• 제목/요약/키워드: Leidenfrost point

검색결과 8건 처리시간 0.021초

Leidenfrost Points Tuned via Surface Coating and Structures

  • Jeon, Deok-Jin;Lee, Jun-Young;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.126.1-126.1
    • /
    • 2015
  • A quantitative relationship between Leidenfrost point and surface characteristics such as surface material and roughness is investigated. Based on the relationship, we have fabricated the surfaces with their Leidenfrost points (LFP) tuned by controlling surface coating and structures. As discovered by Leidenfrost, liquids placed on a hot plate levitate on the gas phase-air gap formed by the vaporization of liquids. This phenomenon is called 'Leidenfrost effect'. A change of LFP has attracted many researchers for several years but the ability to tune LFP is still a remaining issue. Many of previous work has progressed for various conditions so the systematic approach and analysis are needed to clearly correlate the LFP and the surface conditions. In this report, we investigate a relation of surface energy and LFP using various coating materials such as Octadecyltrichlorosilane (OTS) and 1H, 1H, 2H, 2H-Perfluorooctyltrichlorosilane (FOTS). Also, we analyze how surface roughness affects LFP via surface micro structuring with ICP-RIE fabrication process. The improved understanding can have potential applications such as the control of liquid droplet behavior at elevated temperatures for efficient cooling system.

  • PDF

막비등 영역에서 액적-벽면 충돌 시 충돌각도가 열전달에 미치는 영향에 관한 실험적 연구 (Experimental Study of Collision Angle Effects on Heat Transfer During Droplet-wall Collision in Film Boiling Regime)

  • 박준석;김형대
    • 한국분무공학회지
    • /
    • 제22권3호
    • /
    • pp.129-136
    • /
    • 2017
  • Effects of collision angle on heat transfer characteristics of a liquid droplet impinging on a heated wall above the Leidenfrost point temperature were experimentally investigated. The heated wall and droplet temperatures were $506^{\circ}C$ and $100^{\circ}C$, respectively, and the impact angle varied from $20^{\circ}$ to $90^{\circ}$ while the normal collision velocity was constant at 0.27 m/s. The droplet collision behaviors and the surface temperature distribution were measured using synchronized high-speed video and infrared cameras. The major physical parameters influencing upon droplet-wall collision heat transfer, such as residence time, wall heat flux, effective heat transfer area, heat transfer amount, were analyzed. It was found at the constant normal collision velocity that the residence time, wall heat flux and effective heat transfer area were hardly not changed, resulting in the almost constant heat transfer amount.

Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향 (The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature)

  • 박준석;김형대;배성원;김경두
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.567-578
    • /
    • 2015
  • Leidenfrost 온도 이상으로 가열된 벽면과 충돌하는 액적의 속도가 열전달 특성에 미치는 영향에 관한 실험 연구를 수행하였다. 동기화된 초고속 가시화 카메라와 적외선 카메라를 이용하여 벽면과 충돌하는 액적의 충돌 특성과 충돌면의 온도 분포를 측정하였다. 획득한 표면온도 분포를 충돌면의 경계 조건으로 이용하여 가열 벽면의 3차원 비정상 열전도 수치해석을 통해 표면 열유속 분포를 얻었다. 수직방향 충돌속도가 증가할수록 최대 액막 직경이 증가하고 가열 벽면과 액막 사이에 존재하는 증기막의 두께가 감소하여 열전달 효율이 증가하였다. 액적은 웨버수가 30보다 작은 경우 되튐현상이 발생하였으며, 큰 경우 작은 액적들로 분쇄되어졌다. 충돌속도에 의한 열전달량의 증가 경향이 되튐영역에서 분쇄영역에서 가면서 약화되었으며, 이는 분쇄현상에 의해 유효 열전달 면적의 확대 효과가 저감되었기 때문으로 해석된다.

