• Title/Summary/Keyword: Leg reconstruction

Search Result 108, Processing Time 0.025 seconds

The superior lateral genicular artery flap for reconstruction of knee and proximal leg defects

  • Low, O-Wern;Loh, Tian Fu;Lee, Hanjing;Yap, Yan Lin;Lim, Jane;Lim, Thiam Chye;Nallathamby, Vigneswaran
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.108-114
    • /
    • 2022
  • Reconstruction of defects around the knee region requires thin and pliable skin. The superior lateral genicular artery (SLGA) flap provides an excellent alternative to muscle-based flaps. The anatomy and the surgical techniques of the SLGA flap were reviewed and the results of cases using the SLGA flap for coverage of knee and proximal leg defects were analyzed. SLGA flaps were performed in two cases and followed up for at least 6 months. Twelve articles on the use of the SLGA flap were also identified. A review of 39 cases showed that the mean diameter of the perforator supplying the skin of the flap was 1.04 mm, while the mean diameter of the SLGA at its origin was 1.78 mm. The mean length of the pedicle measured from the origin of the popliteal artery was 7.44 cm. The average dimensions of the flap were 14.8×6.6 cm with primary closure of the donor site in 61.5% of cases. Of these cases, 38.5% were due to trauma, 23.1% were post-burn complications, 12.8% were defects after resection of tumors, and 10.3% were for ulcers post-bursectomy. The most common complication was flap tip necrosis. All studies reported favorable outcomes with complete wound healing.

Mandible Reconstruction with 3D Virtual Planning

  • Woo, Taeyong;Kraeima, Joep;Kim, Yong Oock;Kim, Young Seok;Roh, Tai Suk;Lew, Dae Hyun;Yun, In Sik
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.90-93
    • /
    • 2015
  • The fibula free flap has now become the most reliable and frequently used option for mandible reconstruction. Recently, three dimensional images and printing technologies are applied to mandibular reconstruction. We introduce our recent experience of mandibular reconstruction using three dimensionally planned fibula free flap in a patient with gunshot injury. The defect was virtually reconstructed with three-dimensional image. Because bone fragments are dislocated from original position, relocation was necessary. Fragments are virtually relocated to original position using mirror image of unaffected right side of the mandible. A medical rapid prototyping (MRP) model and cutting guide was made with 3D printer. Titanium reconstruction plate was adapted to the MRP model manually. 7 cm-sized fibula bone flap was designed on left lower leg. After dissection, proximal and distal margin of fibula flap was osteotomized by using three dimensional cutting guide. Segmentation was also done as planned. The fibula bone flap was attached to the inner side of the prebent reconstruction plate and fixed with screws. Postoperative evaluation was done by comparison between preoperative planning and surgical outcome. Although dislocated condyle is still not in ideal position, we can see that reconstruction was done as planned.

The Effect of Silicone Sleeve and Taping on Balance and Strength in Anterior Cruciate Ligament Reconstruction Patients

  • Kwon, Hyo-Jeoung;Park, Dae-Sung;Jeong, Ju Ri;Jung, Kwang-Ik
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.3
    • /
    • pp.147-155
    • /
    • 2014
  • Purpose: This study was to determine the effects of before and after application of silicone sleeve on balance and muscle strength in anterior cruciate ligament (ACL) reconstruction patients. Methods: 13 subjects who had one or more months after ACL surgery were involved. Dynamic balance, timed up and go (TUG), stair step, vertical jump, proprioception and isokinetic knee strength were measured while subjects under taped, untapped and silicone sleeve conditions. Results: For 30 seconds one-leg standing, there was a significant improvement under silicone sleeve on operated side with eyes open and both taping and silicone sleeve revealed similar effects with eyes closed (p<0.01). Application of silicone sleeve showed significant effects in proprioceptive function on the operated side compared to both taping and none (p<0.05). For stair step test, TUG and vertical jump was a tendency to improve after application of silicone sleeve, but no significant different. Muscle strength on operated side of quadriceps and hamstring was significantly improved compared with none or taping(p<0.05). Conclusion: Silicone sleeve application for ACL reconstruction patients was effective immediately on improving strength and balance. Therefore, depending on the intended use and the disease is considered appropriate use of silicone sleeve will be able to help prevention and functional movement.

