in preparation of moderately curved canals. Single teeth with multiple canals can be prepared safely even by a novice operator by using a single file.

A Study of the Inverter Optimization Design for EEFL BLU (EEFL BLU 구동용 인버터 최적화 설계에 대한 연구)

  • Kim, S.B.;Lee, S.H.;Kang, J.G.;Cho, M.R.;Shin, S.W.;Lee, S.H.;Hwang, M.K.;Yang, S.Y.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.241-245
    • /
    • 2006
  • EEFL(External Electrode Fluorescent Lamp) for LCD displays are analyzed on electrical and optical characteristics by various electrode length. The electrodes of EEFL are coated at the outside of the glass tube. Brightness and efficiency of the EEFL are affected on lamp impedance characteristic. So, the experimental models are proposed for analysis and measurements of the brightness and efficiency of the lamps according to the electrode length. The sample of LCD backlight unit is used for these experiments, EEFL arrayed BLU of 32' for commercial TV display. The parameters of the experiments were quantised for simple result reading as the length of electrodes as 15, 23 and 30 mm. The inverter was designed and manufactured in the laboratory as the Full-Bridge switching inverter. The feature of the output were measured on voltages about 1000 - 1400V at the currents of 11 - 29 mA and the brightness $15,000\;cd/m^2-40,000\;cd/m^2$. The experiments have shown that the brightness are increased by increasing of the electrode lengths which have the lamp currents increased. But at an certain conditions, the brightness and efficiency were decreased because of unmatched between the inverter output and lamp impedance. The optimum applications of the EEFL BLU of 32' in this experiments have been shown to choose the parameters for driving frequencies of 100 kHz - 150 kHz, the brightness of $18,000-19,000\;cd/m^2$ and efficiencies of 40 - 45 lm/w.

  • PDF

Length of hospital stay among oral and maxillofacial patients: a retrospective study

  • Tan, Fo Yew;Selvaraju, Kalpana;Audimulam, Harshinie;Yong, Zhi Chuan;Adnan, Tassha Hilda;Balasundram, Sathesh
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.1
    • /
    • pp.25-33
    • /
    • 2021
  • Objectives: Many conditions of the oral and maxillofacial region require hospitalization and in-patient care. The average length of stay (LOS) of these patients varies and is usually affected by multiple confounding variables. However, even with an increasing number of hospital admissions, published evidence on the factors that affect the LOS of oral and maxillofacial patients is lacking. Therefore, this study assessed the LOS of in-patients at the oral and maxillofacial surgery department of a government-funded, multi-specialty hospital in Malaysia, based on their reasons for admission and other factors. Materials and Methods: Our samples were collected retrospectively over a 5-year period and included patients with maxillofacial infections, post-trauma stabilization, facial bone fracture surgery, benign and malignant lesion surgery, dentoalveolar surgery, and other maxillofacial surgeries as reasons for admission. Factors potentially affecting LOS were also recorded, and their significance was determined using multiple logistic regression analyses. A P-value of less than 0.05 was considered to be statistically significant. Results: A total of 1,380 patients were included in this study. Most (84.5%) of our in-patients were of Malay ethnicity, and males outnumbered females in our sample by 502 subjects. The median LOS of our in-patients was 3 days. Sex, ethnicity, age, reason for admission, and American Society of Anesthesiology (ASA) classification were factors that significantly affected LOS. Conclusion: The median LOS reported in this study was 3 days. LOS was significantly affected by sex, ethnicity, age, reason of admission and ASA classification.

Adaptation of Phragmites communis Trin. Population to Soil Salt Contents of Habitas (생육지의 토양염분농도에 대한 갈대 ( Phragmites communis Trin. ) 개체군의 적응)

  • Lee, Ho-Joon
    • The Korean Journal of Ecology
    • /
    • v.16 no.1
    • /
    • pp.63-74
    • /
    • 1993
  • The ecotypic variation of Phragmites communis Trin. was studied from Aug. 1989 to March 1992 in three populations of salt marsh, estuary and fresh water areas of the western coastal regions in Korea. The length growth and aboveground total dry weight of Phragmites communis Trin. From three habitates were measured monthly and the seeds from them collected. Chlorophyll contents, bud number and width of Phragmites communis Trin. populations after their seeds were sown in seedbeds, and the growth of seedlings according to salt contents were also determined. The results lare summarized as follows: The height and basal diameter of shoot, leaf length and width, and total dry weight of Phragmites communis Trin. were very different from each other according to their natural habitats. The bud number of seeds was increased as sample sites moved from estuary to fresh water areas and salt marsh. The but the bud diameter turned out to be in reverse proportion to the bud number. The chlorophyll content of the population from fresh water was $8.6901{\mu}g/ml$, whereas that from estuary and salt marsh was $9.61801{\mu}g/ml$ and $10.3160{\mu}g/ml$, respectively. The average length growth and total dry weight of seedlings grown at different salt contents were compared. Those of fresh water area decreased at salt contents lower than 0.5% in culture solution and those of estuary at higher than 0.5%, but the population of salt marsh was shown to be capable of sustaining itself at 1.0%. All of these results suggested that the populations of Phragmites communis Trin. in the western coastal regions of Korea have undergone ecotypic variations: fresh water type, estuary type and salt marsh type.