Investigation on effect of surface properties on droplet impact cooling of cladding surfaces

  • Wang, Zefeng;Qu, Wenhai;Xiong, Jinbiao;Zhong, Mingjun;Yang, Yanhua
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.508-519
    • /
    • 2020
  • During transients or accidents, the reactor core is uncovered, and droplets entrained above the quench front collides with the uncovered fuel rod surface. Droplet impact cooling can reduce the peak cladding temperature. Besides zirconium-based cladding, versatile accidental tolerant fuel (ATF) claddings, including FeCrAl, have been proposed to increase the accident coping time. In order to investigate the effect of surface properties on droplet impact cooling of cladding surfaces, the droplet impact phenomena are photographed on the FeCrAl and zircaloy-4 (Zr-4) surfaces under different conditions. On the oxidized FeCrAl surface, the Leidenfrost phenomenon is not observed even when the surface temperature is as high as 550 ℃ with We > 30. Comparison of the impact behaviors observed on different materials shows that nucleate and transition boiling is more intensive on surfaces with larger thermal conductivity. The Leidenfrost point temperature (LPT) decreases with the solid thermal effusivity (${\sqrt{k{\rho}C_p}}$). However, the CHF temperature is relatively insensitive to the surface oxidation and Weber number. Droplet spreading diameter is analyzed quantitatively in the film boiling stage. Based on the energy balance a correlation is proposed for droplet maximum spreading factor. A mechanistic model is also developed for the LPT based on homogeneous nucleation theory.

고온벽면에서의 액적연료의 증발 및 착화에 관한 연구 (A Study on the Evaporation and Ignition of Single Fuel Droplet on the Hot Surface)

  • 송규근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.132-137
    • /
    • 2002
  • Recently, impinging spray is used for atomization of diesel engine, but it bring on adhesion of fuel. Therefore, we studied about droplet behavior on high temperature plate changing the size of droplet, surface temperatures, and surface roughness of plate. In this study, We studied to confirm experimentally about mechanism of evaporation and ignition process of single fuel droplet. We observed evaporation time, evaporation appearance and ignition delay time by the photopraphs of 8mm video camera. Experimental results are summarized as follows: 1. The boiling point of fuel affect a evaporation and ignition process. 2. The surface roughness affect a evaporation time. 3. The ignition delay time relate to evaporation characteristic.

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

Film Boiling Heat Transfer from Relatively Large Diameter Downward-facing Hemispheres

  • Kim Chan Soo;Suh Kune Y.;Park Goon Cherl;Lee Un Chul;Yoon Ho Jun
    • Nuclear Engineering and Technology
    • /
    • 제35권4호
    • /
    • pp.274-285
    • /
    • 2003
  • Film boiling heat transfer coefficients for a downward-facing hemispherical surface are measured from the quenching tests in DELTA (Downward-boiling Experimental Loop for Transient Analysis). Two test sections are made of copper to maintain Bi below 0.1. The outer diameters of the hemispheres are 120 mm and 294 mm, respectively. The thickness of both the test sections is 30 mm. The effect of diameter on film boiling heat transfer is quantified utilizing results obtained from the two test sections. The measured heat transfer coefficients for the test section with diameter 120 mm lie within the bounding values from the laminar film boiling analysis, while those for diameter 294 mm are found to be greater than the numerical results on account of the Helmholtz instability. There is little difference observed between the film boiling heat transfer coefficients measured from the two test sections. In addition, the higher thermal conductivity of copper results in the higher minimum heat flux in the tests. For the test section of diameter 120 mm, the Leidenfrost point is lower than that for the test section of diameter 294 mm. Destabilization of film boiling propagates radially inward for the 294 mm test section versus radially outward for the 120 mm Test Section.

주행하는 고온 강재의 상하부 동시 냉각 과정 수치해석 (Numerical Analysis of Simultaneous Cooling Process of Upper and Lower Side of Running Hot Steel Strip)

  • 권면재;박일석
    • 대한기계학회논문집B
    • /
    • 제38권12호
    • /
    • pp.1051-1056
    • /
    • 2014
  • 열간 압연을 거친 $800^{\circ}C$ 이상의 고온 철강 판재는 일반적으로 다중 봉상 수분류(multiple circular water jets)에 의해서 급속 냉각된다. 이 과정은 소재의 온도가 냉각수의 끓는점보다 훨씬 높기 때문에 소재 표면과 냉각수 사이에 막비등 열전달 현상이 발생하며 소재 표면에 매우 얇은 증기층이 형성되며, 이 증기층은 소재와 냉각수의 열교환을 방해하는 중요한 열저항으로 작용한다. 본 문제에는 비등 열전달 이외에도 소재 표면에 쌓이는 체류수의 자유표면 유동, 소재의 고속 주행 등 복잡한 물리현상들이 복합적으로 작용하고 있다. 본 논문에서는 이 모든 물리현상들을 동시에 고려할 수 있는 해석 절차를 적용하여 일정한 속도로 주행하는 고온 철강 판재의 상하부 동시 냉각 과정을 3 차원 수치해석 하였으며, 소재 상부 및 하부 면의 냉각 특성을 비교하였다.