The Effects of Strengthening Exercise of Hip Abductors on Muscle Strength and Ambulation in Patient with ACL Reconstruction (앞십자인대 재건술 후 엉덩관절 벌림근 강화운동이 근력과 보행에 미치는 영향)

  • Park, Byung-Joon;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.296-301
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of strengthening exercises of hip abductors on muscle strength and ambulation for patients with ACL reconstruction. Methods: The subjects were randomly assigned to the intervention group (general exercise plus strengthening of hip abductors) or the control group (general exercise without the strengthening of hip abductors). Both groups participated in a six-week exercise protocol after the surgery for ACL reconstruction. The knee strength test (quadriceps, hamstring, hip abductor) and gait analysis were performed in pretest and post-test. Results: Muscle strength was measured using the Biodex system III model (Biodex Medical System, Inc, NY, US). The results showed no significant difference in knee strength (quadriceps, hamstring) between the two groups (p>0.05), however, there was a significant difference in hip abductors (p<0.05). The gait analysis was measured with Gaitrite system (CIR System Inc, US). Results of comparison between groups showed a significant increase in the step length of both groups. (p<0.05), and there was a significant difference in the affected leg of the intervention group(p<0.05). Conclusion: Exercise of hip abductors for patients with ACL reconstruction provides significant benefits with respect to improvement of muscle strength in hip abductors, increasing the stride. This result indicates that a training program designed for ACL reconstruction patients should include strengthening of the hip abductor. We think that further study is needed to determine the relationship of hip muscles and knee joint for patients with ACL reconstruction.

A Three-dimensional Biomechanical Model for Numerical Simulation of Dynamic Pressure Functional Performances of Graduated Compression Stocking (GCS)

  • Liu, Rong;Kwok, Yi-Lin;Li, Yi;Lao, Terence-T;Zhang, Xin;Dai, Xiao-Qun
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.389-397
    • /
    • 2006
  • The beneficial effects of graduated compression stockings (GCS) in prophylaxis and treatment of venous disorders of human lower extremity have been recognized. However, their pressure functional performances are variable and unstable in practical applications, and the exact mechanisms of action remain controversial. Direct surface pressure measurements and indirect material properties testing are not enough for fully understanding the interaction between stocking and leg. A three dimensional (3D) biomechanical mathematical model for numerically simulating the interaction between leg and GCS in dynamic wear was developed based on the actual geometry of the female leg obtained from 3D reconstruction of MR images and the real size and mechanical properties of the compression stocking prototype. The biomechanical solid leg model consists of bones and soft tissues, and an orthotropic shell model is built for the stocking hose. The dynamic putting-on process is simulated by defining the contact of finite relative sliding between the two objects. The surface pressure magnitude and distribution along the different height levels of the leg and stress profiles of stockings were simulated. As well, their dynamic alterations with time processing were quantitatively analyzed. Through validation, the simulated results showed a reasonable agreement with the experimental measurements, and the simulated pressure gradient distribution from the ankle to the thigh (100:67:30) accorded with the advised criterion by the European committee for standardization. The developed model can be used to predict and visualize the dynamic pressure and stress performances exerted by compression stocking in wear, and to optimize the material mechanical properties in stocking design, thus, helping us understand mechanisms of compression action and improving medical functions of GCS.

Reverse Superficial Sural Artery Flap for Reconstruction of Soft Tissue Defect (역혈행성 비복 동맥 피판술을 이용한 연부 조직 결손의 재건)

  • Lee, Sang-Soo;Lee, Young-Ho;Kim, Joo-Sung;Choi, Jae-Hyuck;Lee, Young-Hyun;You, Yeon-Sik;Nam, Il-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.46-53
    • /
    • 2002
  • Purpose: We would introduce the reverse superficial sural artery flap to reconstruct soft tissue defect on lower leg, ankle, and hind-foot. Materials and Method: From October 1998 to December 2001, we reconstructed 12cases (l2patients) of soft tissue defect around the hind - foot, ankle, and distal lower extremity with the reverse sural artery flap. Results: The time for flap dissection was 28 minutes in average. The size of the flap was from $4\times3cm$ to $14\times10cm$. All flaps survived. Conclusion: The reverse superficial sural artery flap is the useful technique for the soft tissue defect in the lower leg and the foot.

  • PDF

Consideration of the Carrier Based Signal Injection Method in Three Shunt Sensing Inverters for Sensorless Motor Control

  • Jung, Sungho;Ha, Jung-Ik
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1791-1801
    • /
    • 2016
  • This paper considers a carrier based signal injection method for use in the three shunt sensing inverter (TSSI) for sensorless motor control. It also analyzes the loss according to the injection axis of the voltage signal. To remove both the phase current and rotor position sensors, a sensorless method and a phase current reconstruction method can be simultaneously considered. However, an interaction between the two methods can be incurred when both methods inject voltage signals simultaneously. In this paper, a signal injection based sensorless method with the 120° OFF Discontinuous PWM (DPWM) is implemented in a TSSI to avoid this interaction problem. Since one leg does not have a switching event for one sampling period in the 120° OFF DPWM, the switching loss is altered according to the injection axis. The switching loss in the d-axis injection case can be up to 32% larger than that in the q-axis injection case. Other losses according to the injection axis are also analyzed.

