Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to Evaluate Cardiac Function in Children with Repaired Tetralogy of Fallot

  • YaFeng Peng;XinYu Su;LiWei Hu;Qian Wang;RongZhen Ouyang;AiMin Sun;Chen Guo;XiaoFen Yao;Yong Zhang;LiJia Wang;YuMin Zhong
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1525-1536
    • /
    • 2021
  • Objective: To investigate the feasibility of cine three-dimensional (3D) balanced steady-state free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for image denoising in evaluating cardiac function in children with repaired tetralogy of Fallot (rTOF). Materials and Methods: Thirty-five patients with rTOF (mean age, 12 years; range, 7-18 years) were enrolled to undergo cardiac cine image acquisition, including two-dimensional (2D) b-SSFP, 3D b-SSFP, and 3D b-SSFP combined with NLM. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) of the two ventricles were measured and indexed by body surface index. Acquisition time and image quality were recorded and compared among the three imaging sequences. Results: 3D b-SSFP with denoising vs. 2D b-SSFP had high correlation coefficients for EDV, ESV, SV, and EF of the left (0.959-0.991; p < 0.001) as well as right (0.755-0.965; p < 0.001) ventricular metrics. The image acquisition time ± standard deviation (SD) was 25.1 ± 2.4 seconds for 3D b-SSFP compared with 277.6 ± 0.7 seconds for 2D b-SSFP, indicating a significantly shorter time with the 3D than the 2D sequence (p < 0.001). Image quality score was better with 3D b-SSFP combined with denoising than with 3D b-SSFP (mean ± SD, 3.8 ± 0.6 vs. 3.5 ± 0.6; p = 0.005). Signal-to-noise ratios for blood and myocardium as well as contrast between blood and myocardium were higher for 3D b-SSFP combined with denoising than for 3D b-SSFP (p < 0.05 for all but septal myocardium). Conclusion: The 3D b-SSFP sequence can significantly reduce acquisition time compared to the 2D b-SSFP sequence for cine imaging in the evaluation of ventricular function in children with rTOF, and its quality can be further improved by combining it with an NLM denoising method.

Novel Resectable Myocardial Model Using Hybrid Three-Dimensional Printing and Silicone Molding for Mock Myectomy for Apical Hypertrophic Cardiomyopathy

  • Wooil Kim;Minje Lim;You Joung Jang;Hyun Jung Koo;Joon-Won Kang;Sung-Ho Jung;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1054-1065
    • /
    • 2021
  • Objective: We implemented a novel resectable myocardial model for mock myectomy using a hybrid method of three-dimensional (3D) printing and silicone molding for patients with apical hypertrophic cardiomyopathy (ApHCM). Materials and Methods: From January 2019 through May 2020, 3D models from three patients with ApHCM were generated using the end-diastolic cardiac CT phase image. After computer-aided designing of measures to prevent structural deformation during silicone injection into molding, 3D printing was performed to reproduce anatomic details and molds for the left ventricular (LV) myocardial mass. We compared the myocardial thickness of each cardiac segment and the LV myocardial mass and cavity volumes between the myocardial model images and cardiac CT images. The surgeon performed mock surgery, and we compared the volume and weight of the resected silicone and myocardium. Results: During the mock surgery, the surgeon could determine an ideal site for the incision and the optimal extent of myocardial resection. The mean differences in the measured myocardial thickness of the model (0.3, 1.0, 6.9, and 7.3 mm in the basal, midventricular, apical segments, and apex, respectively) and volume of the LV myocardial mass and chamber (36.9 mL and 14.8 mL, 2.9 mL and -9.4 mL, and 6.0 mL and -3.0 mL in basal, mid-ventricular and apical segments, respectively) were consistent with cardiac CT. The volume and weight of the resected silicone were similar to those of the resected myocardium (6 mL [6.2 g] of silicone and 5 mL [5.3 g] of the myocardium in patient 2; 12 mL [12.5 g] of silicone and 11.2 mL [11.8 g] of the myocardium in patient 3). Conclusion: Our 3D model created using hybrid 3D printing and silicone molding may be useful for determining the extent of surgery and planning surgery guided by a rehearsal platform for ApHCM.

