• 제목/요약/키워드: Length Dimension

검색결과 665건 처리시간 0.026초

초고속기용 열박음 로터 제작을 위한 로터의 치수에 따른 가열온도의 해석적 예측 (Analytical Prediction of Heating Temperature to Manufacture Rotor with Shrink Fit for Ultra High Speed Motor According to Change Dimension of Rotor)

  • 홍도관;우병철;정연호;구대현;안찬우
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.963-968
    • /
    • 2009
  • This paper deals with shrink fit analysis of rotor by 2D cross-section, 2D axis-symmetry, and 3D FEM model. And this paper presents 2nd order approximation function of thermal expansion displacement by design variables (shape dimension, heating temperature, sleeve length, interference etc.), table of orthogonal array and RSM(response surface methodology). The possibility of the rotor with shrink fit is evaluated by thermal expansion displacement. If thermal expansion displacement is larger than interference, shrink fit enable to make the rotor. 2D axis-symmetry model and 3D model are more reasonable than 2D cross-section model, because stress and strain is different along length of shaft.

Numerical simulation and experimental investigation of the shear mechanical behaviors of non-persistent joint in new shear test condition

  • Wang, Dandan;Zhang, Guang;Sarfarazi, Vahab;Haeri, Hadi;Naderi, A.A.
    • Computers and Concrete
    • /
    • 제26권3호
    • /
    • pp.239-255
    • /
    • 2020
  • Experimental and discrete element method were used to investigate the effects of joint number and its angularities on the shear behaviour of joint's bridge area. A new shear test condition was used to model the gypsum cracks under shear loading. Gypsum samples with dimension of 120 mm×100 mm×50 mm were prepared. the length of joints was 2cm. in experimental tests, the joint number is 1, 2 and 3 and its angularities change from 0° to 90° with increment of 45°. Assuming a plane strain condition, special rectangular models are prepared with dimension of 120 mm×100 mm. similar to joints configuration in experimental test, 9 models with different joint number and joint angularities were prepared. This testing show that the failure process is mostly governed by the joint number and joint angularities. The shear strengths of the specimens are related to the fracture pattern and failure mechanism of the discontinuities. The shear behaviour of discontinuities is related to the number of induced tensile cracks which are increased by increasing the rock bridge length. The strength of samples decreases by increasing the joint number and joint angularities. Failure pattern and failure strength are similar in both of the experimental test and numerical simulation.

지역 및 안모형태에 따른 여고생의 치열궁 크기에 대한 비교 (A COMPARATIVE STUDY ON DENTAL ARCH DIMENSION OF HIGH SCHOOL FEMALES ACCORDING TO THE REGION OF RESIDENCE AND FACIAL TYPE)

  • 장재홍;김종철
    • 대한치과교정학회지
    • /
    • 제24권4호
    • /
    • pp.885-895
    • /
    • 1994
  • This study was performed to compare the dental arch dimensions of urban and rural high school females according to the region of residence and facial type. A model and cephalometric analysis was made from 48 urban and 48 rural high school females. The results of this study were obtained as follows : 1. Arch width in the urban group were similar to the rural group. 2. Lingual arch length at upper 1st premolar level in the urban group was larger than the rural group and lingual arch length at lower canine level in rural group was larger than the urban group. 3. Palatal height at canine level in the rural group was higher than the urban group. 4. Palatal heights at 2nd premolar and 1st molar level had correlation with the VERT index. In comparison of lingual arch dimensions according to Rickett's facial group, palatal heights at 2nd premolar and 1st molar level in dolichofacial group were lower than other groups.

  • PDF

장갑 설계 적용을 위한 손동작에 따른 손체표의 길이변화 분석 (Analysis of Changes in Hand Length Dimensions by Hand Motion for Glove Design)

  • 권오채;선미선;정기효;이민정;연수민;유희천;김희은
    • 대한인간공학회지
    • /
    • 제24권4호
    • /
    • pp.1-5
    • /
    • 2005
  • A glove design which reflects the changes in hand surface by hand motion can reduce the undesirable effects of use of gloves on hand performance. The present study examined changes in hand length dimensions due to hand motion and identified significant factors affecting the length changes. Recruiting 120 males and females in their 20s and 30s having various hand lengths, this study measured 10 hand length dimensions, defined at 2 hand areas(phalangeal and metacarpal areas) for 5 digits, when the hand is stretched and in fist, and then calculated the percentage of length increase for each dimension. ANOVA and simple-effect analyses showed the length change percentages were mainly different depending on digit and hand area: 111-127% at the phalangeal area and 112-116% at the metacarpal area. The length change percentages of the index, middle, ring, and little fingers in the phalangeal area ascended in order and showed a high correlation(r = 0.94)with the ranges of motion of the fingers.

