• 제목/요약/키워드: Length of Sample

검색결과 937건 처리시간 0.029초

코어 변화에 대한 자계 특성 (Magnetic Field Properties About Core Change)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제25권2호
    • /
    • pp.159-164
    • /
    • 2012
  • In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.

Determining the Decision Limit of CUSUM Chart for A Fixed Sample Size

  • Kang, Chang Wook;Hawkins, Donglas M.
    • 품질경영학회지
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 1992
  • When we compare different control charting schemes, the average run length of each control chart is usually used. The use of the average run length implies that there is unbounded number of samples or observations. The regression recursive residuals, however, have been applied to the cumulative sum chart to detect whether the mean or variance changes. To implement choice of decision interval, we calculate the probability that certain fixed number of control statistics stay in the in-control state. This probability can be used as the significance level of a test for detecting the change in the residual mean or variance of the data with a finite number of observations.

  • PDF

효율적인 Micromixer의 통합된 기능 평가 및 Glucose-Catalysts 반응에 적용 (Integrated function evaluation of efficient micromixer and application to glucose-catalysts reaction)

  • 김덕중;백주열;이상훈
    • 센서학회지
    • /
    • 제14권5호
    • /
    • pp.291-296
    • /
    • 2005
  • In this paper, the PDMS based micromixer having 3-dimension triangular structure has been developed for the reaction of samples in the micro volume. The mixing efficiency was measured according to the change of Reynolds number (Re: 0.08, 0.8, 8, 16) and channel height (100, 200, $300{\mu}m$). Total length of mixing region is 7.4 mm and the measured mixing efficiencies at the outlet were over 85 %. Within the mixing length 2.4 mm, the mixing efficiencies were more than 70 % at any Reynolds numbers, and this indicates the strong mixing has occurred inside the mixing channel due the triangular structures. By employing these 2 mixers, we have fabricated the microreactor to detect the glucose-catalysts reaction. The microreactor showed good reactivity of glucose and enzymes with the small amount of sample solution.

Comparison of the Kaplan-Meier and Nelson Estimators using Bootstrap Confidence Intervals

  • Cha, Young Joon;Lee, Jae Man
    • 품질경영학회지
    • /
    • 제23권4호
    • /
    • pp.42-51
    • /
    • 1995
  • The bootstrap confidence intervals are a computer-based method for assigning measures of accuracy to statistical estimators. In this paper we examine the small sample behavior of the Kaplan-Meier and Nelson-type estimators for the survival function using the bootstrap and asymptotic normal-theory confidence intervals. The Nelson-type estimator is nearly always better than the Kaplan-Meier estimator in the sense of achieved error rates. From the point of confidence length, the reverse is true. Also, we show that the bootstrap confidence intervals are better than the asymptotic normal-theory confidence intervals in terms of achieved error rates and confidence length.

  • PDF

허리굽힘 각도에 따른 요배근력특성에 관한 연구 (A study on back power for lumbar bending angle)

  • 김종인;양성환;박범
    • 산업경영시스템학회지
    • /
    • 제22권51호
    • /
    • pp.109-116
    • /
    • 1999
  • Most of carrying works have been performed in almost all production process, conveyer objects, machine equipment and work method. Then, they are made by unfitted design which doesn't consider physical condition of workers. So, it causes them to bring about forceful motion. This study investigated the back power for what difference between lumbar bending angle and back power by selecting 21 male aged 22∼30 years old. Lumbar angle were shared each 30, 60, 90 degrees and measured. The results of this study was that as lumbar angle was increasing, back power was decreased and were very significant differences for angles respectively. Besides. sample correlation coefficients were calculated in order to analyze the relationship between back power, anthropometric dimensions and grip strength. Back power was correlated with weight, arm length, hand length, breadth of palm, breadth of lower arm, breadth of wrist and left-right grip strength.

  • PDF

바이몰프 압전센서의 진동에너지 수확에 관한 연구 (A study of vibration energy harvesting for the bimorph piezoelectric sensor)

  • 김용혁
    • 센서학회지
    • /
    • 제19권4호
    • /
    • pp.313-319
    • /
    • 2010
  • Vibration energy harvesting is an attractive technique for potential powering of low power devices such as wireless sensors and portable electronic applications. Most energy generator developed to date are single vibration frequency based, and while some efforts have been made to broaden the frequency range of energy harvester. In this work, The effect of energy harvesting were investigated at various vibration frequencies, vibration beams, vibration point and test masses. The maximum output voltage of the bimorph piezoelectric cantilever was shifted according to vibration point. Vibration frequency with maximum output voltage decreased with the increasing length of vibration beam and increasing test mass. The sample with vibration beam length 0.5 L generated a peak output voltage of 32 $V_{rms}$ and shows a 45 % increase in voltage output in comparison to the corresponding original bimorph. It was found that a piezoelectric bimorph has a possibility to be as the energy harvesting cantilever, which is successfully tuned over a vibration frequency range to enable a maximum harvesting energy.