Recovery Trajectory in Tachycardia Induced Heart Failure Model (빈맥을 이용한 심부전 모델에서 회복궤도)

  • 오중환;박승일;원준호;김은기;이종국
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.422-427
    • /
    • 1999
  • Background: Tachycardia induced heart failure model would be the model of choice for the dilated cardiomyopathy. This more closely resembles the clinical syndrome and does not require major surgical trauma, myocardial ischemia and pharmacological or toxic depression of cardiac function. When heart failure is progressive, application of new surgical procedures to the faling heart is highly risky. It has been shown that recovery trajectory from heart failure is a new method in decreasing animal mortality. The purpose is to establish the control datas for recovery trajectory in the canine heart failure model. Material and Method: 21 mongrel dogs were studied at 4 stages(baseline, at the heart failure, 4 and 8 weeks after recovery). Heart failure was induced during 4 weeks of continuous rapid pacing using a pacemaker. Eight weeks of trajectory of recovery period was allowed. Indices of left ventricular function and dimension were measured every 2 weeks and the hemodynamics were measured by use of Swan-Ganz catheterization and thermodilution method every 4 weeks. Values were expressed as mean${\pm}$standard deviation. Result: 4(20%) dogs died due to heart failure. Left ventricular end-diastolic volume at the 4 stages were 40.8${\pm}$7.4, 82.1${\pm}$21.1, 59.9${\pm}$7.7 and 46.5${\pm}$6.5ml. Left ventricular end-systolic volume showed the same trend. Ejection fractions were 50.6${\pm}$4.1, 17.5${\pm}$5.8, 36.3${\pm}$7.3, and 41.5${\pm}$2.4%. Blood pressure and heart rate showed no significant changes. Pressures of central vein, right ventricle, pulmonary artery, and pulmonary capillary wedge showed significant increase during the heart failure period, normalizing at the end of recovery period. Stroke volumes were 21.5${\pm}$8.2, 12.3${\pm}$3.5, 17.9${\pm}$4.6, and 15.5${\pm}$3.4ml. Blood norepinephrine level was 133.3${\pm}$60.0pg/dL at the baseline and 479.4${\pm}$327.3pg/dL at the heart failure stage(p=0.008). Conclusion: Development of tachycardia induced heart failure model is of high priority due to ready availability and reasonable amenability to measurements. Recovery trajectory after cessation of tachycardia showed reduction of cardiac dilatation and heart function. Application of new surgical procedures during the recovery period could decrease animal mortality.

  • PDF

Evaluation of short-term cardiac function by tissue Doppler imaging in pre and postoperative period of congenital heart disease (조직 도플러 영상을 이용한 선천성 심장병 수술 전후의 단기 심기능 평가)

  • Lee, Jun-Hwa;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.476-483
    • /
    • 2007
  • Purpose : The objective of this study was to assess ventricular function by tissue Doppler imaging (TDI) in children with congenital heart disease (CHD) who have been undergoing open heart surgery (OHS) using cardiopulmonary bypass. We tried to compare the parameters of tissue Doppler imaging before and after OHS in patients with congenital heart disease. Methods : This study was conducted on 32 patients with CHD after OHS from January 2005 to December 2005 at Kyungpook National University hospital. Patients who underwent 2-D echocardiography before and after their OHS. All patients were divided into three groups, left ventricular volume overloading group (group 1), and right ventricular volume overloading group (group 2), and right ventricular pressure overloading group (group 3). The TDIs were examined before and 1 to 3 months after OHS. Peak early diastolic (E), and peak late diastolic (A) velocity of transmitral flow were measured by pulsed wave Doppler examination. Peak systolic (Sm), peak early diastolic (Em), and peak late diastolic (Am) velocity in apical 4-chamber and 2-chamber views were measured by TDI. The author calculated E/Em ratio. Results : The patients were 14 boys and 18 girls and the average age of patients was 2 years and 3 months. The congenital heart diseases which have to get OHS were ventricular septal defect (13 cases), atrial septal defect (7), atrioventricular septal defect (3), isolated pulmonary stenosis (2) and tetralogy of Fallot (7). There were significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view (P<0.05). Conclusion : This study showed significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view after OHS. These changes might be due to the effects of cardiopulmonary bypass in OHS and/or hemodynamic changes after correction of congenital heart disease. To clarify these changes, further study on more patients is needed.