A Study on Breast Type Classification & Discrimination Using Manual Measurement- Focusing on Korean Women in Their 20s -

  • Sohn, Boo-Hyun
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권5호
    • /
    • pp.137-146
    • /
    • 2020
  • 20대 미혼 여성 182명의 직접 계측치를 이용한 유방유형 분류에 유방전체 형상 요인, 유방상부내측형상 요인, 유방볼륨 요인, 유방하부외측형상 요인 등 4가지 요인이 추출되었다. 군집분석을 통해 '상부발달 유방', '밋밋한 유방', '하부 발달 유방', '돌출한 유방' 등 4유형의 유방유형으로 분류하였다. 유방유형은 목앞점~젖꼭지점길이, 목옆점~젖꼭지점길이, 유방안쪽점 사이간격, 젖꼭지 간격, 유방아래직경, 유방내측깊이, 유방바깥쪽길이, 유방아래길이, 젖가슴가쪽점~젖가슴위쪽점길이, 젖가슴 밑 윤곽선길이 등 10개 항목으로 판별 가능하다.

타이트-핏(Tight-Fit) 슬랙스 패턴구성을 위한 성인 남성의 하반신 채형에 관한 연구 (A Study on Lower Body Type of Adult Males for Tight-fit Slacks Pattern Making)

  • 도월희
    • 한국생활과학회지
    • /
    • 제12권4호
    • /
    • pp.559-570
    • /
    • 2003
  • The focus of this research was concerned with studying lower body type for Korean adult males. To understand the features of men's lower body required to organize an optimal sizing system for men's tight-fit slacks, information from the measuring values based on research on the physical standard of the nation(l997) were summarized; in addition, a factor analysis and a cluster analysis among multivariate analyses were performed. In terms of the need for appropriate fit in motorcycle wear, basic lower body parts applying to each item had to be taken into consideration to enhance sizing suitability. In the case of the length of the lower limbs, the inclusion of protectors plays an important role in affecting sizing. The factors related to the lower body were defined as follows: Factor 1 was the vertical dimension of the lower body, Factor 2 was the horizontal dimension of waist and hip, Factor 3 was the horizontal dimension of the lower limbs, Factor 4 was the length of hips, and Factor 5 was the ankle height. The lower body part was also divided into 3 clusters. Cluster 1 referred to the smallest stature and skeleton structure among the 3 body types. Cluster 2 represented the biggest stature, with a thin lower limbs body type. Cluster 3 represented a medium stature but with a large skeleton structure of lower limbs, a muscular type. In conclusion, Cluster 2 appeared most in the 20s age groups, but Cluster 3 appeared most in each of the 30s, 40's, and 50's age groups.

  • PDF

구동륜(驅動輪)의 성능예측(性能豫測)에 적합한 토양변수(土壤變數)의 차원해석(次元解析)을 위한 차륜(車輪)-토양(土壤) 시스템의 상사성(相似性) 연구(硏究)(I) -견인력(牽引力) 예측(豫測) 분석(分析)- (A Similitude Study of Soil-Wheel System for Identifying the Dimension of Pertinent Soil Parameter(I) -Pull Prediction Analysis-)

  • 이규승;정창주
    • Journal of Biosystems Engineering
    • /
    • 제14권2호
    • /
    • pp.67-79
    • /
    • 1989
  • This study was conducted to investigate the applicability of true model theory for pull prediction in a powered lugged wheel-soil system and to examine the possibility of using principles of similitude in investigating the dimensions of soil parameters pertinent to a powered lugged wheel-soil system concerning the pull prediction. The following conclusions were derived from the study; 1) The pull of prototype wheels proved to be predicted by those of the model wheels for the range of the dynamic weight tested. The pull curves of models and prototype were respectively very similar in the shape. From this basic knowledge, it was enabled to apply the similitude theory to the performance prediction of the true model. 2) A conditional equation which can be used for the prediction of pull of prototype by model test was derived as follows. $n_f=n_1^{-b}$ where $n_f$ : force scale = $w/w_m$ $n_1$ : length scale = ${\ell}/{\ell}_m$ b : exponent on the length dimension of the soil property ${\alpha}$ The range of the numerical value of b, which was determined by the least square method, was found to be -2.0~-2.6. 3) Considering a relatively wide variation of b values in the pull prediction, b is considered to be a function of many variales. Thus it was concluded that there are several soil properties which are pertinent to the powered lugged-wheel-soil system concerning the pull prediction, and these soil properties may have the different effects on the pull of model and protytype wheels, to give the different dimension on the soil parameters.

