• Title/Summary/Keyword: Left ventricular rotation

Search Result 4, Processing Time 0.019 seconds

Surgical Correction of Partial Atrioventricular Canal: One Case Report (부분방실관의 교정수술 치험 1예)

  • 이철범
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.49-59
    • /
    • 1981
  • This is one case report of surgically treated partial atrioventricular canal. The 22 year-old male patient had no definitive history of frequent respiratory infection and cyanosis in his early childhood. Since his age of 7 years, dyspnea was manifested on exertion. First appearance of congestive heart failure was at his age of 16 years old. The physical examination revealed that the neck veins were distended and heaving of precordium. A thrill was palpable on the left 3rd-4th intercostal space extending from the sternal border toward the apex and Grade IV/VI systolic ejection murmur was audible on it. Neither cyanosis nor clubbing was noted. Liver was palpable about 5 finger breadths. Chest X-ray revealed increased pulmonary vascularity and severe cardiomegaly (C-T ratio = 74%). EKG revealed LAD, clockwise rotation, LVH and trifascicular block. Echocardiogram showed paradoxical ventricular septal movement, narrowed left ventricular outflow tract and abnormal diastolic movement of the anterior leaflet of mitral valve. Right heart catheterization resulted in large left to right shunt (Qp : Qs = 5.7: 1), ASD and moderate pulfllonary hypertension. Finally, left ventriculogram revealed typical goose neck appearance of left ventrlcalar outflow tract. On Oct. 10, 1980, open heart surgery was performed. Operative findings were: 1. Large primum defect ($6{\times}5$ Cm in diameter) 2. Cleft on the anterior leaflet of mitral valve. 3. The upper portion of ventricular septum was descent but no interventricular communication. 4. Downward attachment of the atrioventricular valves on the ventricular muscular septum. 5. Medium sized secumdum defect ($2{\times}1$ Cm in diameter). The cleft was repaired with 4 interrupted sutures. The primum defect was closed with Teflon patch and the secundum defect was closed with direct suture closure. Postoperatively atrial flutter-fibrillation in EKG and Grade U/VI apical systolic murmur were found. The postoperative course was uneventful and discharged on 29th postoperative day in good general conditions.

  • PDF

Double Outlet of Right Ventricle in Criss-Cross Heart -Surgical Experience of One Case (십자형심장에 동반된 양대혈관우심실기시증 -수술치험 1례)

  • Kim, Dae-Yeon;Jo, Seong-Rae;Park, Seong-Dal;Jeong, Hyeon-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1242-1246
    • /
    • 1997
  • Criss-cross heart which is a cardiac malformation caused by abnormal rotation of the ventricles early in embryonic development, is rare but a double outlet of right ventricle in priss-cross heart is very rare. We experienced a case of criss-cross heart which is situs solidus, concordant atrioventricular connection and double outlet of rig t ventricle with remote ventricular septal defect of perimembranous inlet type. A 4-years old female was diagnosed as a double outlet of right ventricle in criss-cross heart after echocardiography, cardiac catheterization and cardiac angiography. The surgical correction was a intraventricular reconstruction of left ventricular outflow with 314 circle of 20 mm Hemashield vascular graft from the ventricular septal defect to the aorta. The patient had a temporary atrioventricular block but was recovered uneventfully, and a postoperative echocardiogram showed no left ventricular outflow obstruction, no intracardiac shunt.

  • PDF

Successful Modified Nikaidoh Procedure (Pivot Rotation) in a Patient with Double Outlet Right Ventricle and Pulmonary Atresia: Case Report

  • Lee, Jae Jun;Lee, Ok Jeong;Yang, Ji-Hyuk;Jun, Tae-Gook
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.389-392
    • /
    • 2021
  • Double outlet right ventricle (DORV) with pulmonary atresia (PA) is an uncommon congenital disease. Because of anatomical and physiological anomalies in the systemic and pulmonary circulation, corrective surgery may be challenging. We present the case of a patient with DORV and PA. This condition was successfully corrected using a modified Nikaidoh procedure, resulting in reduced obstruction of the left ventricular outflow tract.

Quantification of Myocardial Blood flow using Dynamic N-13 Ammonia PET and factor Analysis (N-13 암모니아 PET 동적영상과 인자분석을 이용한 심근 혈류량 정량화)

  • Choi, Yong;Kim, Joon-Young;Im, Ki-Chun;Kim, Jong-Ho;Woo, Sang-Keun;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.316-326
    • /
    • 1999
  • Purpose: We evaluated the feasibility of extracting pure left ventricular blood pool and myocardial time-activity curves (TACs) and of generating factor images from human dynamic N-13 ammonia PET using factor analysis. The myocardial blood flow (MBF) estimates obtained with factor analysis were compared with those obtained with the user drawn region-of-interest (ROI) method. Materials and Methods: Stress and rest N-13 ammonia cardiac PET imaging was acquired for 23 min in 5 patients with coronary artery disease using GE Advance tomograph. Factor analysis generated physiological TACs and factor images using the normalized TACs from each dixel. Four steps were involved in this algorithm: (a) data preprocessing; (b) principal component analysis; (c) oblique rotation with positivity constraints; (d) factor image computation. Area under curves and MBF estimated using the two compartment N-13 ammonia model were used to validate the accuracy of the factor analysis generated physiological TACs. The MBF estimated by factor analysis was compared to the values estimated by using the ROI method. Results: MBF values obtained by factor analysis were linearly correlated with MBF obtained by the ROI method (slope = 0.84, r = 0.91), Left ventricular blood pool TACs obtained by the two methods agreed well (Area under curve ratio: 1.02 ($0{\sim}1min$), 0.98 ($0{\sim}2min$), 0.86 ($1{\sim}2min$)). Conclusion: The results of this study demonstrates that MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and factor analysis. This method is simple and accurate, and can measure MBF without blood sampling, ROI definition or spillover correction.

  • PDF