Reconstruction of Tibial Defects in Lower Extremity With Various Versions of Vascularized Fibula Transfer (다양한 형태의 생 비골 이식술을 이용한 경골의 재건)

  • Nam, Sang-Hyun;Kim, Bom-Jin;Koh, Sung-Hoon;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.1
    • /
    • pp.17-25
    • /
    • 2006
  • Twelve cases in eleven patients with segmental bone defects were treated with contralateral fibula free flap and ipsilateral island fibula flap in an antegrade, retrograde or bidirectional flow fashion. Five cases were managed with free flaps and seven were with ipsilateral fibula island transfer. Among seven cases, antegrade fashion was three, retrograde was three, and bidirectional was one. All patients were related with open tibial fractures and its sequelae except one who had open foot bone fracture. According to Gustilo's classification, ten patients were type IIIb and one was type IIIc. Basically, antegrade-flow flaps based on the peroneal vessels as in the conventional free flap were used for the proximal or middle one-third tibial defects. On the contrary, retrograde-flow flaps based on the communicating branch between the peroneal and posterior tibial vessels were used for the middle or distal one-third of the tibia. Bidirection-flow flap based on intact peroneal vessels were used for the middle portion of the tibia. The patients who have undergone ipsilateral fibula island flap had one of the following problems: a previously failed free flap, below-knee amputation of the opposite leg because of open tibial fracture, refusal to use the contralateral sound leg, or poor general condition to stand a lengthy operation. Six of the patients who have got ipsilateral fibula island flap also had an associated fibula fracture on the same leg, which was ultimately used as one of the osteotomy sites. The follow-up period was from 1 to 10 years. Two cases of free flap were failed: one patient had below-knee amputation and the other patient had ipsilateral fibula transfer. Other cases were successful and excellent hypertophy of the transferred fibula was achieved. Time to bone union ranged from 4 to 11 months. Time to full weight bearing was from 5 to 13 months after surgery. All of the transferred fibulas showed hypertrophy after weight bearing. In one case, stress fracture was developed during ambulation, which was healed conservatively. Nonunion occurred in two cases, which were treated with a long leg cast and cancellous bone graft, respectively. Length discrepancy of the legs was noted. The limb was shorter by an average 0.5 cm in three cases, longer by 1.1 cm in one case. In the case of island fibula transfer, limited arc of rotation was not a problem. Other disabling complications were not seen. We believe that these diverse modalities using a vascularized fibula will make us more comfortable to handle major bone defects.

  • PDF

Functional Reconstruction of a Combined Tendocutaneous Defect of the Achilles Using a Segmental Rectus Femoris Myofascial Construct: A Viable Alternative

  • DeFazio, Michael Vincent;Han, Kevin Dong;Evans, Karen Kim
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.285-289
    • /
    • 2014
  • The composite anterolateral thigh flap with vascularized fascia lata has emerged as a workhorse at our institution for complex Achilles defects requiring both tendon and soft tissue reconstruction. Safe elevation of this flap, however, is occasionally challenged by absent or inadequate perforators supplying the anterolateral thigh. When discovered intraoperatively, alternative options derived from the same vascular network can be pursued. We present the case of a 74-year-old male who underwent composite Achilles defect reconstruction using a segmental rectus femoris myofascial free flap. Following graduated rehabilitation, postoperatively, the patient resumed full activity and was able to ambulate on his tip-toes. At 1-year follow-up, active total range of motion of the reconstructed ankle exceeded 85% of the unaffected side, and donor site morbidity was negligible. American Orthopaedic Foot and Ankle Society and Short Form-36 scores improved by 78.8% and 28.8%, respectively, compared to preoperative baseline assessments. Based on our findings, we advocate for use of the combined rectus femoris myofascial free flap as a rescue option for reconstructing composite Achilles tendon/posterior leg defects in the setting of inadequate anterolateral thigh perforators. To our knowledge, this is the first report to describe use of this flap for such an indication.

Perforator Based Tibialis Anterior Segmental Muscle Island Flap in Lower Extremity Reconstruction

  • Byun, Il Hwan;Kwon, Soon Sung;Chung, Seum;Baek, Woo Yeol
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.2
    • /
    • pp.69-71
    • /
    • 2016
  • Reconstruction of the lower extremities is difficult due to a lack of skin laxity and muscular tissues. Here, we present a case of lower extremity reconstruction via the anterior tibial artery perforator based segmental muscle island flap. Our patient was a 75-year-old male with a chronic ulcerative wound on the right lower leg from an old car accident. A $5.0{\times}0.5cm$ size ulcerative wound with tibial bone exposure was noted. We planned to reconstruct the lower extremity defect with a free flap, but the vessel status was severely compromised intraoperatively. Thus, we found the anterior tibial artery perforator using Doppler ultrasound, elevated the tibialis anterior muscle segment flap, and transposed it to cover the defect successfully. The flap presented with a nice contour and the skin graft covering the flap survived completely. There were no complications of the surgical site at three months follow-up and no gait morbidity. This is a meaningful case applying the concept of segmental muscle flap based on a perforator that had advantages including proper bulkiness, vascularization, and preservation of function, which were well applied, leading to great success.