  • PDF

치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향 (Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin)

  • 임용운;황성식;김사학;이해형
    • 대한치과재료학회지
    • /
    • 제44권3호
    • /
    • pp.273-280
    • /
    • 2017
  • 본 연구의 목적은 치과용 복합레진의 굽힘특성과 시험 신뢰성에 대한 시편의 크기의 영향을 분석하기 위함이다. 실험용 치과용 복합레진은 레진 매트릭스와 50 vo%의 silane 처리된 글라스 필러를 혼합하여 제조하였다. 복합레진의 굽힘강도 시편은 폭의 크기가 다른 금속 몰드에 채워 각각 $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ (길이${\times}$높이${\times}$폭) 크기로 광중합하여 제작하였다 (n=10). 이들 굽힘 시편들은 ISO 4049 시험법에 의거 시편의 지지점간 거리 20 mm에서 굽힘강도와 굽힘탄성계수를 결정하였다 (normal-flexural strength; NFS). 여기서 파절된 시편들로부터 길이를 12 mm로 조정한 시편들($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$)을 이용하여 지지점간 거리 10 mm에서 다시 한번 굽힘특성값들 얻었다(mini-flexural strength; MFS). 데이터는 ANOVA와 Duncan 사후검정을 실시하였으며 결과의 신뢰도는 와이블 분석으로 실시하였다. 결과에서 NFS, MFS시험 모두 시편 폭의 증가에 따라 굽힘강도에는 유의한 차이가 나타나지 않았다(P > 0.05). 그러나 와이블 계수에 근거한 시험 신뢰도는 시편의 크기와 지지점간 거리의 변화에 따라 큰 변화가 발생하였다. NFS시험의 굽힘탄성계수는 시편의 크기 증가와 더불어 증가하였으나, MFS시험에 의한 탄성계수는 경향이 관찰되지 않았다. 본 연구의 결과를 종합하면, 치과용 복합레진의 굽힘특성과 그 신뢰도는 한가지 이상의 시험법으로 해야 함이 권장된다.

비폐쇄를 보이는 III급 부정교합아동의 기도 공간 형태와 안모 골격 형태와의 상관관계 연구 (A study on the correlation between airway space and facial morphology in Class III malocclusion children with nasal obstruction)

  • 정호림;정동화;차경석
    • 대한치과교정학회지
    • /
    • 제37권3호
    • /
    • pp.192-203
    • /
    • 2007
  • 본 연구는 비폐쇄를 보이는 III급 부정교합아동에서, 기도 공간의 형태와 안모 골격 형태 사이의 상관관계를 평가하였다. III급 부정교합을 보이며, 비폐쇄 소견을 보여 이비인후과로 의뢰된 환아 100명의 초진 측모 두부 규격 방사선 사진에서 상 인두기도 공간(upper PAS), 하 인두기도 공간(lower PAS), 편도의 크기, 구개-혀 공간을 측정하여 기도 공간 형태를 분석하였으며, 통상적인 계측점을 사용하여 안면 골격 분석을 시행하여 기도 공간 형태 계측항목과 안면 골격분성 항목간의 상관관계를 연구하여 다음과 같은 결과를 얻었다. Upper PAS는 ramal height, SNA, SNB, PFH, FHR, facial plane angle 항목과 양의 상관관계를 보였으며, saddle angle, articular angle, gonial angle의 sum, SN-GoGn, Y-axis to SN, FMA 항목과 음의 상관관계를 보였다. Lower PAS는 genial angle, FMA와 양의 상관관계를 보였으며, articular angle, facial depth, PFH, FHR와 음의 상관관계를 보였다. 편도의 크기는 PCBL, ramal height, Mn. body length, Mn. body length to ACBL, facial depth, facial length, PFH, AFH와 양의 상관관계를 보였다. 구개-혀 공간은 saddle angle, articular angle, genial angle의 합, facial length, AFH, FMA, LFH와 양의 상관관계를 보였으며, IMPA, overbite와 음의 상관관계를 보였다.

디지털방사선영상에서 추출한 해면질골의 강도와 미세구조의 형태계측학적 분석에 대한 연구 (A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image)

  • 한승윤;이선복;오성욱;허민석;이삼선;최순철;박태원;김종대
    • Imaging Science in Dentistry
    • /
    • 제33권2호
    • /
    • pp.113-119
    • /
    • 2003
  • Purpose : To evaluate the relationship between morphometric analysis of bone microstructure from digital radiographic image and trabecular bone strength. Materials and Methods : One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI (100 × 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1 mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Results: Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p < 0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p < 0.05). Conclusions : The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  • PDF