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

Numerical Study of Effect of counter-pulsation on Hemodynamic Response in the ECLS (체외생명구조장치에서 역박동 방법이 혈류역학 응답에 미치는 영향에 대한 수치적 연구)

  • Kim, In-Su;Lim, Ki-Moo;Choi, Seoung-Wook;Jun, Hyung-Min;Shim, Eun-Bo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1660-1664
    • /
    • 2008
  • Extra-corporeal Life Support System (ECLS) is the device used in emergency cases to substitute a extracorporeal circulation in open heart surgery, cardiac arrest or in acute cardiopulmonary failure. To obtain the effect of counter-pulsation on hemodynamic response in the ECLS quantitatively, we developed cardiovascular model which consists of 12 compartment model of heldt et al. and 3 compartment model of Schreiner et al. based on windkessel approximation. We compared coronary perfusion, arterial pulse pressure, cardiac output, and left ventricular pressure-volume diagram according to flow configuration such as counter-pulsation, copulsation, and continous flow. When counter-pulsation was applied, 5% higher coronary perfusion, 26% lower pulse pressure, and 2% higher cardiac output than copulsation condition were calculated. We conclude that counter-pulsation configuration in the ECLS is hemodynamically more stable than copulsation and influences the positive effect to recover ventricles.

  • PDF

Study on Electrically Powered Left Ventricular Circulation Assist Device (좌심실 전동순환 보조장치에 관한 연구)

  • Kim, Myoung-Nam;Lee, Jeong-Woo;Chang, Bong-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • This paper outlines the development of a non-pulsatile axial flow type blood pump control system. By utilizing blood pressure and heart rate, this system can assist the left ventricle in controlling blood pressure and blood volume. The system is comprised of a blood pump, signal sensor, signal interface, and signal-processing component. A control algorithm is also proposed which can control non-pulsatile, continuous blood flow in the human circulatory system. To facilitate the control required for non-pulsatile blood pump in a physiological system, an experimental control rule was developed utilizing ECG and blood pressure data, both of which are easily detectable variables in the body. The system was then tested using a mock-up circulation system and we found that it is possible that this systems could be temporarily used in clinic.

  • PDF

The Impact of Right Atrial Size to Predict Success of Direct Current Cardioversion in Patients With Persistent Atrial Fibrillation

  • Christoph Doring;Utz Richter;Stefan Ulbrich;Carsten Wunderlich;Micaela Ebert;Sergio Richter;Axel Linke;Krunoslav Michael Sveric
    • Korean Circulation Journal
    • /
    • v.53 no.5
    • /
    • pp.331-343
    • /
    • 2023
  • Background and Objectives: The prognostic implication of right atrial (RA) and left atrial (LA) size for an immediate success of direct current cardioversion (DCCV) in atrial fibrillation (AF) remains unclear. This study aimed to compare RA and LA size for the prediction of DCCV success. Methods: Between 2012 and 2018, 734 consecutive outpatients were screened for our prospective registry. Each eligible patient received a medical history, blood analysis, and transthoracic echocardiography with a focus on indexed RA (iRA) area and LA volume (iLAV) prior to DCCV with up to three biphasic shocks (200-300-360 J) or additional administration of amiodarone or flecainide to restore sinus rhythm. Results: We enrolled 589 patients, and DCCV was in 89% (n=523) successful. Mean age was 68 ± 10 years, and 40% (n=234) had New York heart association class >II. A prevalence of the male sex (64%, n=376) and of persistent AF (86%, n=505) was observed. Although DCCV success was associated with female sex (odds ratio [OR], 1.88; 95% confidence interval [CI], 1.06-3.65), with absence of coronary heart disease and normal left ventricular function (OR, 2.24; 95% CI, 1.26-4.25), with short AF duration (OR, 1.93; 95% CI, 1.05-4.04) in univariable regression, only iRA area remained a stable and independent predictor of DCCV success (OR, 0.27; 95% CI, 0.12-0.69; area under the curve 0.71), but not iLAV size (OR, 1.16; 95% CI, 1.05-1.56) in multivariable analysis. Conclusions: iRA area is superior to iLAV for the prediction of immediate DCCV success in AF.