  • PDF

Mechanism of failure in the Semi-Circular Bend (SCB) specimen of gypsum-concrete with an edge notch

  • Fu, Jinwei;Sarfarazi, Vahab;Haeri, Hadi;Marji, Mohammad Fatehi;Guo, Mengdi
    • Structural Engineering and Mechanics
    • /
    • v.81 no.1
    • /
    • pp.81-91
    • /
    • 2022
  • The effects of interaction between concrete-gypsum interface and edge crack on the failure behavior of the specimens in senicircular bend (SCB) test were studied in the laboratory and also simulated numerically using the discrete element method. Some quarter circular specimens of gypsum and concrete with 5 cm radii and hieghts were separately prepared. Then the semicircular testing specimens were made by attaching one gypsum and one concrete sample to one another using a special glue and one edge crack is produced (in the interface) by do not using the glue in that part of the interface. The tensile strengths of concrete and gypsum samples were separately measured as 2.2 MPa and 1.3 MPa, respectively. during all testing performances a constant loading rate of 0.005 mm/s were stablished. The proposed testing method showed that the mechanism of failure and fracture in the brittle materials were mostly governed by the dimensions and number of discontinuities. The fracture toughnesses of the SCB samples were related to the fracture patterns during the failure processes of these specimens. The tensile behaviour of edge notch was related to the number of induced tensile cracks which were increased by decreasing the joint length. The fracture toughness of samples was constant by increasing the joint length. The failure process and fracture pattern in the notched semi-circular bending specimens were similar for both methods used in this study (i.e., the laboratory tests and the simulation procedure using the particle flow code (PFC2D)).

A Roentgenographic Study on the Development of Roots of Mandibular Permanent Posterior Teeth (하악영구구치 치근발육에 관한 방사선학적 연구)

  • 고명연;정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.6 no.1
    • /
    • pp.23-34
    • /
    • 1981
  • In order to evaluate the correlation of age with development stage on permanent lower posterior teeth. the author exmined the roentgeregrams in standard films taken by intraoral technic and analysed the development phases of 1358 teeth of 500 males ranging from 9 to 15 years. The development was divided into 7 phases : Crown complete (Cr. C.). Root length 1/4(R. 1/4) Root length /2 (R. 1/2) Apical closure complete (A.C) The obtained results were as follows : 1. The formation of roots in full length on posterior teeth was complete as follow : a. Roots of 1st premolar : 12.72 years b. Roots of 2nd premolar : 12.94 years c. Meral Roots of 2nd molar : 13.38 years d. Distal Roots of 2nd molar : 13.46 years 2. The formation of apical forman of premolar was closured as follows : a. Apical foramen of root of 1st premolar : 13.64 years b. Apical foramen of root of 2nd premolar : 13.93 years 3. As a general rule. the mesial roots of second molar were developed earlier than distal roots of second molar. 4. In the correlation of age with the development stage, the regression equations. the correlation coefficents. and the sample numbers were “Y = 0.8370x + 10.2160, r = 0.71(p<0.01), n = 318”on lower first premolar, “Y = 0.6984x + 10.2148, r = 0.71(p<0.01), n = 385”on lower second premolar, “Y = 0.8810x + 10.2040, r = 0.65(p<0.01), n = 344”on mesial Root of lower second molar, and “Y = 0.7310x + 10.7940, r = 0.66(p<0.01), n = 311”on Distal Root of lower second molar respectively.

  • PDF

The Characteristics of Piezoelectric Transformer for Driving CCFL (CCFL 구동용 압전 변압기의 특성)

  • Jeong, Su-Hyun;Lee, Jong-Sub;Hong, Jong-Kuk;Chae, Hong-In;Yoon, Man-Soon;Lim, Kee-Joe
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.5
    • /
    • pp.259-264
    • /
    • 2000
  • In this paper, the characteristics of piezoelectric transformer is studied for driving CCFL(Cold Cathode Fluorescent Lamp). In order to investigate the effects of geometrical dimensions, λvibration-mode type piezoelectric transformers with different sizes in the length(l), width$(\omega)$ and thickness(t) are made of ceramics with PZT-PMWS compositions. The increases in temperature and aging effect are also measured in the transformer of PT-3 sample under the condition of operation continuously for 10 hrs. As the results of dimensional effects, the output power and voltage step-up ratio are largely affected by the ratio of length to thickness(l/t) rather than that of length to $width(l/\omega)$. The output power and step-up ratio are increased with increasing l/t. On case of PT-3, the output voltages are 510[Vrms] at 36[Vrms] in input voltage, $100[k\Omega]$ in load resistance. Temperature increases and variation of output voltages are $10[^{\circ}C]$ and less than 5[%], respectively.

  • PDF