중환자실 간호사의 중환자실 증후군에 대한 지식과 간호수행도 (Intensive Care Unit Nurse's Knowledge and Nursing Performance on Intensive Care Unit Syndrome)

  • 양야기
    • 간호행정학회지
    • /
    • 제16권3호
    • /
    • pp.240-249
    • /
    • 2010
  • Purpose: This study was to investigate intensive care unit (ICU) nurse's knowledge and nursing performance on the intensive care unit syndrome. Method: A survey questionnaire was administered to a convenience sample of 123 nurses in a university hospital. Data were collected from August 1st to August 25th, 2009. Data were analyzed using SPSS/WIN 12.0. Results: The mean score for knowledge and nursing performance were66.96 and 74.97 respectively. According to the general characteristics, there were significant differences in knowledge depending on marital status, education level and career length and in nursing performance depending on their age, education level and career length. The correlation between knowledge and nursing performance was a significant positive one. Conclusion: Comprehensive educational programs are needed to decrease accident rates related to ICU syndrome and to improve the health of ICU patients.

Evaluation of the true-strength characteristics for isotropic materials using ring tensile test

  • Frolov, A.S.;Fedotov, I.V.;Gurovich, B.A.
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2323-2333
    • /
    • 2021
  • The paper proposes a technique for reconstructing the true hardening curve of isotropic materials from ring tensile tests. Neutron irradiated 42XNM alloy tensile properties were investigated. The calculation of the true hardening curve for tensile and compression tests of standard cylindrical samples was performed at the first step. After that, the FEM-model was developed and validated using the ring tension and compression tests (with the hardening curve defined in step 1). Finally, the true hardening curve was calculated by selecting the FEM-model parameters and its validation by ring sample tests in different states using an iterative method. For these samples, experimental and calculated gauge length values were obtained, and the corresponding material's constants were estimated.

터널브라킷 애자류 오염도 분석에 관한 연구 (A research on the Tunnel bracket insulator pollution characteristic in Korea Railroad)

  • 전용주;류영태;박영식;박기범;이태훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1963-1969
    • /
    • 2009
  • This paper introduces method to estimate pollutant negative influence to polymer type insulator according to the international standard. To accomplish this goal, effective sample collecting method was surface was collected directly with the same dimension. Distilled Through this method pollute is easily and accurately collected. The second step is pollutant analysis. Several analyze item is selected such as quantity, conductivity, contact angle, Optical Microscope(OM), IR spectrometer(FT-IR), Equivalent Salt Deposit Density(ESDD), Thermal Analyzer(TA) and ICP-AES. The third step, best represent tunnel was selected considering location, length and natural surroundings. Also to consider the difference at inside the tunnel, several bracket insulators were selected along to the location. To make the result precise, above procedure was repeated several times at the same target. Finally relation among type of train, numbers of movement, surroundings, length will be considered in combination with the pollution. With this result pollute map for KORAIL could be accomplished and inspect period will be optimized case by case.

  • PDF

의료기관별 뇌졸중 유형에 따른 진료비, 재원일수 이학요법료의 차이분석 (Analysis of Total Hospital Charges, Length of Stay, and Cost of Rehabilitation by Hospital and Stroke Type)

  • 김선미;김다양;이광수
    • 보건의료산업학회지
    • /
    • 제11권1호
    • /
    • pp.91-105
    • /
    • 2017
  • Objectives : This study analyzed the differences in length of stay(LoS), total hospital charges(THC), and cost of rehabilitation(CoR) between two types of stroke patients, intracerebral hemorrhage(ICH) and cerebral infarction(CI). Factors associated with these differences were also assessed. Methods : Data were obtained from the 2011 National Inpatient Sample data of Health Insurance Review and Assessment Service. We used propensity score matching to match the characteristics of the two types of stroke patients, and conducted a regression analysis to analyze their associations. Results : The differences between THC, LoS, and CoR by stroke and hospital types were shown. Each type of hospital showed different results. Conclusions : A rapidly aging population will accelerate the number of stroke patients requiring effective management. Studies evaluating healthcare utilization of stroke patients will provide evidence for both healthcare resources allocation and healthcare policy decisions.