Echocardiographic Parameters of Pulmonary Atresia with Intact Ventricular Septum(PA/IVS) (심실 중격 결손을 동반하지 않은 폐동맥 폐쇄 환아에서의 심초음파 계측치)

  • Lee, Young Seok;Kim, Yeo Hyang;Hyum, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.484-489
    • /
    • 2003
  • Purpose : To understand morphologic and hemodynamic variations in patients with pulmonary atresia with intact ventricular septum(PA/IVS), and to decide the best treatment modalities, we measured right ventricular volume, inflow, and outflow valvular annulus size in these patients and compared them with those of normal newborns. Methods : Eight patients with PA/IVS diagnosed by echocardiography from January to December 2001 were enrolled in this study. Among the total eight patients, five were male and three were female. The mean age of patients was 6.9 days(1-34 days), and the mean body weight was 3,343 gm (2,970-4,000 gm). Ten fullterm newborn infants with sepsis or hyperbilirubinemia without heart disease were enrolled as a control group. Echocardiographic and Doppler studies using Acuson Aspen (7Mh probe) were recorded on super-VHS videotape and later on, with review mode. We measured volumes of right and left ventricles, aortic, pulmonic, mitral and tricuspid valvular annulus sizes using an installed program, and then these parameters were compared with those of the control group. Results : Mean Z-value of tricuspid valvular annulus in PA/IVS was $-3.69{\pm}2.80$(-8.4--0.45), and tricuspid/mitral valvular annulus size ratio $0.68{\pm}0.15$(0.43--0.84). The more the tricuspid/mitral valvular annulus size ratio, the more Z-value of tricuspid valvular annulus(P=0.003, r=0.885). Those patients who underwent pulmonary valvuloplasty(balloon or surgical) had a tendency toward larger volume of the right ventricle, more Z-value of pulmonic and tricuspid valvular annulus, and more tricuspid/mitral valvular annulus size ratio than those patients who underwent a shunt operation. Conclusion : Compared to a measurement of the volume of the right ventricle, measurements of tricuspid/mitral valvular annulus size ratio and Z-value of tricuspid valvular annulus may be easier and better parameters to decide the treatment method and to predict prognosis in PA/IVS patients.

A Study on the Estimation of Regional Myocardial Blood Flow in Experimental Canine Model with Coronary Thrombosis using Rb-82 Dynamic Myocardial Positron Emission Tomography (실험 개에서 Rb-82 심근 Dynamic PET 영상을 이용한 국소 심근 혈류 예측의 기본 모델 연구)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Keon-Wook;Hwang, Eun-Kyung;Jeong, Jae-Min;Chang, Kee-Hyun;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.48-53
    • /
    • 1995
  • This study investigates a simple mathematical model for the quantitative estimation of regional myocardial blood flow in experimental canine coronary artery thrombosis using Rb-82 dynamic myocardial positron emission tomography. The coronary thrombosis was induced using the new catheter technique by narrowing the lumen of coronary vessel gradually, which finally led to partial obstruction of coronary artery. Ten Rb-82 dynamic myocardial PET scans were performed sequentially for each experiment using our 5, 10 and 20 second acquisition protocol, respectively, and three regions of interest were drawn on the transaxial slices, one on left ventricular chamber for input function and the other two on normal and decreased perfusion segments for the flow estimation in those regions. Single compartment model has been applied to the measured sets of regional PET data, and the rate constants of influx to myocardial tissue were calculated for regional myocardial flow estimates with the three parameter fits of raw data by the Levenberg-Marquardt method. The results showed that, (1) single compartment model suggested by Kety-Schmidt could be used for the simple estimation of regional myocardial blood flow, (2) the calculated regional myocardial blood flow estimates were dependent on the selection of input function, which reflected partial volume effect and left ventricular wall motion, and (3) mathematically fitted input and tissue time activity curves were more suitable than the direct application of the measured data in terms of convergence.

  • PDF